1
0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2024-11-27 22:08:02 +00:00
Commit Graph

32 Commits

Author SHA1 Message Date
Scott Lahteine
aaaf09bda2 BEZIER_JERK_CONTROL => S_CURVE_ACCELERATION 2018-05-26 18:33:51 -05:00
Scott Lahteine
4b2f6e3b2b
[2.0.x] Add endstop noise filter (#10796) 2018-05-21 15:51:38 -05:00
Scott Lahteine
b7dfc79988
Disable SERIAL_PORT_2 by default and sanity-check it (#10748) 2018-05-14 21:38:24 -05:00
Scott Lahteine
e978e6e782
[2.0.x] Arrange LCD options by type (#10630) 2018-05-06 19:16:55 -05:00
nightdemonx
e911635fb1 Add thermocouple with AD8495 support 2018-05-02 08:43:16 -05:00
Scott Lahteine
b7e938a9fb LCD_BED_LEVELING enables a sub-menu for ABL 2018-05-01 07:13:56 -05:00
Scott Lahteine
c87b0e21be Add units to probe speed comments 2018-04-30 23:50:28 -05:00
Scott Lahteine
05c33833e7
[2.0.x] Add NO_LCD_MENUS option (#10582) 2018-04-30 21:16:31 -05:00
Scott Lahteine
ed8d2bc225 Clean up some endstop inverting examples 2018-04-28 08:04:43 -05:00
Scott Lahteine
9e07df5c1b
Extra options for LEVEL_BED_CORNERS (#10483) 2018-04-22 02:50:48 -05:00
Scott Lahteine
a90cbc6339
[2.0.x] Wait for bed heaters between probing (#10472) 2018-04-21 15:43:21 -05:00
KangDroid
6c535081ec [2.0.x] Add optional menu item to toggle software endstops (#10389) 2018-04-13 00:24:09 -05:00
Yunhui Fu
c96412a78f [2.0.x] UTF-8 language translation support (#10213) 2018-04-12 20:14:01 -05:00
Scott Lahteine
82dafbba33 Add Z_PROBE_LOW_POINT to example configs 2018-04-09 01:55:05 -05:00
Scott Lahteine
dca69efc11 Update Bed PID comments 2018-04-08 06:44:47 -05:00
Scott Lahteine
5932df7ea1 Add BEZIER_JERK_CONTROL to example configs 2018-04-07 21:03:22 -05:00
Scott Lahteine
5b3bda1c16 Add Chamber Temp options to example configs 2018-04-06 23:09:06 -05:00
Scott Lahteine
adcb87f0db Z Endstop Servo => Z Probe Servo 2018-04-01 23:54:21 -05:00
Scott Lahteine
dd2949922b Consolidate 3-point leveling point options 2018-03-19 04:12:20 -05:00
Scott Lahteine
c6ff39cc14 Spacing cleanup 2018-03-17 16:49:08 -05:00
Scott Lahteine
14c03cb6f4
[2.0.x] Make MIN_PROBE_EDGE a general option (for electronic probes) (#10069)
Some probes don't work near the edges of the bed. This change promotes MIN_PROBE_EDGE to a general setting that applies to all probing functions.
2018-03-13 01:15:22 -05:00
Scott Lahteine
28f1276286
[2.0.x] Add Z_AFTER_PROBING option (#10058)
Some "fix-mounted" probes need manual stowing. And after probing some may prefer to raise or lower the nozzle. This restores an old option but tailors it to allow raise or lower as preferred.
2018-03-11 13:07:55 -05:00
Scott Lahteine
79e6d890d5 Add UNKNOWN_Z_NO_RAISE to example configs 2018-03-10 00:17:34 -06:00
Scott Lahteine
a2a672449a Updated boot screen description 2018-03-03 20:04:17 -06:00
Scott Lahteine
4953fb1c88 Standardize encoder defaults 2018-02-24 22:34:45 -06:00
Scott Lahteine
5684beae90 Bring some configs up to speed 2018-02-24 21:56:27 -06:00
Scott Lahteine
2024775e07
Spanish (UTF8) Language (#9786)
From #7314 by @MrAmericanMike
2018-02-23 20:24:02 -06:00
Scott Lahteine
17d984eab3 Add RESTORE_LEVELING_AFTER_G28 to example configs 2018-02-23 13:38:54 -06:00
Scott Lahteine
7d8c6b3f3c
Add 20x4 option for Sainsmart LCD (#9740) 2018-02-21 00:46:25 -06:00
Scott Lahteine
8733d5a296 Add NUM_RUNOUT_SENSORS to example configs 2018-02-19 07:02:50 -06:00
Scott Lahteine
ca55f2927a
Pulldown pin mode support (#9701)
Implemented for LPC1768.
2018-02-18 19:26:23 -06:00
Scott Lahteine
7d093edc18 Add Tronxy XY100 configuration
Based on #9674
2018-02-17 15:48:32 -06:00