1
0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2024-11-30 15:26:18 +00:00
Commit Graph

425 Commits

Author SHA1 Message Date
Thomas Moore
ab4549d2bc [2.0.x] Add simultaneous retraction for mixing extruder (#11941) 2018-10-01 23:32:02 -05:00
dot-bob
b0fd8f2d74 Add option to move Z on double-click when idle 2018-10-01 01:41:11 -05:00
Scott Lahteine
e78bdd654d Clean up BABYSTEP options 2018-10-01 01:29:21 -05:00
Scott Lahteine
3c40933713 Remove trailing spaces, old comment 2018-09-30 20:47:06 -05:00
Thomas Moore
3286325044 Add TMC2130 sensorless probing 2018-09-29 18:54:14 -05:00
Victor Tseng
93839e2f73 Add option to enable/disable autoretract altogether (#11904) 2018-09-28 16:52:56 -05:00
Scott Lahteine
241168926d Update some configs 2018-09-27 16:42:59 -05:00
Scott Lahteine
cee34f7290
Followup for BABYSTEP_HOTEND_Z_OFFSET (#11916) 2018-09-24 21:46:56 -04:00
teemuatlut
884ad75cb8 Update config files 2018-09-24 17:26:18 -04:00
InsanityAutomation
1104054d73 2.0 IDEX Independent z offset and other fixes (#11862)
* Add Formbot Raptor board

Co-Authored-By: InsanityAutomation <insanityautomation@users.noreply.github.com>

* Add a second Z probe Z offset

Co-Authored-By: InsanityAutomation <insanityautomation@users.noreply.github.com>

* Modify method to utilize live adjustment of hotend z offset

Should probably move config option to babystepping and rename as it may now apply to all multiextruder systems

* Move config item and catchup other code to current method
2018-09-24 09:40:48 -05:00
Scott Lahteine
ddcbf80f23 Followup for Z_TRIPLE_ENDSTOPS 2018-09-23 12:22:31 -04:00
Roxy-3D
d3d6be8210 Add MAX7219 reverse units option (#11860) 2018-09-19 18:54:51 -05:00
InsanityAutomation
f38570ac55 Add custom user menu title (#11769) 2018-09-19 15:04:34 -05:00
Scott Lahteine
f5c210d33d Config changes supporting up to 6 extruders 2018-09-16 22:22:35 -05:00
Holger Müller
1a6f2b29b8 Add support for Triple-Z steppers/endstops 2018-09-16 00:35:58 -05:00
Scott Lahteine
f79a5a9dee Tweak spacing of L6470 options 2018-09-12 23:18:11 -05:00
Sam Lane
1b6bc19427 Add external closed loop controller support 2018-09-10 03:17:17 -05:00
Marcio Teixeira
beb51c2d58 Show manual extrusion moves as relative in LCD
- Implements FR#11724
- Old behavior can be restored by commenting out MANUAL_E_MOVES_RELATIVE
2018-09-06 02:00:25 -05:00
Scott Lahteine
e3fc9aa35f Update some config comments 2018-08-31 16:03:44 -05:00
Michael Triffon
f8c52c9c29 Azteeg X5 Mini WiFi support (#11601) 2018-08-21 23:58:26 -05:00
Scott Lahteine
2d3317a35b Prettify Dual X Carriage description 2018-08-21 23:34:29 -05:00
Greg Nutt
a1a5367380 Smoothieboard V1.0/1.1 and A5984 support 2018-08-09 23:03:17 -05:00
Scott Lahteine
9c62c47579
[2.0.x] Fix Dual X Carriage tool change crash (#11447) 2018-08-03 20:47:29 -05:00
teemuatlut
fbcdf5eaeb Simplify stepper driver per-axis selection 2018-07-25 02:47:43 -05:00
Roxy-3D
9660996cc3
Add Multi Unit Support for Max7219 to bugfix_2.0.0 (#11285)
* Add Multi Unit Support for Max7219 to bugfix_2.0.0

* Apply multi-MAX7219 to example configs

* Tweak some spacing, macros
2018-07-19 13:56:47 -05:00
Scott Lahteine
665ac1e4d0 Add POWER_LOSS_PIN support 2018-07-18 19:55:10 -05:00
Scott Lahteine
e0ab8acf19 Add "Marlin Dev Mode" option 2018-07-02 22:55:21 -05:00
Scott Lahteine
bd7f5848f1
Remove JUNCTION_DEVIATION_INCLUDE_E option (#11147) 2018-06-29 22:42:05 -05:00
etagle
5b49fccf80 Add stepper driver DIR delay configuration option
...and recommended pulse width configuration for A4988
2018-06-26 13:28:04 -05:00
Scott Lahteine
d4795e5b8e
[2.0.x] Tweaks and additions for MAX7219 (#11034) 2018-06-18 22:04:03 -05:00
Simon Jouet
e2aeda61ed HAL for Espressif ESP32 Wifi 2018-06-13 19:33:35 -05:00
etagle
6f14bcaa3e Add MAXIMUM_STEPPER_RATE, enforce in multi-stepping
The timing value should be properly set for ALL boards. The compiler will check and set maximum step rate calculations based on those values.
2018-06-10 16:02:47 -05:00
etagle
39a7e7720d Adaptive multiaxis step smoothing
- Stepper bugs fixed
- Support MIXING_EXTRUDER with Linear Advance
- Miscellaneous cleanup
2018-06-10 16:02:47 -05:00
Scott Lahteine
8a376e6beb Update MINIMUM_STEPPER_PULSE description 2018-06-10 00:13:03 -05:00
Scott Lahteine
2deff0d9b9 Fix/Improve junction deviation
- Respect axis max acceleration limits instead of forcing a fixed acceleration value.
- The `junction_unit_vec` ensures proper handling of entry and exit speeds even when the axes involved have different limits.
2018-05-31 20:09:53 -05:00
Scott Lahteine
2e139fe50f Tweak configuration spacing 2018-05-26 18:33:51 -05:00
Scott Lahteine
931ab4ec40 Rename Junction Deviation options 2018-05-26 18:33:51 -05:00
Jiri Jaburek
43ddb29f9e Add FAN_MAX_PWM for M106-controlled fans 2018-05-15 21:18:46 -05:00
Scott Lahteine
acacee80a2 Add JUNCTION_ACCELERATION_FACTOR to configs
Part of #10688

Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-05-11 23:13:27 -05:00
Scott Lahteine
4d4bf7897d Junction Deviation jerk limiting option 2018-05-08 10:08:54 -05:00
Scott Lahteine
840ff60952 Bring some configs up to date 2018-05-06 02:42:27 -05:00
nightdemonx
e911635fb1 Add thermocouple with AD8495 support 2018-05-02 08:43:16 -05:00
Scott Lahteine
05c33833e7
[2.0.x] Add NO_LCD_MENUS option (#10582) 2018-04-30 21:16:31 -05:00
Scott Lahteine
11ab017dd0 Creality3D Power-Loss Recovery 2018-04-21 21:56:50 -05:00
Marcio Teixeira
5cc7916e69 Add G29_RETRY_AND_RECOVER feature
- Add an option to retry G29, optionally executing a G-code procedure after each failed probe.
2018-04-19 19:45:53 -05:00
Sean
2d9b0a66fe Add Filament Change accelerations 2018-04-09 23:57:27 -05:00
Lenbok
0e8242180d Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:06 -05:00
Sean
2fa0a73c2c Implement filament change continuous purge 2018-04-04 20:57:51 -05:00
Scott Lahteine
1d22609473 MIN_PROBE_EDGE replaces DELTA_PROBEABLE_RADIUS 2018-03-19 04:11:46 -05:00
Marcio Teixeira
c24dbcbfe1 When STATUS_EXPIRE_SECONDS is 0, hide the position. (#10081)
Some users may prefer to hide the position updates on the `LIGHTWEIGHT_UI` altogether. This leads to an even less cluttered display (it also saves on SPI traffic and one byte of RAM).
2018-03-14 02:44:30 -05:00