mirror of
https://github.com/MarlinFirmware/Marlin.git
synced 2024-11-27 05:48:43 +00:00
Preheat before Power Loss Recovery homing (#20697)
This commit is contained in:
parent
abea8ff8f4
commit
8edcf03715
@ -342,6 +342,30 @@ void PrintJobRecovery::resume() {
|
||||
gcode.process_subcommands_now_P(PSTR("M420 S0 Z0"));
|
||||
#endif
|
||||
|
||||
#if HAS_HEATED_BED
|
||||
const int16_t bt = info.target_temperature_bed;
|
||||
if (bt) {
|
||||
// Restore the bed temperature
|
||||
sprintf_P(cmd, PSTR("M190 S%i"), bt);
|
||||
gcode.process_subcommands_now(cmd);
|
||||
}
|
||||
#endif
|
||||
|
||||
// Restore all hotend temperatures
|
||||
#if HAS_HOTEND
|
||||
HOTEND_LOOP() {
|
||||
const int16_t et = info.target_temperature[e];
|
||||
if (et) {
|
||||
#if HAS_MULTI_HOTEND
|
||||
sprintf_P(cmd, PSTR("T%i S"), e);
|
||||
gcode.process_subcommands_now(cmd);
|
||||
#endif
|
||||
sprintf_P(cmd, PSTR("M109 S%i"), et);
|
||||
gcode.process_subcommands_now(cmd);
|
||||
}
|
||||
}
|
||||
#endif
|
||||
|
||||
// Reset E, raise Z, home XY...
|
||||
#if Z_HOME_DIR > 0
|
||||
|
||||
@ -353,20 +377,11 @@ void PrintJobRecovery::resume() {
|
||||
|
||||
#else // "G92.9 E0 ..."
|
||||
|
||||
// Set Z to 0, raise Z by info.zraise, and Home (XY only for Cartesian)
|
||||
// with no raise. (Only do simulated homing in Marlin Dev Mode.)
|
||||
|
||||
sprintf_P(cmd, PSTR("G92.9 E0 "
|
||||
#if ENABLED(BACKUP_POWER_SUPPLY)
|
||||
"Z%s" // Z was already raised at outage
|
||||
#else
|
||||
"Z0\nG1Z%s" // Set Z=0 and Raise Z now
|
||||
#endif
|
||||
),
|
||||
dtostrf(info.zraise, 1, 3, str_1)
|
||||
);
|
||||
// If a Z raise occurred at outage restore Z, otherwise raise Z now
|
||||
sprintf_P(cmd, PSTR("G92.9 E0 " TERN(BACKUP_POWER_SUPPLY, "Z%s", "Z0\nG1Z%s")), dtostrf(info.zraise, 1, 3, str_1));
|
||||
gcode.process_subcommands_now(cmd);
|
||||
|
||||
// Home safely with no Z raise
|
||||
gcode.process_subcommands_now_P(PSTR(
|
||||
"G28R0" // No raise during G28
|
||||
#if IS_CARTESIAN && DISABLED(POWER_LOSS_RECOVER_ZHOME)
|
||||
@ -404,30 +419,6 @@ void PrintJobRecovery::resume() {
|
||||
#endif
|
||||
#endif
|
||||
|
||||
#if HAS_HEATED_BED
|
||||
const int16_t bt = info.target_temperature_bed;
|
||||
if (bt) {
|
||||
// Restore the bed temperature
|
||||
sprintf_P(cmd, PSTR("M190 S%i"), bt);
|
||||
gcode.process_subcommands_now(cmd);
|
||||
}
|
||||
#endif
|
||||
|
||||
// Restore all hotend temperatures
|
||||
#if HAS_HOTEND
|
||||
HOTEND_LOOP() {
|
||||
const int16_t et = info.target_temperature[e];
|
||||
if (et) {
|
||||
#if HAS_MULTI_HOTEND
|
||||
sprintf_P(cmd, PSTR("T%i S"), e);
|
||||
gcode.process_subcommands_now(cmd);
|
||||
#endif
|
||||
sprintf_P(cmd, PSTR("M109 S%i"), et);
|
||||
gcode.process_subcommands_now(cmd);
|
||||
}
|
||||
}
|
||||
#endif
|
||||
|
||||
// Select the previously active tool (with no_move)
|
||||
#if HAS_MULTI_EXTRUDER
|
||||
sprintf_P(cmd, PSTR("T%i S"), info.active_extruder);
|
||||
|
Loading…
Reference in New Issue
Block a user