1
0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2024-11-23 20:18:52 +00:00

Fixed "Cooldown" Selection not reseting bed temp

- enquecommand with multiple lines "\n" doesn't work -> M140 S0 didn't
get processed. So I wrote a new func for the cooldown which uses
setTargetHotend. In addition this does return to status page after
selection.
    - Added setWatch() to preheat-functions (Temperatur sanity check
would never have worked when preheating from the lcd panel)
This commit is contained in:
xifle 2013-05-14 16:56:19 +02:00
parent 90664d20a4
commit 29bb8d7d4f

View File

@ -252,6 +252,7 @@ void lcd_preheat_pla()
setTargetBed(plaPreheatHPBTemp);
fanSpeed = plaPreheatFanSpeed;
lcd_return_to_status();
setWatch(); // heater sanity check timer
}
void lcd_preheat_abs()
@ -262,6 +263,16 @@ void lcd_preheat_abs()
setTargetBed(absPreheatHPBTemp);
fanSpeed = absPreheatFanSpeed;
lcd_return_to_status();
setWatch(); // heater sanity check timer
}
static void lcd_cooldown()
{
setTargetHotend0(0);
setTargetHotend1(0);
setTargetHotend2(0);
setTargetBed(0);
lcd_return_to_status();
}
static void lcd_tune_menu()
@ -299,7 +310,7 @@ static void lcd_prepare_menu()
//MENU_ITEM(gcode, MSG_SET_ORIGIN, PSTR("G92 X0 Y0 Z0"));
MENU_ITEM(function, MSG_PREHEAT_PLA, lcd_preheat_pla);
MENU_ITEM(function, MSG_PREHEAT_ABS, lcd_preheat_abs);
MENU_ITEM(gcode, MSG_COOLDOWN, PSTR("M104 S0\nM140 S0"));
MENU_ITEM(function, MSG_COOLDOWN, lcd_cooldown);
MENU_ITEM(submenu, MSG_MOVE_AXIS, lcd_move_menu);
END_MENU();
}