diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h
index 81392d96bb..4e39703ad4 100644
--- a/Marlin/Configuration.h
+++ b/Marlin/Configuration.h
@@ -680,7 +680,7 @@ const bool Z_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the logic
 
 // The RepRapDiscount Smart Controller (white PCB)
 // http://reprap.org/wiki/RepRapDiscount_Smart_Controller
-#define REPRAP_DISCOUNT_SMART_CONTROLLER
+//#define REPRAP_DISCOUNT_SMART_CONTROLLER
 
 // The GADGETS3D G3D LCD/SD Controller (blue PCB)
 // http://reprap.org/wiki/RAMPS_1.3/1.4_GADGETS3D_Shield_with_Panel
@@ -791,13 +791,13 @@ const bool Z_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the logic
 // Uncomment below to enable
 //#define FILAMENT_SENSOR
 
-#define FILAMENT_SENSOR_EXTRUDER_NUM	0  //The number of the extruder that has the filament sensor (0,1,2)
-#define MEASUREMENT_DELAY_CM			14  //measurement delay in cm.  This is the distance from filament sensor to middle of barrel
+#define FILAMENT_SENSOR_EXTRUDER_NUM 0   //The number of the extruder that has the filament sensor (0,1,2)
+#define MEASUREMENT_DELAY_CM        14   //measurement delay in cm.  This is the distance from filament sensor to middle of barrel
 
-#define DEFAULT_NOMINAL_FILAMENT_DIA  3.0  //Enter the diameter (in mm) of the filament generally used (3.0 mm or 1.75 mm) - this is then used in the slicer software.  Used for sensor reading validation
-#define MEASURED_UPPER_LIMIT          3.30  //upper limit factor used for sensor reading validation in mm
-#define MEASURED_LOWER_LIMIT          1.90  //lower limit factor for sensor reading validation in mm
-#define MAX_MEASUREMENT_DELAY			20  //delay buffer size in bytes (1 byte = 1cm)- limits maximum measurement delay allowable (must be larger than MEASUREMENT_DELAY_CM  and lower number saves RAM)
+#define DEFAULT_NOMINAL_FILAMENT_DIA 3.0 //Enter the diameter (in mm) of the filament generally used (3.0 mm or 1.75 mm) - this is then used in the slicer software.  Used for sensor reading validation
+#define MEASURED_UPPER_LIMIT         3.3 //upper limit factor used for sensor reading validation in mm
+#define MEASURED_LOWER_LIMIT         1.9 //lower limit factor for sensor reading validation in mm
+#define MAX_MEASUREMENT_DELAY       20   //delay buffer size in bytes (1 byte = 1cm)- limits maximum measurement delay allowable (must be larger than MEASUREMENT_DELAY_CM  and lower number saves RAM)
 
 //defines used in the code
 #define DEFAULT_MEASURED_FILAMENT_DIA  DEFAULT_NOMINAL_FILAMENT_DIA  //set measured to nominal initially