🐛 Fix M140 print job timer autostart (#22046)
This commit is contained in:
parent
04bea72787
commit
aeb8097cbc
@ -1824,11 +1824,20 @@
|
|||||||
/**
|
/**
|
||||||
* Print Job Timer
|
* Print Job Timer
|
||||||
*
|
*
|
||||||
* Automatically start and stop the print job timer on M104/M109/M190.
|
* Automatically start and stop the print job timer on M104/M109/M140/M190/M141/M191.
|
||||||
|
* The print job timer will only be stopped if the bed/chamber target temp is
|
||||||
|
* below BED_MINTEMP/CHAMBER_MINTEMP.
|
||||||
*
|
*
|
||||||
* M104 (hotend, no wait) - high temp = none, low temp = stop timer
|
* M104 (hotend, no wait) - high temp = none, low temp = stop timer
|
||||||
* M109 (hotend, wait) - high temp = start timer, low temp = stop timer
|
* M109 (hotend, wait) - high temp = start timer, low temp = stop timer
|
||||||
* M190 (bed, wait) - high temp = start timer, low temp = none
|
* M140 (bed, no wait) - high temp = none, low temp = stop timer
|
||||||
|
* M190 (bed, wait) - high temp = start timer, low temp = none
|
||||||
|
* M141 (chamber, no wait) - high temp = none, low temp = stop timer
|
||||||
|
* M191 (chamber, wait) - high temp = start timer, low temp = none
|
||||||
|
*
|
||||||
|
* For M104/M109, high temp is anything over EXTRUDE_MINTEMP / 2.
|
||||||
|
* For M140/M190, high temp is anything over BED_MINTEMP.
|
||||||
|
* For M141/M191, high temp is anything over CHAMBER_MINTEMP.
|
||||||
*
|
*
|
||||||
* The timer can also be controlled with the following commands:
|
* The timer can also be controlled with the following commands:
|
||||||
*
|
*
|
||||||
|