Implement Dry-Run mode in G29
It just probe all the bed without appliying the matrix. Useful after a first G29 to check the topology.
This commit is contained in:
parent
80ae160c26
commit
55025558dc
@ -1168,6 +1168,7 @@ static void run_z_probe() {
|
||||
zPosition += home_retract_mm(Z_AXIS);
|
||||
plan_buffer_line(current_position[X_AXIS], current_position[Y_AXIS], zPosition, current_position[E_AXIS], feedrate/60, active_extruder);
|
||||
st_synchronize();
|
||||
endstops_hit_on_purpose();
|
||||
|
||||
// move back down slowly to find bed
|
||||
|
||||
@ -1185,6 +1186,7 @@ static void run_z_probe() {
|
||||
zPosition -= home_retract_mm(Z_AXIS) * 2;
|
||||
plan_buffer_line(current_position[X_AXIS], current_position[Y_AXIS], zPosition, current_position[E_AXIS], feedrate/60, active_extruder);
|
||||
st_synchronize();
|
||||
endstops_hit_on_purpose();
|
||||
|
||||
current_position[Z_AXIS] = st_get_position_mm(Z_AXIS);
|
||||
// make sure the planner knows where we are as it may be a bit different than we last said to move to
|
||||
@ -1389,11 +1391,11 @@ static float probe_pt(float x, float y, float z_before, ProbeAction retract_acti
|
||||
if (verbose_level > 2) {
|
||||
SERIAL_PROTOCOLPGM(MSG_BED);
|
||||
SERIAL_PROTOCOLPGM(" X: ");
|
||||
SERIAL_PROTOCOL(x + 0.0001);
|
||||
SERIAL_PROTOCOL_F(x, 3);
|
||||
SERIAL_PROTOCOLPGM(" Y: ");
|
||||
SERIAL_PROTOCOL(y + 0.0001);
|
||||
SERIAL_PROTOCOL_F(y, 3);
|
||||
SERIAL_PROTOCOLPGM(" Z: ");
|
||||
SERIAL_PROTOCOL(measured_z + 0.0001);
|
||||
SERIAL_PROTOCOL_F(measured_z, 3);
|
||||
SERIAL_EOL;
|
||||
}
|
||||
return measured_z;
|
||||
@ -2109,6 +2111,9 @@ inline void gcode_G28() {
|
||||
*
|
||||
* S Set the XY travel speed between probe points (in mm/min)
|
||||
*
|
||||
* D Dry-Run mode. Just evaluate the bed Topology - It does not apply or clean the rotation Matrix
|
||||
* Useful to check the topology after a first run of G29.
|
||||
*
|
||||
* V Set the verbose level (0-4). Example: "G29 V3"
|
||||
*
|
||||
* T Generate a Bed Topology Report. Example: "G29 P5 T" for a detailed report.
|
||||
@ -2150,6 +2155,7 @@ inline void gcode_G28() {
|
||||
}
|
||||
}
|
||||
|
||||
bool dryrun = code_seen('D') || code_seen('d');
|
||||
bool enhanced_g29 = code_seen('E') || code_seen('e');
|
||||
|
||||
#ifdef AUTO_BED_LEVELING_GRID
|
||||
@ -2159,7 +2165,10 @@ inline void gcode_G28() {
|
||||
#endif
|
||||
|
||||
if (verbose_level > 0)
|
||||
{
|
||||
SERIAL_PROTOCOLPGM("G29 Auto Bed Leveling\n");
|
||||
if (dryrun) SERIAL_ECHOLN("Running in DRY-RUN mode");
|
||||
}
|
||||
|
||||
int auto_bed_leveling_grid_points = AUTO_BED_LEVELING_GRID_POINTS;
|
||||
#ifndef DELTA
|
||||
@ -2216,22 +2225,27 @@ inline void gcode_G28() {
|
||||
|
||||
st_synchronize();
|
||||
|
||||
#ifdef DELTA
|
||||
reset_bed_level();
|
||||
#else
|
||||
if (!dryrun)
|
||||
{
|
||||
#ifdef DELTA
|
||||
reset_bed_level();
|
||||
#else
|
||||
|
||||
// make sure the bed_level_rotation_matrix is identity or the planner will get it incorectly
|
||||
//vector_3 corrected_position = plan_get_position_mm();
|
||||
//corrected_position.debug("position before G29");
|
||||
plan_bed_level_matrix.set_to_identity();
|
||||
vector_3 uncorrected_position = plan_get_position();
|
||||
//uncorrected_position.debug("position during G29");
|
||||
current_position[X_AXIS] = uncorrected_position.x;
|
||||
current_position[Y_AXIS] = uncorrected_position.y;
|
||||
current_position[Z_AXIS] = uncorrected_position.z;
|
||||
plan_set_position(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS], current_position[E_AXIS]);
|
||||
#endif
|
||||
// make sure the bed_level_rotation_matrix is identity or the planner will get it incorectly
|
||||
//vector_3 corrected_position = plan_get_position_mm();
|
||||
//corrected_position.debug("position before G29");
|
||||
plan_bed_level_matrix.set_to_identity();
|
||||
vector_3 uncorrected_position = plan_get_position();
|
||||
// uncorrected_position.debug("position during G29");
|
||||
|
||||
current_position[X_AXIS] = uncorrected_position.x;
|
||||
current_position[Y_AXIS] = uncorrected_position.y;
|
||||
current_position[Z_AXIS] = uncorrected_position.z;
|
||||
plan_set_position(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS], current_position[E_AXIS]);
|
||||
|
||||
#endif
|
||||
}
|
||||
|
||||
setup_for_endstop_move();
|
||||
|
||||
feedrate = homing_feedrate[Z_AXIS];
|
||||
@ -2381,12 +2395,12 @@ inline void gcode_G28() {
|
||||
} //do_topography_map
|
||||
|
||||
|
||||
set_bed_level_equation_lsq(plane_equation_coefficients);
|
||||
if (!dryrun) set_bed_level_equation_lsq(plane_equation_coefficients);
|
||||
free(plane_equation_coefficients);
|
||||
#else
|
||||
extrapolate_unprobed_bed_level();
|
||||
#else //Delta
|
||||
if (!dryrun) extrapolate_unprobed_bed_level();
|
||||
print_bed_level();
|
||||
#endif
|
||||
#endif //Delta
|
||||
|
||||
#else // !AUTO_BED_LEVELING_GRID
|
||||
|
||||
@ -2405,25 +2419,27 @@ inline void gcode_G28() {
|
||||
z_at_pt_3 = probe_pt(ABL_PROBE_PT_3_X, ABL_PROBE_PT_3_Y, current_position[Z_AXIS] + Z_RAISE_BETWEEN_PROBINGS, ProbeEngageAndRetract, verbose_level);
|
||||
}
|
||||
clean_up_after_endstop_move();
|
||||
set_bed_level_equation_3pts(z_at_pt_1, z_at_pt_2, z_at_pt_3);
|
||||
if (!dryrun) set_bed_level_equation_3pts(z_at_pt_1, z_at_pt_2, z_at_pt_3);
|
||||
|
||||
#endif // !AUTO_BED_LEVELING_GRID
|
||||
|
||||
#ifndef DELTA
|
||||
if (verbose_level > 0)
|
||||
plan_bed_level_matrix.debug(" \n\nBed Level Correction Matrix:");
|
||||
if (verbose_level > 0) plan_bed_level_matrix.debug(" \n\nBed Level Correction Matrix:");
|
||||
|
||||
// Correct the Z height difference from z-probe position and hotend tip position.
|
||||
// The Z height on homing is measured by Z-Probe, but the probe is quite far from the hotend.
|
||||
// When the bed is uneven, this height must be corrected.
|
||||
real_z = float(st_get_position(Z_AXIS)) / axis_steps_per_unit[Z_AXIS]; //get the real Z (since the auto bed leveling is already correcting the plane)
|
||||
x_tmp = current_position[X_AXIS] + X_PROBE_OFFSET_FROM_EXTRUDER;
|
||||
y_tmp = current_position[Y_AXIS] + Y_PROBE_OFFSET_FROM_EXTRUDER;
|
||||
z_tmp = current_position[Z_AXIS];
|
||||
if (!dryrun)
|
||||
{
|
||||
real_z = float(st_get_position(Z_AXIS)) / axis_steps_per_unit[Z_AXIS]; //get the real Z (since the auto bed leveling is already correcting the plane)
|
||||
x_tmp = current_position[X_AXIS] + X_PROBE_OFFSET_FROM_EXTRUDER;
|
||||
y_tmp = current_position[Y_AXIS] + Y_PROBE_OFFSET_FROM_EXTRUDER;
|
||||
z_tmp = current_position[Z_AXIS];
|
||||
|
||||
apply_rotation_xyz(plan_bed_level_matrix, x_tmp, y_tmp, z_tmp); //Apply the correction sending the probe offset
|
||||
current_position[Z_AXIS] = z_tmp - real_z + current_position[Z_AXIS]; //The difference is added to current position and sent to planner.
|
||||
plan_set_position(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS], current_position[E_AXIS]);
|
||||
apply_rotation_xyz(plan_bed_level_matrix, x_tmp, y_tmp, z_tmp); //Apply the correction sending the probe offset
|
||||
current_position[Z_AXIS] = z_tmp - real_z + current_position[Z_AXIS]; //The difference is added to current position and sent to planner.
|
||||
plan_set_position(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS], current_position[E_AXIS]);
|
||||
}
|
||||
#endif
|
||||
|
||||
#ifdef Z_PROBE_SLED
|
||||
|