0
0
Fork 0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2025-01-30 21:58:06 +00:00

[1.1.x] G33 MIN_STEPS_PER_SEGMENT (#10385)

This commit is contained in:
Luc Van Daele 2018-04-13 03:19:42 +02:00 committed by Scott Lahteine
parent db81a1d4a2
commit 6e30d1bef1
11 changed files with 12 additions and 10 deletions

View file

@ -3095,7 +3095,7 @@ static void homeaxis(const AxisEnum axis) {
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("delta_endstop_adj:");
#endif
do_homing_move(axis, delta_endstop_adj[axis] - MIN_STEPS_PER_SEGMENT / planner.axis_steps_per_mm[axis] * Z_HOME_DIR);
do_homing_move(axis, delta_endstop_adj[axis] - (MIN_STEPS_PER_SEGMENT + 1) * planner.steps_to_mm[axis] * Z_HOME_DIR);
}
#else

View file

@ -181,6 +181,8 @@
#error "MANUAL_PROBE_Z_RANGE is now LCD_PROBE_Z_RANGE. Please update your configuration."
#elif !defined(MIN_STEPS_PER_SEGMENT)
#error Please replace "const int dropsegments" with "#define MIN_STEPS_PER_SEGMENT" (and increase by 1) in Configuration_adv.h.
#elif MIN_STEPS_PER_SEGMENT <= 0
#error "MIN_STEPS_PER_SEGMENT needs to be at least 1"
#elif defined(PREVENT_DANGEROUS_EXTRUDE)
#error "PREVENT_DANGEROUS_EXTRUDE is now PREVENT_COLD_EXTRUSION. Please update your configuration."
#elif defined(SCARA)

View file

@ -529,7 +529,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 73.5 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -529,7 +529,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 63 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -529,7 +529,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 73.5 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -534,7 +534,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 121.5 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -519,7 +519,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 121.5 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -519,7 +519,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 78.0 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -505,7 +505,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 110.0 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -523,7 +523,7 @@
// Set the radius for the calibration probe points - max DELTA_PRINTABLE_RADIUS for non-eccentric probes
#define DELTA_CALIBRATION_RADIUS 121.5 // mm
// Set the steprate for papertest probing
#define PROBE_MANUALLY_STEP (MIN_STEPS_PER_SEGMENT / DEFAULT_XYZ_STEPS_PER_UNIT)
#define PROBE_MANUALLY_STEP 0.05 // mm
#endif
// Print surface diameter/2 minus unreachable space (avoid collisions with vertical towers).

View file

@ -2715,7 +2715,7 @@ void kill_screen(const char* lcd_msg) {
do_blocking_move_to_xy(rx, ry);
lcd_synchronize();
move_menu_scale = PROBE_MANUALLY_STEP;
move_menu_scale = max(PROBE_MANUALLY_STEP, MIN_STEPS_PER_SEGMENT / float(DEFAULT_XYZ_STEPS_PER_UNIT));
lcd_goto_screen(lcd_move_z);
}