mirror of
https://github.com/MarlinFirmware/Marlin.git
synced 2024-11-22 18:25:18 +00:00
Clean up some temp config
This commit is contained in:
parent
785a7028bf
commit
98b55421a5
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 5 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 5 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 5 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 5 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 250
|
||||
#define HEATER_1_MAXTEMP 250
|
||||
#define HEATER_2_MAXTEMP 250
|
||||
#define HEATER_3_MAXTEMP 250
|
||||
#define HEATER_4_MAXTEMP 250
|
||||
#define HEATER_5_MAXTEMP 250
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define BED_MAXTEMP 130
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define BED_MAXTEMP 130
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -389,37 +389,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 6 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 6 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 6 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 6 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define BED_MAXTEMP 130
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 285
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 115
|
||||
#define BED_MAXTEMP 115
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 115
|
||||
#define BED_MAXTEMP 115
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 260
|
||||
#define HEATER_1_MAXTEMP 260
|
||||
#define HEATER_2_MAXTEMP 260
|
||||
#define HEATER_3_MAXTEMP 260
|
||||
#define HEATER_4_MAXTEMP 260
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -396,30 +396,27 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 230
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 260
|
||||
#define HEATER_1_MAXTEMP 260
|
||||
#define HEATER_2_MAXTEMP 260
|
||||
#define HEATER_3_MAXTEMP 260
|
||||
#define HEATER_4_MAXTEMP 260
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -389,37 +389,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 4 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 4 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 415
|
||||
#define HEATER_1_MAXTEMP 415
|
||||
#define HEATER_2_MAXTEMP 415
|
||||
#define HEATER_3_MAXTEMP 415
|
||||
#define HEATER_4_MAXTEMP 415
|
||||
#define HEATER_5_MAXTEMP 415
|
||||
#define BED_MAXTEMP 165
|
||||
#define BED_MAXTEMP 165
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 250
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 265
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -397,37 +397,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 75
|
||||
#define BED_MAXTEMP 75
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define BED_MAXTEMP 125
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -390,37 +390,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 15 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 15 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 15 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 15 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 245
|
||||
#define HEATER_1_MAXTEMP 245
|
||||
#define HEATER_2_MAXTEMP 245
|
||||
#define HEATER_3_MAXTEMP 245
|
||||
#define HEATER_4_MAXTEMP 245
|
||||
#define HEATER_5_MAXTEMP 245
|
||||
#define BED_MAXTEMP 115
|
||||
#define BED_MAXTEMP 115
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -433,38 +433,35 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 290
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#if ENABLED(BED_AC)
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
#else
|
||||
#define BED_MAXTEMP 100
|
||||
#define BED_MAXTEMP 100
|
||||
#endif
|
||||
|
||||
//===========================================================================
|
||||
|
@ -403,37 +403,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 410
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -397,37 +397,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 410
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define BED_MAXTEMP 125
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define BED_MAXTEMP 125
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define BED_MAXTEMP 125
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -393,37 +393,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 265
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -408,37 +408,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -396,37 +396,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 250
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 100
|
||||
#define BED_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -389,37 +389,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -389,37 +389,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 250
|
||||
#define HEATER_1_MAXTEMP 250
|
||||
#define HEATER_2_MAXTEMP 250
|
||||
#define HEATER_3_MAXTEMP 250
|
||||
#define HEATER_4_MAXTEMP 250
|
||||
#define HEATER_5_MAXTEMP 250
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -391,37 +391,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
//#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -419,37 +419,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 3 // (seconds)
|
||||
#define TEMP_HYSTERESIS 2 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 3 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_HYSTERESIS 2 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -389,37 +389,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -415,37 +415,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 250
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 100
|
||||
#define BED_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 260
|
||||
#define HEATER_1_MAXTEMP 260
|
||||
#define HEATER_2_MAXTEMP 260
|
||||
#define HEATER_3_MAXTEMP 260
|
||||
#define HEATER_4_MAXTEMP 260
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define BED_MAXTEMP 130
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -390,30 +390,27 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
// Tronxy X5S-2E:
|
||||
// WARNING: Never exceed 260C. The OEM stock model uses low temperature heat breaks with PTFE-lining.
|
||||
#define HEATER_0_MAXTEMP 260
|
||||
@ -424,7 +421,7 @@
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
// Tronxy X5S-2E:
|
||||
// The OEM stock model uses a clone MK3a 300 @ 12V with no insulation and can reach a maximum 70C at 25C ambient.
|
||||
#define BED_MAXTEMP 81
|
||||
#define BED_MAXTEMP 81
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -408,37 +408,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 2 // (seconds)
|
||||
#define TEMP_HYSTERESIS 5 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 2 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 5 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 2 // (seconds)
|
||||
#define TEMP_HYSTERESIS 5 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 2 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_HYSTERESIS 5 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -407,37 +407,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 5 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 5 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 230
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 260
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -409,37 +409,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define BED_MAXTEMP 120
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 250
|
||||
#define HEATER_1_MAXTEMP 250
|
||||
#define HEATER_2_MAXTEMP 250
|
||||
#define HEATER_3_MAXTEMP 250
|
||||
#define HEATER_4_MAXTEMP 250
|
||||
#define HEATER_5_MAXTEMP 250
|
||||
#define BED_MAXTEMP 115
|
||||
#define BED_MAXTEMP 115
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 250
|
||||
#define HEATER_1_MAXTEMP 250
|
||||
#define HEATER_2_MAXTEMP 250
|
||||
#define HEATER_3_MAXTEMP 250
|
||||
#define HEATER_4_MAXTEMP 250
|
||||
#define HEATER_5_MAXTEMP 250
|
||||
#define BED_MAXTEMP 115
|
||||
#define BED_MAXTEMP 115
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -393,37 +393,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 1 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -392,37 +392,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -396,37 +396,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 16 // (seconds)
|
||||
#define TEMP_HYSTERESIS 12 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 5 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 16 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 5 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 12 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 245
|
||||
#define HEATER_1_MAXTEMP 245
|
||||
#define HEATER_2_MAXTEMP 245
|
||||
#define HEATER_3_MAXTEMP 245
|
||||
#define HEATER_4_MAXTEMP 245
|
||||
#define HEATER_5_MAXTEMP 245
|
||||
#define BED_MAXTEMP 115
|
||||
#define BED_MAXTEMP 115
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -389,37 +389,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 0 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -388,37 +388,34 @@
|
||||
//#define TEMP_SENSOR_1_AS_REDUNDANT
|
||||
#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
|
||||
|
||||
// Extruder temperature must be close to target for this long before M109 returns success
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
#define TEMP_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Bed temperature must be close to target for this long before M190 returns success
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds)
|
||||
#define TEMP_BED_HYSTERESIS 3 // (degC) range of +/- temperatures considered "close" to the target one
|
||||
#define TEMP_BED_WINDOW 1 // (degC) Window around target to start the residency timer x degC early.
|
||||
#define TEMP_BED_RESIDENCY_TIME 10 // (seconds) Time to wait for bed to "settle" in M190
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// The minimal temperature defines the temperature below which the heater will not be enabled It is used
|
||||
// to check that the wiring to the thermistor is not broken.
|
||||
// Otherwise this would lead to the heater being powered on all the time.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
#define HEATER_1_MINTEMP 5
|
||||
#define HEATER_2_MINTEMP 5
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
|
||||
// When temperature exceeds max temp, your heater will be switched off.
|
||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||
// You should use MINTEMP for thermistor short/failure protection.
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
// (Use MINTEMP for thermistor short/failure protection.)
|
||||
#define HEATER_0_MAXTEMP 275
|
||||
#define HEATER_1_MAXTEMP 275
|
||||
#define HEATER_2_MAXTEMP 275
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
Loading…
Reference in New Issue
Block a user