mirror of
https://github.com/MarlinFirmware/Marlin.git
synced 2024-11-23 12:04:19 +00:00
Combine thermal runaway and watch-period
- Make thermal protection for all hotends and/or bed into simple switches - Now enable `WATCH_TEMP_PERIOD` when `THERMAL_PROTECTION_HOTENDS` is enabled - Move detailed thermal parameters to `Configuration_adv.h` - Add sanity checks to warn about old configurations - Change `WATCH_TEMP_PERIOD` to seconds instead of milliseconds
This commit is contained in:
parent
4097207c75
commit
2445ae3d3a
@ -284,24 +284,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,15 +15,26 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
@ -34,14 +45,16 @@
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|
||||
//automatic temperature: The hot end target temperature is calculated by all the buffered lines of gcode.
|
||||
//The maximum buffered steps/sec of the extruder motor are called "se".
|
||||
//You enter the autotemp mode by a M109 S<mintemp> B<maxtemp> F<factor>
|
||||
// the target temperature is set to mintemp+factor*se[steps/sec] and limited by mintemp and maxtemp
|
||||
// you exit the value by any M109 without F*
|
||||
// Also, if the temperature is set to a value <mintemp, it is not changed by autotemp.
|
||||
// on an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#define AUTOTEMP
|
||||
#ifdef AUTOTEMP
|
||||
#define AUTOTEMP_OLDWEIGHT 0.98
|
||||
|
@ -3167,7 +3167,7 @@ inline void gcode_M104() {
|
||||
setTargetHotend1(temp == 0.0 ? 0.0 : temp + duplicate_extruder_temp_offset);
|
||||
#endif
|
||||
|
||||
#ifdef WATCH_TEMP_PERIOD
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
start_watching_heater(target_extruder);
|
||||
#endif
|
||||
}
|
||||
@ -3281,7 +3281,7 @@ inline void gcode_M109() {
|
||||
if (code_seen('B')) autotemp_max = code_value();
|
||||
#endif
|
||||
|
||||
#ifdef WATCH_TEMP_PERIOD
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
start_watching_heater(target_extruder);
|
||||
#endif
|
||||
|
||||
|
@ -313,4 +313,16 @@
|
||||
#error [XYZ]_HOME_RETRACT_MM settings have been renamed [XYZ]_HOME_BUMP_MM
|
||||
#endif
|
||||
|
||||
#if WATCH_TEMP_PERIOD > 500
|
||||
#error WATCH_TEMP_PERIOD now uses seconds instead of milliseconds
|
||||
#endif
|
||||
|
||||
#if !defined(THERMAL_PROTECTION_HOTENDS) && (defined(WATCH_TEMP_PERIOD) || defined(THERMAL_PROTECTION_PERIOD))
|
||||
#error Thermal Runaway Protection for hotends must now be enabled with THERMAL_PROTECTION_HOTENDS
|
||||
#endif
|
||||
|
||||
#if !defined(THERMAL_PROTECTION_BED) && defined(THERMAL_PROTECTION_BED_PERIOD)
|
||||
#error Thermal Runaway Protection for the bed must now be enabled with THERMAL_PROTECTION_BED
|
||||
#error
|
||||
|
||||
#endif //SANITYCHECK_H
|
||||
|
@ -284,23 +284,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -250,23 +250,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -250,23 +250,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -271,23 +271,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -300,23 +300,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -200,8 +200,7 @@ Here are some standard links for getting your machine calibrated:
|
||||
// is more then PID_FUNCTIONAL_RANGE then the PID will be shut off and the heater will be set to min/max.
|
||||
#define PID_INTEGRAL_DRIVE_MAX PID_MAX //limit for the integral term
|
||||
#define K1 0.95 //smoothing factor within the PID
|
||||
#define PID_dT ((16.0 * 8.0)/(F_CPU / 64.0 / 256.0)) //sampling period of the temperature routine
|
||||
|
||||
|
||||
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
|
||||
// Ultimaker
|
||||
#define DEFAULT_Kp 22.2
|
||||
@ -271,44 +270,24 @@ Here are some standard links for getting your machine calibrated:
|
||||
#define EXTRUDE_MAXLENGTH (X_MAX_LENGTH+Y_MAX_LENGTH) //prevent extrusion of very large distances.
|
||||
|
||||
//===========================================================================
|
||||
//============================= Thermal Runaway Protection ==================
|
||||
//======================== Thermal Runaway Protection =======================
|
||||
//===========================================================================
|
||||
/*
|
||||
This is a feature to protect your printer from burn up in flames if it has
|
||||
a thermistor coming off place (this happened to a friend of mine recently and
|
||||
motivated me writing this feature).
|
||||
|
||||
The issue: If a thermistor come off, it will read a lower temperature than actual.
|
||||
The system will turn the heater on forever, burning up the filament and anything
|
||||
else around.
|
||||
|
||||
After the temperature reaches the target for the first time, this feature will
|
||||
start measuring for how long the current temperature stays below the target
|
||||
minus _HYSTERESIS (set_temperature - THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).
|
||||
|
||||
If it stays longer than _PERIOD, it means the thermistor temperature
|
||||
cannot catch up with the target, so something *may be* wrong. Then, to be on the
|
||||
safe side, the system will he halt.
|
||||
|
||||
Bear in mind the count down will just start AFTER the first time the
|
||||
thermistor temperature is over the target, so you will have no problem if
|
||||
your extruder heater takes 2 minutes to hit the target on heating.
|
||||
|
||||
*/
|
||||
// If you want to enable this feature for all your extruder heaters,
|
||||
// uncomment the 2 defines below:
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 //in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// If you want to enable this feature for your bed heater,
|
||||
// uncomment the 2 defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 //in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
/**
|
||||
* Thermal Runaway Protection protects your printer from damage and fire if a
|
||||
* thermistor falls out or temperature sensors fail in any way.
|
||||
*
|
||||
* The issue: If a thermistor falls out or a temperature sensor fails,
|
||||
* Marlin can no longer sense the actual temperature. Since a disconnected
|
||||
* thermistor reads as a low temperature, the firmware will keep the heater on.
|
||||
*
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*/
|
||||
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
@ -412,17 +391,20 @@ const bool Z_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the logic
|
||||
#define Z_MAX_POS 200
|
||||
|
||||
//===========================================================================
|
||||
//============================= Filament Runout Sensor ======================
|
||||
//========================= Filament Runout Sensor ==========================
|
||||
//===========================================================================
|
||||
//#define FILAMENT_RUNOUT_SENSOR // Uncomment for defining a filament runout sensor such as a mechanical or opto endstop to check the existence of filament
|
||||
// In RAMPS uses servo pin 2. Can be changed in pins file. For other boards pin definition should be made.
|
||||
// It is assumed that when logic high = filament available
|
||||
// when logic low = filament ran out
|
||||
//const bool FIL_RUNOUT_INVERTING = true; // Should be uncommented and true or false should assigned
|
||||
//#define ENDSTOPPULLUP_FIL_RUNOUT // Uncomment to use internal pullup for filament runout pins if the sensor is defined.
|
||||
#ifdef FILAMENT_RUNOUT_SENSOR
|
||||
const bool FIL_RUNOUT_INVERTING = true; // Should be uncommented and true or false should assigned
|
||||
#define ENDSTOPPULLUP_FIL_RUNOUT // Uncomment to use internal pullup for filament runout pins if the sensor is defined.
|
||||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
//===========================================================================
|
||||
//============================ Mesh Bed Leveling ============================
|
||||
//=========================== Manual Bed Leveling ===========================
|
||||
//===========================================================================
|
||||
|
||||
// #define MANUAL_BED_LEVELING // Add display menu option for bed leveling
|
||||
@ -443,7 +425,7 @@ const bool Z_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the logic
|
||||
#endif // MESH_BED_LEVELING
|
||||
|
||||
//===========================================================================
|
||||
//============================= Bed Auto Leveling ===========================
|
||||
//============================ Bed Auto Leveling ============================
|
||||
//===========================================================================
|
||||
|
||||
// @section bedlevel
|
||||
|
@ -302,23 +302,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 3000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -270,23 +270,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -300,23 +300,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 120 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 4 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 120 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -300,23 +300,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -300,23 +300,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -270,23 +270,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -272,23 +272,10 @@ Here are some standard links for getting your machine calibrated:
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
*
|
||||
* Note that because the countdown starts only AFTER the temperature reaches
|
||||
* the target, this will not catch a thermistor that is already disconnected
|
||||
* when the print starts!
|
||||
*
|
||||
* To enable for all extruder heaters, uncomment the two defines below:
|
||||
*/
|
||||
|
||||
// Parameters for all extruder heaters
|
||||
#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
||||
|
||||
// To enable for the bed heater, uncomment the two defines below:
|
||||
|
||||
// Parameters for the bed heater
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 // in seconds
|
||||
#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
#define THERMAL_PROTECTION_BED // Enable thermal protection for the heated bed
|
||||
|
||||
//===========================================================================
|
||||
//============================= Mechanical Settings =========================
|
||||
|
@ -15,16 +15,37 @@
|
||||
#define BED_CHECK_INTERVAL 5000 //ms between checks in bang-bang control
|
||||
|
||||
/**
|
||||
* Heating Sanity Check
|
||||
*
|
||||
* Whenever an M104 or M109 increases the target temperature this will wait for WATCH_TEMP_PERIOD milliseconds,
|
||||
* and if the temperature hasn't increased by WATCH_TEMP_INCREASE degrees, the machine is halted, requiring a
|
||||
* hard reset. This test restarts with any M104/M109, but only if the current temperature is below the target
|
||||
* by at least 2 * WATCH_TEMP_INCREASE degrees celsius.
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16000 // 16 seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Heat up at least 4 degrees in 16 seconds
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Whenever an M104 or M109 increases the target temperature the firmware will wait for the
|
||||
* WATCH_TEMP_PERIOD to transpire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is below the target by at least 2 * WATCH_TEMP_INCREASE degrees.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#ifdef THERMAL_PROTECTION_BED
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Automatic Temperature:
|
||||
* The hotend target temperature is calculated by all the buffered lines of gcode.
|
||||
* The maximum buffered steps/sec of the extruder motor is called "se".
|
||||
* Start autotemp mode with M109 S<mintemp> B<maxtemp> F<factor>
|
||||
* The target temperature is set to mintemp+factor*se[steps/sec] and is limited by
|
||||
* mintemp and maxtemp. Turn this off by excuting M109 without F*
|
||||
* Also, if the temperature is set to a value below mintemp, it will not be changed by autotemp.
|
||||
* On an Ultimaker, some initial testing worked with M109 S215 B260 F1 in the start.gcode
|
||||
*/
|
||||
#ifdef PIDTEMP
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
@ -73,16 +73,14 @@ unsigned char soft_pwm_bed;
|
||||
int current_raw_filwidth = 0; //Holds measured filament diameter - one extruder only
|
||||
#endif
|
||||
|
||||
#define HAS_HEATER_THERMAL_PROTECTION (defined(THERMAL_RUNAWAY_PROTECTION_PERIOD) && THERMAL_RUNAWAY_PROTECTION_PERIOD > 0)
|
||||
#define HAS_BED_THERMAL_PROTECTION (defined(THERMAL_RUNAWAY_PROTECTION_BED_PERIOD) && THERMAL_RUNAWAY_PROTECTION_BED_PERIOD > 0 && TEMP_SENSOR_BED != 0)
|
||||
#if HAS_HEATER_THERMAL_PROTECTION || HAS_BED_THERMAL_PROTECTION
|
||||
#if THERMAL_PROTECTION_HOTENDS || THERMAL_PROTECTION_BED
|
||||
enum TRState { TRReset, TRInactive, TRFirstHeating, TRStable, TRRunaway };
|
||||
void thermal_runaway_protection(TRState *state, millis_t *timer, float temperature, float target_temperature, int heater_id, int period_seconds, int hysteresis_degc);
|
||||
#if HAS_HEATER_THERMAL_PROTECTION
|
||||
#if THERMAL_PROTECTION_HOTENDS
|
||||
static TRState thermal_runaway_state_machine[4] = { TRReset, TRReset, TRReset, TRReset };
|
||||
static millis_t thermal_runaway_timer[4]; // = {0,0,0,0};
|
||||
#endif
|
||||
#if HAS_BED_THERMAL_PROTECTION
|
||||
#if THERMAL_PROTECTION_BED
|
||||
static TRState thermal_runaway_bed_state_machine = TRReset;
|
||||
static millis_t thermal_runaway_bed_timer;
|
||||
#endif
|
||||
@ -170,7 +168,7 @@ static float analog2temp(int raw, uint8_t e);
|
||||
static float analog2tempBed(int raw);
|
||||
static void updateTemperaturesFromRawValues();
|
||||
|
||||
#ifdef WATCH_TEMP_PERIOD
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
int watch_target_temp[EXTRUDERS] = { 0 };
|
||||
millis_t watch_heater_next_ms[EXTRUDERS] = { 0 };
|
||||
#endif
|
||||
@ -604,15 +602,15 @@ void manage_heater() {
|
||||
if (ct < max(HEATER_0_MINTEMP, 0.01)) min_temp_error(0);
|
||||
#endif
|
||||
|
||||
#if defined(WATCH_TEMP_PERIOD) || !defined(PIDTEMPBED) || HAS_AUTO_FAN
|
||||
#if defined(THERMAL_PROTECTION_HOTENDS) || !defined(PIDTEMPBED) || HAS_AUTO_FAN
|
||||
millis_t ms = millis();
|
||||
#endif
|
||||
|
||||
// Loop through all extruders
|
||||
for (int e = 0; e < EXTRUDERS; e++) {
|
||||
|
||||
#if HAS_HEATER_THERMAL_PROTECTION
|
||||
thermal_runaway_protection(&thermal_runaway_state_machine[e], &thermal_runaway_timer[e], current_temperature[e], target_temperature[e], e, THERMAL_RUNAWAY_PROTECTION_PERIOD, THERMAL_RUNAWAY_PROTECTION_HYSTERESIS);
|
||||
#if THERMAL_PROTECTION_HOTENDS
|
||||
thermal_runaway_protection(&thermal_runaway_state_machine[e], &thermal_runaway_timer[e], current_temperature[e], target_temperature[e], e, THERMAL_PROTECTION_PERIOD, THERMAL_PROTECTION_HYSTERESIS);
|
||||
#endif
|
||||
|
||||
float pid_output = get_pid_output(e);
|
||||
@ -621,7 +619,7 @@ void manage_heater() {
|
||||
soft_pwm[e] = current_temperature[e] > minttemp[e] && current_temperature[e] < maxttemp[e] ? (int)pid_output >> 1 : 0;
|
||||
|
||||
// Check if the temperature is failing to increase
|
||||
#ifdef WATCH_TEMP_PERIOD
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
// Is it time to check this extruder's heater?
|
||||
if (watch_heater_next_ms[e] && ms > watch_heater_next_ms[e]) {
|
||||
// Has it failed to increase enough?
|
||||
@ -635,7 +633,7 @@ void manage_heater() {
|
||||
watch_heater_next_ms[e] = 0;
|
||||
}
|
||||
}
|
||||
#endif // WATCH_TEMP_PERIOD
|
||||
#endif // THERMAL_PROTECTION_HOTENDS
|
||||
|
||||
#ifdef TEMP_SENSOR_1_AS_REDUNDANT
|
||||
if (fabs(current_temperature[0] - redundant_temperature) > MAX_REDUNDANT_TEMP_SENSOR_DIFF) {
|
||||
@ -675,8 +673,8 @@ void manage_heater() {
|
||||
|
||||
#if TEMP_SENSOR_BED != 0
|
||||
|
||||
#if HAS_BED_THERMAL_PROTECTION
|
||||
thermal_runaway_protection(&thermal_runaway_bed_state_machine, &thermal_runaway_bed_timer, current_temperature_bed, target_temperature_bed, -1, THERMAL_RUNAWAY_PROTECTION_BED_PERIOD, THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS);
|
||||
#if THERMAL_PROTECTION_BED
|
||||
thermal_runaway_protection(&thermal_runaway_bed_state_machine, &thermal_runaway_bed_timer, current_temperature_bed, target_temperature_bed, -1, THERMAL_PROTECTION_BED_PERIOD, THERMAL_PROTECTION_BED_HYSTERESIS);
|
||||
#endif
|
||||
|
||||
#ifdef PIDTEMPBED
|
||||
@ -999,14 +997,14 @@ void tp_init() {
|
||||
#endif //BED_MAXTEMP
|
||||
}
|
||||
|
||||
#ifdef WATCH_TEMP_PERIOD
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
/**
|
||||
* Start Heating Sanity Check for hotends that are below
|
||||
* their target temperature by a configurable margin.
|
||||
* This is called when the temperature is set. (M104, M109)
|
||||
*/
|
||||
void start_watching_heater(int e) {
|
||||
millis_t ms = millis() + WATCH_TEMP_PERIOD;
|
||||
millis_t ms = millis() + WATCH_TEMP_PERIOD * 1000;
|
||||
if (degHotend(e) < degTargetHotend(e) - (WATCH_TEMP_INCREASE * 2)) {
|
||||
watch_target_temp[e] = degHotend(e) + WATCH_TEMP_INCREASE;
|
||||
watch_heater_next_ms[e] = ms;
|
||||
@ -1016,7 +1014,7 @@ void tp_init() {
|
||||
}
|
||||
#endif
|
||||
|
||||
#if HAS_HEATER_THERMAL_PROTECTION || HAS_BED_THERMAL_PROTECTION
|
||||
#if THERMAL_PROTECTION_HOTENDS || THERMAL_PROTECTION_BED
|
||||
|
||||
void thermal_runaway_protection(TRState *state, millis_t *timer, float temperature, float target_temperature, int heater_id, int period_seconds, int hysteresis_degc) {
|
||||
|
||||
@ -1082,7 +1080,7 @@ void tp_init() {
|
||||
}
|
||||
}
|
||||
|
||||
#endif // HAS_HEATER_THERMAL_PROTECTION || HAS_BED_THERMAL_PROTECTION
|
||||
#endif // THERMAL_PROTECTION_HOTENDS || THERMAL_PROTECTION_BED
|
||||
|
||||
void disable_all_heaters() {
|
||||
for (int i=0; i<EXTRUDERS; i++) setTargetHotend(0, i);
|
||||
|
@ -137,7 +137,7 @@ void PID_autotune(float temp, int extruder, int ncycles);
|
||||
void setExtruderAutoFanState(int pin, bool state);
|
||||
void checkExtruderAutoFans();
|
||||
|
||||
#ifdef WATCH_TEMP_PERIOD
|
||||
#ifdef THERMAL_PROTECTION_HOTENDS
|
||||
void start_watching_heater(int e=0);
|
||||
#endif
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user