Merge pull request #3277 from jbrazio/bugfix/m190-temp-never-reached

M190 bed temp is never reached
This commit is contained in:
Scott Lahteine 2016-03-29 18:28:51 -07:00
commit 12c0bf9521

View File

@ -4320,7 +4320,7 @@ inline void gcode_M109() {
cancel_heatup = false;
millis_t now = millis(), next_temp_ms = now + 1000UL;
while (!cancel_heatup && degTargetBed() != degBed()) {
while (!cancel_heatup && fabs(degTargetBed() - degBed()) < 0.75f) {
millis_t now = millis();
if (now > next_temp_ms) { //Print Temp Reading every 1 second while heating up.
next_temp_ms = now + 1000UL;