Scott Lahteine
e978e6e782
[2.0.x] Arrange LCD options by type ( #10630 )
2018-05-06 19:16:55 -05:00
Scott Lahteine
840ff60952
Bring some configs up to date
2018-05-06 02:42:27 -05:00
nightdemonx
e911635fb1
Add thermocouple with AD8495 support
2018-05-02 08:43:16 -05:00
Scott Lahteine
b7e938a9fb
LCD_BED_LEVELING enables a sub-menu for ABL
2018-05-01 07:13:56 -05:00
Scott Lahteine
c87b0e21be
Add units to probe speed comments
2018-04-30 23:50:28 -05:00
Scott Lahteine
05c33833e7
[2.0.x] Add NO_LCD_MENUS option ( #10582 )
2018-04-30 21:16:31 -05:00
Scott Lahteine
ed8d2bc225
Clean up some endstop inverting examples
2018-04-28 08:04:43 -05:00
Scott Lahteine
9e07df5c1b
Extra options for LEVEL_BED_CORNERS ( #10483 )
2018-04-22 02:50:48 -05:00
Scott Lahteine
a90cbc6339
[2.0.x] Wait for bed heaters between probing ( #10472 )
2018-04-21 15:43:21 -05:00
KangDroid
6c535081ec
[2.0.x] Add optional menu item to toggle software endstops ( #10389 )
2018-04-13 00:24:09 -05:00
Yunhui Fu
c96412a78f
[2.0.x] UTF-8 language translation support ( #10213 )
2018-04-12 20:14:01 -05:00
Scott Lahteine
82dafbba33
Add Z_PROBE_LOW_POINT to example configs
2018-04-09 01:55:05 -05:00
Scott Lahteine
dca69efc11
Update Bed PID comments
2018-04-08 06:44:47 -05:00
Scott Lahteine
5932df7ea1
Add BEZIER_JERK_CONTROL to example configs
2018-04-07 21:03:22 -05:00
Scott Lahteine
5b3bda1c16
Add Chamber Temp options to example configs
2018-04-06 23:09:06 -05:00
Scott Lahteine
adcb87f0db
Z Endstop Servo => Z Probe Servo
2018-04-01 23:54:21 -05:00
Scott Lahteine
dd2949922b
Consolidate 3-point leveling point options
2018-03-19 04:12:20 -05:00
Scott Lahteine
c6ff39cc14
Spacing cleanup
2018-03-17 16:49:08 -05:00
Scott Lahteine
14c03cb6f4
[2.0.x] Make MIN_PROBE_EDGE a general option (for electronic probes) ( #10069 )
...
Some probes don't work near the edges of the bed. This change promotes MIN_PROBE_EDGE to a general setting that applies to all probing functions.
2018-03-13 01:15:22 -05:00
Scott Lahteine
28f1276286
[2.0.x] Add Z_AFTER_PROBING option ( #10058 )
...
Some "fix-mounted" probes need manual stowing. And after probing some may prefer to raise or lower the nozzle. This restores an old option but tailors it to allow raise or lower as preferred.
2018-03-11 13:07:55 -05:00
Scott Lahteine
79e6d890d5
Add UNKNOWN_Z_NO_RAISE to example configs
2018-03-10 00:17:34 -06:00
Scott Lahteine
a2a672449a
Updated boot screen description
2018-03-03 20:04:17 -06:00
Scott Lahteine
4953fb1c88
Standardize encoder defaults
2018-02-24 22:34:45 -06:00
Scott Lahteine
5684beae90
Bring some configs up to speed
2018-02-24 21:56:27 -06:00
Scott Lahteine
2024775e07
Spanish (UTF8) Language ( #9786 )
...
From #7314 by @MrAmericanMike
2018-02-23 20:24:02 -06:00
Scott Lahteine
17d984eab3
Add RESTORE_LEVELING_AFTER_G28 to example configs
2018-02-23 13:38:54 -06:00
Scott Lahteine
7d8c6b3f3c
Add 20x4 option for Sainsmart LCD ( #9740 )
2018-02-21 00:46:25 -06:00
Scott Lahteine
8733d5a296
Add NUM_RUNOUT_SENSORS to example configs
2018-02-19 07:02:50 -06:00
Scott Lahteine
ca55f2927a
Pulldown pin mode support ( #9701 )
...
Implemented for LPC1768.
2018-02-18 19:26:23 -06:00
Roxy-3D
21e60fd3ed
Allow user to control Z-Height correction for off mesh movements ( #9661 )
2018-02-15 15:07:42 -06:00
Scott Lahteine
2ec65051fd
Fix serial comment sp.
2018-02-13 22:40:56 -06:00
Scott Lahteine
38c7d53bf7
Repair some spacing
2018-02-10 19:33:26 -06:00
Scott Lahteine
4aff6c1c32
Tronxy X5S pins and configuration
2018-02-10 15:07:04 -06:00