mirror of
https://github.com/MarlinFirmware/Marlin.git
synced 2024-11-27 22:08:02 +00:00
Have position_is_reachable_by_probe use the whole bed (#10019)
Previously `position_is_reachable_by_probe` was limited to the area specified for `G29` mesh leveling (even if leveling was disabled). This change will properly consider the entire bed area so that `G30` and other non-leveling probing may take place.
This commit is contained in:
parent
9508f9ec75
commit
fa12866de3
@ -536,9 +536,10 @@ void do_blocking_move_to_xy(const float &x, const float &y, const float &fr_mm_s
|
||||
}
|
||||
|
||||
inline bool position_is_reachable_by_probe(const float &rx, const float &ry) {
|
||||
// Add 0.001 margin to deal with float imprecision
|
||||
return WITHIN(rx, MIN_PROBE_X - 0.001, MAX_PROBE_X + 0.001)
|
||||
&& WITHIN(ry, MIN_PROBE_Y - 0.001, MAX_PROBE_Y + 0.001);
|
||||
const float nx = rx - (X_PROBE_OFFSET_FROM_EXTRUDER), ny = ry - (Y_PROBE_OFFSET_FROM_EXTRUDER);
|
||||
return position_is_reachable(rx, ry)
|
||||
&& WITHIN(nx, X_MIN_BED - 0.001, X_MAX_BED + 0.001)
|
||||
&& WITHIN(ny, Y_MIN_BED - 0.001, Y_MAX_BED + 0.001);
|
||||
}
|
||||
|
||||
#endif // CARTESIAN
|
||||
|