[2.0.x] Fix Anycubic Kossel with Probe V1, stuck LCD message after stow (#11929)
This commit is contained in:
parent
dc11131656
commit
0b602ae101
@ -668,15 +668,11 @@
|
||||
// Mechanical endstop with COM to ground and NC to Signal uses "false" here (most common setup).
|
||||
#define X_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Y_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Z_MIN_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
|
||||
#define Z_MIN_ENDSTOP_INVERTING (ANYCUBIC_PROBE_VERSION + 0 == 2) // V1 is NC, V2 is NO
|
||||
#define X_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Y_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#if ANYCUBIC_PROBE_VERSION == 1
|
||||
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // V1 Probe is NC
|
||||
#elif ANYCUBIC_PROBE_VERSION == 2
|
||||
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // V2 Probe is NO
|
||||
#endif
|
||||
#define Z_MIN_PROBE_ENDSTOP_INVERTING Z_MIN_ENDSTOP_INVERTING
|
||||
|
||||
/**
|
||||
* Stepper Drivers
|
||||
|
@ -431,7 +431,7 @@ bool set_probe_deployed(const bool deploy) {
|
||||
BUZZ(100, 698);
|
||||
|
||||
const char * const ds_str = deploy ? PSTR(MSG_MANUAL_DEPLOY) : PSTR(MSG_MANUAL_STOW);
|
||||
lcd_setalertstatusPGM(ds_str);
|
||||
lcd_setstatusPGM(ds_str);
|
||||
serialprintPGM(ds_str);
|
||||