1
0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2024-11-27 13:56:24 +00:00

Extend Heater Overshoot Options (#21273)

Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
This commit is contained in:
Keith Bennett 2021-03-06 20:55:37 -08:00 committed by GitHub
parent ced1bb9404
commit 5dc8f5cfab
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

View File

@ -476,6 +476,15 @@
#define BED_MAXTEMP 150 #define BED_MAXTEMP 150
#define CHAMBER_MAXTEMP 60 #define CHAMBER_MAXTEMP 60
/**
* Thermal Overshoot
* During heatup (and printing) the temperature can often "overshoot" the target by many degrees
* (especially before PID tuning). Setting the target temperature too close to MAXTEMP guarantees
* a MAXTEMP shutdown! Use these values to forbid temperatures being set too close to MAXTEMP.
*/
#define HOTEND_OVERSHOOT 15 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
#define BED_OVERSHOOT 10 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
//=========================================================================== //===========================================================================
//============================= PID Settings ================================ //============================= PID Settings ================================
//=========================================================================== //===========================================================================