1
0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2024-11-29 23:07:42 +00:00
Commit Graph

833 Commits

Author SHA1 Message Date
Scott Lahteine
b7ddfddf51 Add MAXIMUM_STEPPER_RATE, enforce in multi-stepping
The timing value should be properly set for ALL boards. The compiler will check and set maximum step rate calculations based on those values.

Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-06-10 01:56:00 -05:00
Scott Lahteine
949ee7afe9 BEZIER_JERK_CONTROL => S_CURVE_ACCELERATION 2018-05-26 18:31:57 -05:00
Scott Lahteine
a971cacb06 Add Endstop Noise Filter
Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-05-21 15:32:26 -05:00
Scott Lahteine
7ee1ab4fd3 Add Bézier Jerk Control option 2018-05-08 09:21:54 -05:00
Scott Lahteine
5735c8af5b
[1.1.x] Arrange LCD options by type (#10631)
* Bump configuration versions to 010109
* Arrange LCD options by type
2018-05-06 19:17:29 -05:00
Scott Lahteine
b50afa9897 Add thermocouple with AD8495 support
Co-Authored-By: Dmitriy <demonx@demonx.ru>
2018-05-02 08:41:31 -05:00
Scott Lahteine
0b9f99f940 LCD_BED_LEVELING enables a sub-menu for ABL 2018-05-01 04:41:56 -05:00
Scott Lahteine
542baea2e1 Add units to probe speed comments 2018-04-30 23:45:34 -05:00
Scott Lahteine
1025066ab1 Add NO_LCD_MENUS to display only the Status Screen 2018-04-30 18:39:32 -05:00
Scott Lahteine
6b50a50676
Extra options for LEVEL_BED_CORNERS (#10484) 2018-04-22 02:30:20 -05:00
Festivejelly
61f9e28c23 [1.1.x] Wait for bed heaters between probing (#9890) 2018-04-21 15:44:07 -05:00
Scott Lahteine
090d72f591
[1.1.x] Add optional menu item to toggle software endstops (#10392) 2018-04-13 00:24:20 -05:00
Scott Lahteine
4f660a18bc Add Z_PROBE_LOW_POINT to prevent damage 2018-04-09 17:22:28 -05:00
Scott Lahteine
56b5fb5e15 Update Bed PID config comments 2018-04-08 06:46:05 -05:00
Lenbok
0aa833fe6c Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:44 -05:00
Scott Lahteine
be098cd42f Z Endstop Servo => Z Probe Servo 2018-04-01 23:54:47 -05:00
Scott Lahteine
cf4e2e507f Consolidate 3-point leveling point options 2018-03-19 01:55:51 -05:00
Scott Lahteine
f7de05e50c General spacing cleanup 2018-03-17 16:51:34 -05:00
Scott Lahteine
e63cb5fe8f
[1.1.x] Make MIN_PROBE_EDGE a general option (for electronic probes) (#10068)
Some probes don't work near the edges of the bed. This change promotes MIN_PROBE_EDGE to a general setting that applies to all probing functions.
2018-03-13 01:15:29 -05:00
Scott Lahteine
0aa100a31e Add Z_AFTER_PROBING option
Some fix-mounted probes need manual stowing. And after probing some may prefer to raise or lower the nozzle. This restores an old option but tailors it to allow raise or lower as preferred.
2018-03-11 09:48:02 -05:00
Scott Lahteine
1b79217fbc Add UNKNOWN_Z_NO_RAISE option
With this option enabled, Z won't ever be raised until after `G28` has been completed, and it won't raise if Z becomes unknown. This is good for machines whose beds fall when Z is powered off.
2018-03-09 23:11:35 -06:00
Scott Lahteine
3cdd2591ed Update custom boot screen description 2018-03-03 20:10:35 -06:00
Scott Lahteine
8488d64062 Standardize encoder defaults 2018-02-24 22:37:55 -06:00
Scott Lahteine
8c22f9fd4f Bring some example configs up to speed 2018-02-24 22:00:15 -06:00
Scott Lahteine
5299b577d1
Spanish (UTF8) Language (#9785)
From #7314 by @MrAmericanMike
2018-02-23 20:23:35 -06:00
Scott Lahteine
921001f004 Add RESTORE_LEVELING_AFTER_G28 option
Reference #8670
2018-02-23 12:42:17 -06:00
Scott Lahteine
18881e6725 Add 20x4 option for Sainsmart LCD 2018-02-20 20:09:49 -06:00
Scott Lahteine
c04f8e8c9d Support for multiple filament runout sensors 2018-02-19 06:25:35 -06:00
Scott Lahteine
4813938a87 Update configs for 2.0.x parity 2018-02-18 19:42:20 -06:00
Scott Lahteine
d7e2e655ca Followup to #9663 2018-02-16 02:14:20 -06:00
Scott Lahteine
2ec90d2162 Followup to #9663
`ENABLED` only works for flag type options. Floats must use `#ifdef`.
2018-02-15 22:23:27 -06:00
Roxy-3D
c8d3069580
UBL - Allow user to control Z-Height correction for off mesh movements (#9663)
* UBL - Allow user to control Z-Height correction for off mesh movements

* Enable UBL_Z_RAISE_WHEN_OFF_MESH on test machine for time being
2018-02-15 19:23:01 -06:00
Christopher Reimer
254417e8b0 Enable and disable power supply automatically 2018-02-06 00:20:33 -06:00
Project-J²
ae2476dfdb Add UltiController v2.1 support
Add compatibility with the original screen bord from Ultimaker 2 printer
(UltiController v2.1 with the PG-2864ALBP I2C display)
2018-02-05 22:24:08 -06:00
Scott Lahteine
ca58084020 Add MALYAN_LCD to configurations 2018-02-04 21:18:42 -06:00
Scott Lahteine
3d9f360b5a Better probe boundaries for linear/grid 2018-01-22 01:10:34 -06:00
Scott Lahteine
957bb3124a Add thermistor 15 tuned for JGAurora A5 2018-01-21 16:57:47 -06:00
Scott Lahteine
69c993092b Followup to Ender config 2018-01-15 05:48:50 -06:00
Scott Lahteine
885200f833 Bring other configs up-to-date 2018-01-11 01:03:34 -06:00
GMagician
5903b002ac 1.1.x semitec 104NT-4 added (#9120)
Table is very very similar to old 104-GT2 so I added only the name and recycled old ID
2018-01-09 16:53:44 -06:00
Scott Lahteine
839dd66c3b Synchronize configs with 2.0.x 2017-12-31 00:02:22 -06:00
Thomas Moore
59d047c1d7 [1.1.x] Use NOZZLE_PARK_FEATURE for ADVANCED_PAUSE_FEATURE (#8864)
* Use NOZZLE_PARK_FEATURE for ADVANCED_PAUSE_FEATURE
2017-12-24 23:47:05 -06:00
Scott Lahteine
88c0688961 Reduce default jerk. XY by half. Z by 1/4 2017-12-24 19:49:51 -06:00
Dan Delaney
df8420aa62 Adding support for using the MKS_12864OLED with the SSD1306 controller 2017-12-16 17:44:34 -06:00
Dan Delaney
5249765508 Adding support for the Tronxy and Zonestar LCD
Code borrowed and modified from erikkallen/Marlin_tronxy.
Changed the ANET_KEYPAD_LCD to zonestar, since it is the same device.
I kept a define for ANET_KEYPAD_LCD to enable ZONESTAR_LCD.
2017-12-15 19:13:31 -06:00
Scott Lahteine
666d95285b Mention that segments interpolate more 2017-12-09 06:18:41 -06:00
Scott Lahteine
6eb268f63f Remove old UBL description text 2017-12-08 17:52:44 -06:00
Scott Lahteine
44800e9899 PROBE_DOUBLE_TOUCH => MULTIPLE_PROBING 2017-12-07 16:46:06 -06:00
Scott Lahteine
794f8f1329 Update K1 => PID_K1 2017-12-05 19:59:01 -06:00
Scott Lahteine
172ce67344 New feature: BED_SKEW_CORRECTION 2017-12-01 19:43:32 -06:00