mirror of
https://github.com/MarlinFirmware/Marlin.git
synced 2024-11-23 12:04:19 +00:00
Due to the fix for #1248, X and Y probe offsets must not be floats.
The compiler does not support comparing float values: "error: floating constant in preprocessor expression" The loss in X/Y precision shouldn't matter for Z probes, as most microswitches or inductive sensors are larger than 1mm square anyway.
This commit is contained in:
parent
217186d7bc
commit
2701dd8a17
@ -392,6 +392,7 @@ const bool Z_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of
|
||||
|
||||
|
||||
// these are the offsets to the probe relative to the extruder tip (Hotend - Probe)
|
||||
// X and Y offsets must be integers
|
||||
#define X_PROBE_OFFSET_FROM_EXTRUDER -25
|
||||
#define Y_PROBE_OFFSET_FROM_EXTRUDER -29
|
||||
#define Z_PROBE_OFFSET_FROM_EXTRUDER -12.35
|
||||
|
Loading…
Reference in New Issue
Block a user