mirror of
https://github.com/MarlinFirmware/Marlin.git
synced 2024-11-27 13:56:24 +00:00
824f71d503
Original Mesh Bed Leveling replacement put at top of UBL Menu Options to help facilitate the removal of the Original Mesh Bed Leveling. Radar display (and control) of the UBL Interactive Mesh Editing.
1841 lines
78 KiB
C++
1841 lines
78 KiB
C++
/**
|
|
* Marlin 3D Printer Firmware
|
|
* Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
|
|
*
|
|
* Based on Sprinter and grbl.
|
|
* Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm
|
|
*
|
|
* This program is free software: you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation, either version 3 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*
|
|
*/
|
|
|
|
#include "MarlinConfig.h"
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
#include "ubl.h"
|
|
#include "Marlin.h"
|
|
#include "hex_print_routines.h"
|
|
#include "configuration_store.h"
|
|
#include "ultralcd.h"
|
|
#include "stepper.h"
|
|
#include "planner.h"
|
|
#include "gcode.h"
|
|
|
|
#include <math.h>
|
|
#include "least_squares_fit.h"
|
|
|
|
#define UBL_G29_P31
|
|
|
|
extern float destination[XYZE], current_position[XYZE];
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
void lcd_return_to_status();
|
|
void lcd_mesh_edit_setup(float initial);
|
|
float lcd_mesh_edit();
|
|
void lcd_z_offset_edit_setup(float);
|
|
#ifdef DOGLCD
|
|
extern void _lcd_ubl_output_map_lcd();
|
|
#endif
|
|
float lcd_z_offset_edit();
|
|
#endif
|
|
|
|
extern float meshedit_done;
|
|
extern long babysteps_done;
|
|
extern float probe_pt(const float &x, const float &y, bool, int);
|
|
extern bool set_probe_deployed(bool);
|
|
extern void set_bed_leveling_enabled(bool);
|
|
extern bool ubl_lcd_map_control;
|
|
typedef void (*screenFunc_t)();
|
|
extern void lcd_goto_screen(screenFunc_t screen, const uint32_t encoder = 0);
|
|
|
|
#define SIZE_OF_LITTLE_RAISE 1
|
|
#define BIG_RAISE_NOT_NEEDED 0
|
|
|
|
int unified_bed_leveling::g29_verbose_level,
|
|
unified_bed_leveling::g29_phase_value,
|
|
unified_bed_leveling::g29_repetition_cnt,
|
|
unified_bed_leveling::g29_storage_slot = 0,
|
|
unified_bed_leveling::g29_map_type,
|
|
unified_bed_leveling::g29_grid_size;
|
|
bool unified_bed_leveling::g29_c_flag,
|
|
unified_bed_leveling::g29_x_flag,
|
|
unified_bed_leveling::g29_y_flag;
|
|
float unified_bed_leveling::g29_x_pos,
|
|
unified_bed_leveling::g29_y_pos,
|
|
unified_bed_leveling::g29_card_thickness = 0.0,
|
|
unified_bed_leveling::g29_constant = 0.0;
|
|
|
|
/**
|
|
* G29: Unified Bed Leveling by Roxy
|
|
*
|
|
* Parameters understood by this leveling system:
|
|
*
|
|
* A Activate Activate the Unified Bed Leveling system.
|
|
*
|
|
* B # Business Use the 'Business Card' mode of the Manual Probe subsystem. This is invoked as
|
|
* G29 P2 B. The mode of G29 P2 allows you to use a business card or recipe card
|
|
* as a shim that the nozzle will pinch as it is lowered. The idea is that you
|
|
* can easily feel the nozzle getting to the same height by the amount of resistance
|
|
* the business card exhibits to movement. You should try to achieve the same amount
|
|
* of resistance on each probed point to facilitate accurate and repeatable measurements.
|
|
* You should be very careful not to drive the nozzle into the business card with a
|
|
* lot of force as it is very possible to cause damage to your printer if your are
|
|
* careless. If you use the B option with G29 P2 B you can omit the numeric value
|
|
* on first use to measure the business card's thickness. Subsequent usage of 'B'
|
|
* will apply the previously-measured thickness as the default.
|
|
* Note: A non-compressible Spark Gap feeler gauge is recommended over a Business Card.
|
|
*
|
|
* C Continue Continue, Constant, Current Location. This is not a primary command. C is used to
|
|
* further refine the behaviour of several other commands. Issuing a G29 P1 C will
|
|
* continue the generation of a partially constructed Mesh without invalidating what has
|
|
* been done. Issuing a G29 P2 C will tell the Manual Probe subsystem to use the current
|
|
* location in its search for the closest unmeasured Mesh Point. When used with a G29 Z C
|
|
* it indicates to use the current location instead of defaulting to the center of the print bed.
|
|
*
|
|
* D Disable Disable the Unified Bed Leveling system.
|
|
*
|
|
* E Stow_probe Stow the probe after each sampled point.
|
|
*
|
|
* F # Fade Fade the amount of Mesh Based Compensation over a specified height. At the
|
|
* specified height, no correction is applied and natural printer kenimatics take over. If no
|
|
* number is specified for the command, 10mm is assumed to be reasonable.
|
|
*
|
|
* H # Height Specify the Height to raise the nozzle after each manual probe of the bed. The
|
|
* default is 5mm.
|
|
*
|
|
* I # Invalidate Invalidate specified number of Mesh Points. The nozzle location is used unless
|
|
* the X and Y parameter are used. If no number is specified, only the closest Mesh
|
|
* point to the location is invalidated. The 'T' parameter is also available to produce
|
|
* a map after the operation. This command is useful to invalidate a portion of the
|
|
* Mesh so it can be adjusted using other tools in the Unified Bed Leveling System. When
|
|
* attempting to invalidate an isolated bad point in the mesh, the 'T' option will indicate
|
|
* where the nozzle is positioned in the Mesh with (#). You can move the nozzle around on
|
|
* the bed and use this feature to select the center of the area (or cell) you want to
|
|
* invalidate.
|
|
*
|
|
* J # Grid Perform a Grid Based Leveling of the current Mesh using a grid with n points on a side.
|
|
* Not specifying a grid size will invoke the 3-Point leveling function.
|
|
*
|
|
* K # Kompare Kompare current Mesh with stored Mesh # replacing current Mesh with the result. This
|
|
* command literally performs a diff between two Meshes.
|
|
*
|
|
* L Load Load Mesh from the previously activated location in the EEPROM.
|
|
*
|
|
* L # Load Load Mesh from the specified location in the EEPROM. Set this location as activated
|
|
* for subsequent Load and Store operations.
|
|
*
|
|
* The P or Phase commands are used for the bulk of the work to setup a Mesh. In general, your Mesh will
|
|
* start off being initialized with a G29 P0 or a G29 P1. Further refinement of the Mesh happens with
|
|
* each additional Phase that processes it.
|
|
*
|
|
* P0 Phase 0 Zero Mesh Data and turn off the Mesh Compensation System. This reverts the
|
|
* 3D Printer to the same state it was in before the Unified Bed Leveling Compensation
|
|
* was turned on. Setting the entire Mesh to Zero is a special case that allows
|
|
* a subsequent G or T leveling operation for backward compatibility.
|
|
*
|
|
* P1 Phase 1 Invalidate entire Mesh and continue with automatic generation of the Mesh data using
|
|
* the Z-Probe. Usually the probe can't reach all areas that the nozzle can reach. On
|
|
* Cartesian printers, points within the X_PROBE_OFFSET_FROM_EXTRUDER and Y_PROBE_OFFSET_FROM_EXTRUDER
|
|
* area cannot be automatically probed. For Delta printers the area in which DELTA_PROBEABLE_RADIUS
|
|
* and DELTA_PRINTABLE_RADIUS do not overlap will not be automatically probed.
|
|
*
|
|
* These points will be handled in Phase 2 and Phase 3. If the Phase 1 command is given the
|
|
* C (Continue) parameter it does not invalidate the Mesh prior to automatically
|
|
* probing needed locations. This allows you to invalidate portions of the Mesh but still
|
|
* use the automatic probing capabilities of the Unified Bed Leveling System. An X and Y
|
|
* parameter can be given to prioritize where the command should be trying to measure points.
|
|
* If the X and Y parameters are not specified the current probe position is used.
|
|
* P1 accepts a 'T' (Topology) parameter so you can observe mesh generation.
|
|
* P1 also watches for the LCD Panel Encoder Switch to be held down (assuming you have one),
|
|
* and will suspend generation of the Mesh in that case. (Note: This check is only done
|
|
* between probe points, so you must press and hold the switch until the Phase 1 command
|
|
* detects it.)
|
|
*
|
|
* P2 Phase 2 Probe areas of the Mesh that can't be automatically handled. Phase 2 respects an H
|
|
* parameter to control the height between Mesh points. The default height for movement
|
|
* between Mesh points is 5mm. A smaller number can be used to make this part of the
|
|
* calibration less time consuming. You will be running the nozzle down until it just barely
|
|
* touches the glass. You should have the nozzle clean with no plastic obstructing your view.
|
|
* Use caution and move slowly. It is possible to damage your printer if you are careless.
|
|
* Note that this command will use the configuration #define SIZE_OF_LITTLE_RAISE if the
|
|
* nozzle is moving a distance of less than BIG_RAISE_NOT_NEEDED.
|
|
*
|
|
* The H parameter can be set negative if your Mesh dips in a large area. You can press
|
|
* and hold the LCD Panel's encoder wheel to terminate the current Phase 2 command. You
|
|
* can then re-issue the G29 P 2 command with an H parameter that is more suitable for the
|
|
* area you are manually probing. Note that the command tries to start you in a corner
|
|
* of the bed where movement will be predictable. You can force the location to be used in
|
|
* the distance calculations by using the X and Y parameters. You may find it is helpful to
|
|
* print out a Mesh Map (G29 T) to understand where the mesh is invalidated and where
|
|
* the nozzle will need to move in order to complete the command. The C parameter is
|
|
* available on the Phase 2 command also and indicates the search for points to measure should
|
|
* be done based on the current location of the nozzle.
|
|
*
|
|
* A B parameter is also available for this command and described up above. It places the
|
|
* manual probe subsystem into Business Card mode where the thickness of a business card is
|
|
* measured and then used to accurately set the nozzle height in all manual probing for the
|
|
* duration of the command. (S for Shim mode would be a better parameter name, but S is needed
|
|
* for Save or Store of the Mesh to EEPROM) A Business card can be used, but you will have
|
|
* better results if you use a flexible Shim that does not compress very much. That makes it
|
|
* easier for you to get the nozzle to press with similar amounts of force against the shim so you
|
|
* can get accurate measurements. As you are starting to touch the nozzle against the shim try
|
|
* to get it to grasp the shim with the same force as when you measured the thickness of the
|
|
* shim at the start of the command.
|
|
*
|
|
* Phase 2 allows the T (Map) parameter to be specified. This helps the user see the progression
|
|
* of the Mesh being built.
|
|
*
|
|
* NOTE: P2 is not available unless you have LCD support enabled!
|
|
*
|
|
* P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value. There are two different paths the
|
|
* user can go down. If the user specifies the value using the C parameter, the closest invalid
|
|
* mesh points to the nozzle will be filled. The user can specify a repeat count using the R
|
|
* parameter with the C version of the command.
|
|
*
|
|
* A second version of the fill command is available if no C constant is specified. Not
|
|
* specifying a C constant will invoke the 'Smart Fill' algorithm. The G29 P3 command will search
|
|
* from the edges of the mesh inward looking for invalid mesh points. It will look at the next
|
|
* several mesh points to determine if the print bed is sloped up or down. If the bed is sloped
|
|
* upward from the invalid mesh point, it will be replaced with the value of the nearest mesh point.
|
|
* If the bed is sloped downward from the invalid mesh point, it will be replaced with a value that
|
|
* puts all three points in a line. The second version of the G29 P3 command is a quick, easy and
|
|
* usually safe way to populate the unprobed regions of your mesh so you can continue to the G26
|
|
* Mesh Validation Pattern phase. Please note that you are populating your mesh with unverified
|
|
* numbers. You should use some scrutiny and caution.
|
|
*
|
|
* P4 Phase 4 Fine tune the Mesh. The Delta Mesh Compensation System assume the existence of
|
|
* an LCD Panel. It is possible to fine tune the mesh without the use of an LCD Panel using
|
|
* G42 and M421; see the UBL documentation for further details.
|
|
*
|
|
* The System will search for the closest Mesh Point to the nozzle. It will move the
|
|
* nozzle to this location. The user can use the LCD Panel to carefully adjust the nozzle
|
|
* so it is just barely touching the bed. When the user clicks the control, the System
|
|
* will lock in that height for that point in the Mesh Compensation System.
|
|
*
|
|
* Phase 4 has several additional parameters that the user may find helpful. Phase 4
|
|
* can be started at a specific location by specifying an X and Y parameter. Phase 4
|
|
* can be requested to continue the adjustment of Mesh Points by using the R(epeat)
|
|
* parameter. If the Repetition count is not specified, it is assumed the user wishes
|
|
* to adjust the entire matrix. The nozzle is moved to the Mesh Point being edited.
|
|
* The command can be terminated early (or after the area of interest has been edited) by
|
|
* pressing and holding the encoder wheel until the system recognizes the exit request.
|
|
* Phase 4's general form is G29 P4 [R # of points] [X position] [Y position]
|
|
*
|
|
* Phase 4 is intended to be used with the G26 Mesh Validation Command. Using the
|
|
* information left on the printer's bed from the G26 command it is very straight forward
|
|
* and easy to fine tune the Mesh. One concept that is important to remember and that
|
|
* will make using the Phase 4 command easy to use is this: You are editing the Mesh Points.
|
|
* If you have too little clearance and not much plastic was extruded in an area, you want to
|
|
* LOWER the Mesh Point at the location. If you did not get good adheasion, you want to
|
|
* RAISE the Mesh Point at that location.
|
|
*
|
|
* NOTE: P4 is not available unless you have LCD support enabled!
|
|
*
|
|
* P5 Phase 5 Find Mean Mesh Height and Standard Deviation. Typically, it is easier to use and
|
|
* work with the Mesh if it is Mean Adjusted. You can specify a C parameter to
|
|
* Correct the Mesh to a 0.00 Mean Height. Adding a C parameter will automatically
|
|
* execute a G29 P6 C <mean height>.
|
|
*
|
|
* P6 Phase 6 Shift Mesh height. The entire Mesh's height is adjusted by the height specified
|
|
* with the C parameter. Being able to adjust the height of a Mesh is useful tool. It
|
|
* can be used to compensate for poorly calibrated Z-Probes and other errors. Ideally,
|
|
* you should have the Mesh adjusted for a Mean Height of 0.00 and the Z-Probe measuring
|
|
* 0.000 at the Z Home location.
|
|
*
|
|
* Q Test Load specified Test Pattern to assist in checking correct operation of system. This
|
|
* command is not anticipated to be of much value to the typical user. It is intended
|
|
* for developers to help them verify correct operation of the Unified Bed Leveling System.
|
|
*
|
|
* R # Repeat Repeat this command the specified number of times. If no number is specified the
|
|
* command will be repeated GRID_MAX_POINTS_X * GRID_MAX_POINTS_Y times.
|
|
*
|
|
* S Store Store the current Mesh in the Activated area of the EEPROM. It will also store the
|
|
* current state of the Unified Bed Leveling system in the EEPROM.
|
|
*
|
|
* S # Store Store the current Mesh at the specified location in EEPROM. Activate this location
|
|
* for subsequent Load and Store operations. Valid storage slot numbers begin at 0 and
|
|
* extend to a limit related to the available EEPROM storage.
|
|
*
|
|
* S -1 Store Store the current Mesh as a print out that is suitable to be feed back into the system
|
|
* at a later date. The GCode output can be saved and later replayed by the host software
|
|
* to reconstruct the current mesh on another machine.
|
|
*
|
|
* T Topology Display the Mesh Map Topology.
|
|
* 'T' can be used alone (e.g., G29 T) or in combination with most of the other commands.
|
|
* This option works with all Phase commands (e.g., G29 P4 R 5 T X 50 Y100 C -.1 O)
|
|
* This parameter can also specify a Map Type. T0 (the default) is user-readable. T1 can
|
|
* is suitable to paste into a spreadsheet for a 3D graph of the mesh.
|
|
*
|
|
* U Unlevel Perform a probe of the outer perimeter to assist in physically leveling unlevel beds.
|
|
* Only used for G29 P1 T U. This speeds up the probing of the edge of the bed. Useful
|
|
* when the entire bed doesn't need to be probed because it will be adjusted.
|
|
*
|
|
* V # Verbosity Set the verbosity level (0-4) for extra details. (Default 0)
|
|
*
|
|
* W What? Display valuable Unified Bed Leveling System data.
|
|
*
|
|
* X # X Location for this command
|
|
*
|
|
* Y # Y Location for this command
|
|
*
|
|
*
|
|
* Release Notes:
|
|
* You MUST do M502, M500 to initialize the storage. Failure to do this will cause all
|
|
* kinds of problems. Enabling EEPROM Storage is highly recommended. With EEPROM Storage
|
|
* of the mesh, you are limited to 3-Point and Grid Leveling. (G29 P0 T and G29 P0 G
|
|
* respectively.)
|
|
*
|
|
* When you do a G28 and then a G29 P1 to automatically build your first mesh, you are going to notice
|
|
* the Unified Bed Leveling probes points further and further away from the starting location. (The
|
|
* starting location defaults to the center of the bed.) The original Grid and Mesh leveling used
|
|
* a Zig Zag pattern. The new pattern is better, especially for people with Delta printers. This
|
|
* allows you to get the center area of the Mesh populated (and edited) quicker. This allows you to
|
|
* perform a small print and check out your settings quicker. You do not need to populate the
|
|
* entire mesh to use it. (You don't want to spend a lot of time generating a mesh only to realize
|
|
* you don't have the resolution or zprobe_zoffset set correctly. The Mesh generation
|
|
* gathers points closest to where the nozzle is located unless you specify an (X,Y) coordinate pair.
|
|
*
|
|
* The Unified Bed Leveling uses a lot of EEPROM storage to hold its data. And it takes some effort
|
|
* to get this Mesh data correct for a user's printer. We do not want this data destroyed as
|
|
* new versions of Marlin add or subtract to the items stored in EEPROM. So, for the benefit of
|
|
* the users, we store the Mesh data at the end of the EEPROM and do not keep it contiguous with the
|
|
* other data stored in the EEPROM. (For sure the developers are going to complain about this, but
|
|
* this is going to be helpful to the users!)
|
|
*
|
|
* The foundation of this Bed Leveling System is built on Epatel's Mesh Bed Leveling code. A big
|
|
* 'Thanks!' to him and the creators of 3-Point and Grid Based leveling. Combining their contributions
|
|
* we now have the functionality and features of all three systems combined.
|
|
*/
|
|
|
|
void unified_bed_leveling::G29() {
|
|
|
|
if (!settings.calc_num_meshes()) {
|
|
SERIAL_PROTOCOLLNPGM("?You need to enable your EEPROM and initialize it");
|
|
SERIAL_PROTOCOLLNPGM("with M502, M500, M501 in that order.\n");
|
|
return;
|
|
}
|
|
|
|
// Check for commands that require the printer to be homed
|
|
if (axis_unhomed_error()) {
|
|
const int8_t p_val = parser.seen('P') && parser.has_value() ? parser.value_int() : -1;
|
|
if (p_val == 1 || p_val == 2 || p_val == 4 || parser.seen('J'))
|
|
home_all_axes();
|
|
}
|
|
|
|
if (g29_parameter_parsing()) return; // abort if parsing the simple parameters causes a problem,
|
|
|
|
// Invalidate Mesh Points. This command is a little bit asymmetrical because
|
|
// it directly specifies the repetition count and does not use the 'R' parameter.
|
|
if (parser.seen('I')) {
|
|
uint8_t cnt = 0;
|
|
g29_repetition_cnt = parser.has_value() ? parser.value_int() : 1;
|
|
if (g29_repetition_cnt >= GRID_MAX_POINTS) {
|
|
set_all_mesh_points_to_value(NAN);
|
|
} else {
|
|
while (g29_repetition_cnt--) {
|
|
if (cnt > 20) { cnt = 0; idle(); }
|
|
const mesh_index_pair location = find_closest_mesh_point_of_type(REAL, g29_x_pos, g29_y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false);
|
|
if (location.x_index < 0) {
|
|
// No more REACHABLE mesh points to invalidate, so we ASSUME the user
|
|
// meant to invalidate the ENTIRE mesh, which cannot be done with
|
|
// find_closest_mesh_point loop which only returns REACHABLE points.
|
|
set_all_mesh_points_to_value(NAN);
|
|
SERIAL_PROTOCOLLNPGM("Entire Mesh invalidated.\n");
|
|
break; // No more invalid Mesh Points to populate
|
|
}
|
|
z_values[location.x_index][location.y_index] = NAN;
|
|
cnt++;
|
|
}
|
|
}
|
|
SERIAL_PROTOCOLLNPGM("Locations invalidated.\n");
|
|
}
|
|
|
|
if (parser.seen('Q')) {
|
|
const int test_pattern = parser.has_value() ? parser.value_int() : -99;
|
|
if (!WITHIN(test_pattern, -1, 2)) {
|
|
SERIAL_PROTOCOLLNPGM("Invalid test_pattern value. (-1 to 2)\n");
|
|
return;
|
|
}
|
|
SERIAL_PROTOCOLLNPGM("Loading test_pattern values.\n");
|
|
switch (test_pattern) {
|
|
case -1:
|
|
g29_eeprom_dump();
|
|
break;
|
|
case 0:
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a bowl shape - similar to
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) { // a poorly calibrated Delta.
|
|
const float p1 = 0.5 * (GRID_MAX_POINTS_X) - x,
|
|
p2 = 0.5 * (GRID_MAX_POINTS_Y) - y;
|
|
z_values[x][y] += 2.0 * HYPOT(p1, p2);
|
|
}
|
|
}
|
|
break;
|
|
case 1:
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a diagonal line several Mesh cells thick that is raised
|
|
z_values[x][x] += 9.999;
|
|
z_values[x][x + (x < GRID_MAX_POINTS_Y - 1) ? 1 : -1] += 9.999; // We want the altered line several mesh points thick
|
|
}
|
|
break;
|
|
case 2:
|
|
// Allow the user to specify the height because 10mm is a little extreme in some cases.
|
|
for (uint8_t x = (GRID_MAX_POINTS_X) / 3; x < 2 * (GRID_MAX_POINTS_X) / 3; x++) // Create a rectangular raised area in
|
|
for (uint8_t y = (GRID_MAX_POINTS_Y) / 3; y < 2 * (GRID_MAX_POINTS_Y) / 3; y++) // the center of the bed
|
|
z_values[x][y] += parser.seen('C') ? g29_constant : 9.99;
|
|
break;
|
|
}
|
|
}
|
|
|
|
if (parser.seen('J')) {
|
|
if (g29_grid_size) { // if not 0 it is a normal n x n grid being probed
|
|
save_ubl_active_state_and_disable();
|
|
tilt_mesh_based_on_probed_grid(parser.seen('T'));
|
|
restore_ubl_active_state_and_leave();
|
|
}
|
|
else { // grid_size == 0 : A 3-Point leveling has been requested
|
|
float z3, z2, z1 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y), false, g29_verbose_level);
|
|
if (!isnan(z1)) {
|
|
z2 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y), false, g29_verbose_level);
|
|
if (!isnan(z2))
|
|
z3 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y), true, g29_verbose_level);
|
|
}
|
|
|
|
if (isnan(z1) || isnan(z2) || isnan(z3)) { // probe_pt will return NAN if unreachable
|
|
SERIAL_ERROR_START();
|
|
SERIAL_ERRORLNPGM("Attempt to probe off the bed.");
|
|
goto LEAVE;
|
|
}
|
|
|
|
// Adjust z1, z2, z3 by the Mesh Height at these points. Just because they're non-zero
|
|
// doesn't mean the Mesh is tilted! (Compensate each probe point by what the Mesh says
|
|
// its height is.)
|
|
|
|
save_ubl_active_state_and_disable();
|
|
z1 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y)) /* + zprobe_zoffset */ ;
|
|
z2 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y)) /* + zprobe_zoffset */ ;
|
|
z3 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y)) /* + zprobe_zoffset */ ;
|
|
|
|
do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y)));
|
|
tilt_mesh_based_on_3pts(z1, z2, z3);
|
|
restore_ubl_active_state_and_leave();
|
|
}
|
|
}
|
|
|
|
if (parser.seen('P')) {
|
|
if (WITHIN(g29_phase_value, 0, 1) && state.storage_slot == -1) {
|
|
state.storage_slot = 0;
|
|
SERIAL_PROTOCOLLNPGM("Default storage slot 0 selected.");
|
|
}
|
|
|
|
switch (g29_phase_value) {
|
|
case 0:
|
|
//
|
|
// Zero Mesh Data
|
|
//
|
|
reset();
|
|
SERIAL_PROTOCOLLNPGM("Mesh zeroed.");
|
|
break;
|
|
|
|
case 1:
|
|
//
|
|
// Invalidate Entire Mesh and Automatically Probe Mesh in areas that can be reached by the probe
|
|
//
|
|
if (!parser.seen('C')) {
|
|
invalidate();
|
|
SERIAL_PROTOCOLLNPGM("Mesh invalidated. Probing mesh.");
|
|
}
|
|
if (g29_verbose_level > 1) {
|
|
SERIAL_PROTOCOLPAIR("Probing Mesh Points Closest to (", g29_x_pos);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL(g29_y_pos);
|
|
SERIAL_PROTOCOLLNPGM(").\n");
|
|
}
|
|
probe_entire_mesh(g29_x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, g29_y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER,
|
|
parser.seen('T'), parser.seen('E'), parser.seen('U'));
|
|
break;
|
|
|
|
case 2: {
|
|
#if ENABLED(NEWPANEL)
|
|
//
|
|
// Manually Probe Mesh in areas that can't be reached by the probe
|
|
//
|
|
SERIAL_PROTOCOLLNPGM("Manually probing unreachable mesh locations.");
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
if (!g29_x_flag && !g29_y_flag) {
|
|
/**
|
|
* Use a good default location for the path.
|
|
* The flipped > and < operators in these comparisons is intentional.
|
|
* It should cause the probed points to follow a nice path on Cartesian printers.
|
|
* It may make sense to have Delta printers default to the center of the bed.
|
|
* Until that is decided, this can be forced with the X and Y parameters.
|
|
*/
|
|
#if IS_KINEMATIC
|
|
g29_x_pos = X_HOME_POS;
|
|
g29_y_pos = Y_HOME_POS;
|
|
#else // cartesian
|
|
g29_x_pos = X_PROBE_OFFSET_FROM_EXTRUDER > 0 ? X_MAX_POS : X_MIN_POS;
|
|
g29_y_pos = Y_PROBE_OFFSET_FROM_EXTRUDER < 0 ? Y_MAX_POS : Y_MIN_POS;
|
|
#endif
|
|
}
|
|
|
|
if (parser.seen('C')) {
|
|
g29_x_pos = current_position[X_AXIS];
|
|
g29_y_pos = current_position[Y_AXIS];
|
|
}
|
|
|
|
float height = Z_CLEARANCE_BETWEEN_PROBES;
|
|
|
|
if (parser.seen('B')) {
|
|
g29_card_thickness = parser.has_value() ? parser.value_float() : measure_business_card_thickness(height);
|
|
if (fabs(g29_card_thickness) > 1.5) {
|
|
SERIAL_PROTOCOLLNPGM("?Error in Business Card measurement.");
|
|
return;
|
|
}
|
|
}
|
|
|
|
if (parser.seen('H') && parser.has_value()) height = parser.value_float();
|
|
|
|
if (!position_is_reachable_xy(g29_x_pos, g29_y_pos)) {
|
|
SERIAL_PROTOCOLLNPGM("XY outside printable radius.");
|
|
return;
|
|
}
|
|
|
|
manually_probe_remaining_mesh(g29_x_pos, g29_y_pos, height, g29_card_thickness, parser.seen('T'));
|
|
SERIAL_PROTOCOLLNPGM("G29 P2 finished.");
|
|
#else
|
|
SERIAL_PROTOCOLLNPGM("?P2 is only available when an LCD is present.");
|
|
return;
|
|
#endif
|
|
} break;
|
|
|
|
case 3: {
|
|
/**
|
|
* Populate invalid mesh areas. Proceed with caution.
|
|
* Two choices are available:
|
|
* - Specify a constant with the 'C' parameter.
|
|
* - Allow 'G29 P3' to choose a 'reasonable' constant.
|
|
*/
|
|
|
|
if (g29_c_flag) {
|
|
if (g29_repetition_cnt >= GRID_MAX_POINTS) {
|
|
set_all_mesh_points_to_value(g29_constant);
|
|
}
|
|
else {
|
|
while (g29_repetition_cnt--) { // this only populates reachable mesh points near
|
|
const mesh_index_pair location = find_closest_mesh_point_of_type(INVALID, g29_x_pos, g29_y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false);
|
|
if (location.x_index < 0) {
|
|
// No more REACHABLE INVALID mesh points to populate, so we ASSUME
|
|
// user meant to populate ALL INVALID mesh points to value
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) {
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) {
|
|
if ( isnan(z_values[x][y])) {
|
|
z_values[x][y] = g29_constant;
|
|
}
|
|
}
|
|
}
|
|
break; // No more invalid Mesh Points to populate
|
|
}
|
|
z_values[location.x_index][location.y_index] = g29_constant;
|
|
}
|
|
}
|
|
} else {
|
|
const float cvf = parser.value_float();
|
|
switch((int)truncf(cvf * 10.0) - 30) { // 3.1 -> 1
|
|
#if ENABLED(UBL_G29_P31)
|
|
case 1: {
|
|
|
|
// P3.1 use least squares fit to fill missing mesh values
|
|
// P3.10 zero weighting for distance, all grid points equal, best fit tilted plane
|
|
// P3.11 10X weighting for nearest grid points versus farthest grid points
|
|
// P3.12 100X distance weighting
|
|
// P3.13 1000X distance weighting, approaches simple average of nearest points
|
|
|
|
const float weight_power = (cvf - 3.10) * 100.0, // 3.12345 -> 2.345
|
|
weight_factor = weight_power ? pow(10.0, weight_power) : 0;
|
|
smart_fill_wlsf(weight_factor);
|
|
}
|
|
break;
|
|
#endif
|
|
case 0: // P3 or P3.0
|
|
default: // and anything P3.x that's not P3.1
|
|
smart_fill_mesh(); // Do a 'Smart' fill using nearby known values
|
|
break;
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
|
|
case 4: // Fine Tune (i.e., Edit) the Mesh
|
|
#if ENABLED(NEWPANEL)
|
|
fine_tune_mesh(g29_x_pos, g29_y_pos, parser.seen('T'));
|
|
#else
|
|
SERIAL_PROTOCOLLNPGM("?P4 is only available when an LCD is present.");
|
|
return;
|
|
#endif
|
|
break;
|
|
|
|
case 5: find_mean_mesh_height(); break;
|
|
|
|
case 6: shift_mesh_height(); break;
|
|
}
|
|
}
|
|
|
|
//
|
|
// Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
|
|
// good to have the extra information. Soon... we prune this to just a few items
|
|
//
|
|
if (parser.seen('W')) g29_what_command();
|
|
|
|
//
|
|
// When we are fully debugged, this may go away. But there are some valid
|
|
// use cases for the users. So we can wait and see what to do with it.
|
|
//
|
|
|
|
if (parser.seen('K')) // Kompare Current Mesh Data to Specified Stored Mesh
|
|
g29_compare_current_mesh_to_stored_mesh();
|
|
|
|
//
|
|
// Load a Mesh from the EEPROM
|
|
//
|
|
|
|
if (parser.seen('L')) { // Load Current Mesh Data
|
|
g29_storage_slot = parser.has_value() ? parser.value_int() : state.storage_slot;
|
|
|
|
int16_t a = settings.calc_num_meshes();
|
|
|
|
if (!a) {
|
|
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available.");
|
|
return;
|
|
}
|
|
|
|
if (!WITHIN(g29_storage_slot, 0, a - 1)) {
|
|
SERIAL_PROTOCOLLNPGM("?Invalid storage slot.");
|
|
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
|
|
return;
|
|
}
|
|
|
|
settings.load_mesh(g29_storage_slot);
|
|
state.storage_slot = g29_storage_slot;
|
|
|
|
SERIAL_PROTOCOLLNPGM("Done.");
|
|
}
|
|
|
|
//
|
|
// Store a Mesh in the EEPROM
|
|
//
|
|
|
|
if (parser.seen('S')) { // Store (or Save) Current Mesh Data
|
|
g29_storage_slot = parser.has_value() ? parser.value_int() : state.storage_slot;
|
|
|
|
if (g29_storage_slot == -1) { // Special case, we are going to 'Export' the mesh to the
|
|
SERIAL_ECHOLNPGM("G29 I 999"); // host in a form it can be reconstructed on a different machine
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
|
|
if (!isnan(z_values[x][y])) {
|
|
SERIAL_ECHOPAIR("M421 I ", x);
|
|
SERIAL_ECHOPAIR(" J ", y);
|
|
SERIAL_ECHOPGM(" Z ");
|
|
SERIAL_ECHO_F(z_values[x][y], 6);
|
|
SERIAL_ECHOPAIR(" ; X ", LOGICAL_X_POSITION(mesh_index_to_xpos(x)));
|
|
SERIAL_ECHOPAIR(", Y ", LOGICAL_Y_POSITION(mesh_index_to_ypos(y)));
|
|
SERIAL_EOL();
|
|
}
|
|
return;
|
|
}
|
|
|
|
int16_t a = settings.calc_num_meshes();
|
|
|
|
if (!a) {
|
|
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available.");
|
|
goto LEAVE;
|
|
}
|
|
|
|
if (!WITHIN(g29_storage_slot, 0, a - 1)) {
|
|
SERIAL_PROTOCOLLNPGM("?Invalid storage slot.");
|
|
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
|
|
goto LEAVE;
|
|
}
|
|
|
|
settings.store_mesh(g29_storage_slot);
|
|
state.storage_slot = g29_storage_slot;
|
|
|
|
SERIAL_PROTOCOLLNPGM("Done.");
|
|
}
|
|
|
|
if (parser.seen('T'))
|
|
display_map(parser.has_value() ? parser.value_int() : 0);
|
|
|
|
/**
|
|
* This code may not be needed... Prepare for its removal...
|
|
*
|
|
*/
|
|
#if 0
|
|
if (parser.seen('Z')) {
|
|
if (parser.has_value())
|
|
state.z_offset = parser.value_float(); // do the simple case. Just lock in the specified value
|
|
else {
|
|
save_ubl_active_state_and_disable();
|
|
//float measured_z = probe_pt(g29_x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, g29_y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
|
|
|
|
has_control_of_lcd_panel = true; // Grab the LCD Hardware
|
|
float measured_z = 1.5;
|
|
do_blocking_move_to_z(measured_z); // Get close to the bed, but leave some space so we don't damage anything
|
|
// The user is not going to be locking in a new Z-Offset very often so
|
|
// it won't be that painful to spin the Encoder Wheel for 1.5mm
|
|
lcd_refresh();
|
|
lcd_z_offset_edit_setup(measured_z);
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
|
|
do {
|
|
measured_z = lcd_z_offset_edit();
|
|
idle();
|
|
do_blocking_move_to_z(measured_z);
|
|
} while (!ubl_lcd_clicked());
|
|
|
|
has_control_of_lcd_panel = true; // There is a race condition for the encoder click.
|
|
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
|
|
// or here. So, until we are done looking for a long encoder press,
|
|
// we need to take control of the panel
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
lcd_return_to_status();
|
|
|
|
const millis_t nxt = millis() + 1500UL;
|
|
while (ubl_lcd_clicked()) { // debounce and watch for abort
|
|
idle();
|
|
if (ELAPSED(millis(), nxt)) {
|
|
SERIAL_PROTOCOLLNPGM("\nZ-Offset Adjustment Stopped.");
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
LCD_MESSAGEPGM(MSG_UBL_Z_OFFSET_STOPPED);
|
|
restore_ubl_active_state_and_leave();
|
|
goto LEAVE;
|
|
}
|
|
}
|
|
has_control_of_lcd_panel = false;
|
|
safe_delay(20); // We don't want any switch noise.
|
|
|
|
state.z_offset = measured_z;
|
|
|
|
lcd_refresh();
|
|
restore_ubl_active_state_and_leave();
|
|
}
|
|
}
|
|
#endif
|
|
|
|
LEAVE:
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
lcd_reset_alert_level();
|
|
LCD_MESSAGEPGM("");
|
|
lcd_quick_feedback();
|
|
|
|
has_control_of_lcd_panel = false;
|
|
#endif
|
|
|
|
return;
|
|
}
|
|
|
|
void unified_bed_leveling::find_mean_mesh_height() {
|
|
float sum = 0.0;
|
|
int n = 0;
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
|
|
if (!isnan(z_values[x][y])) {
|
|
sum += z_values[x][y];
|
|
n++;
|
|
}
|
|
|
|
const float mean = sum / n;
|
|
|
|
//
|
|
// Sum the squares of difference from mean
|
|
//
|
|
float sum_of_diff_squared = 0.0;
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
|
|
if (!isnan(z_values[x][y]))
|
|
sum_of_diff_squared += sq(z_values[x][y] - mean);
|
|
|
|
SERIAL_ECHOLNPAIR("# of samples: ", n);
|
|
SERIAL_ECHOPGM("Mean Mesh Height: ");
|
|
SERIAL_ECHO_F(mean, 6);
|
|
SERIAL_EOL();
|
|
|
|
const float sigma = sqrt(sum_of_diff_squared / (n + 1));
|
|
SERIAL_ECHOPGM("Standard Deviation: ");
|
|
SERIAL_ECHO_F(sigma, 6);
|
|
SERIAL_EOL();
|
|
|
|
if (g29_c_flag)
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
|
|
if (!isnan(z_values[x][y]))
|
|
z_values[x][y] -= mean + g29_constant;
|
|
}
|
|
|
|
void unified_bed_leveling::shift_mesh_height() {
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
|
|
if (!isnan(z_values[x][y]))
|
|
z_values[x][y] += g29_constant;
|
|
}
|
|
|
|
/**
|
|
* Probe all invalidated locations of the mesh that can be reached by the probe.
|
|
* This attempts to fill in locations closest to the nozzle's start location first.
|
|
*/
|
|
void unified_bed_leveling::probe_entire_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map, const bool stow_probe, bool close_or_far) {
|
|
mesh_index_pair location;
|
|
|
|
has_control_of_lcd_panel = true;
|
|
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
|
DEPLOY_PROBE();
|
|
|
|
uint16_t max_iterations = GRID_MAX_POINTS;
|
|
|
|
do {
|
|
#if ENABLED(NEWPANEL)
|
|
if (ubl_lcd_clicked()) {
|
|
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.\n");
|
|
lcd_quick_feedback();
|
|
STOW_PROBE();
|
|
while (ubl_lcd_clicked()) idle();
|
|
has_control_of_lcd_panel = false;
|
|
restore_ubl_active_state_and_leave();
|
|
safe_delay(50); // Debounce the Encoder wheel
|
|
return;
|
|
}
|
|
#endif
|
|
|
|
location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_PROBE_AS_REFERENCE, NULL, close_or_far);
|
|
|
|
if (location.x_index >= 0) { // mesh point found and is reachable by probe
|
|
const float rawx = mesh_index_to_xpos(location.x_index),
|
|
rawy = mesh_index_to_ypos(location.y_index);
|
|
|
|
const float measured_z = probe_pt(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy), stow_probe, g29_verbose_level); // TODO: Needs error handling
|
|
z_values[location.x_index][location.y_index] = measured_z;
|
|
}
|
|
|
|
if (do_ubl_mesh_map) display_map(g29_map_type);
|
|
|
|
} while (location.x_index >= 0 && --max_iterations);
|
|
|
|
STOW_PROBE();
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
do_blocking_move_to_xy(
|
|
constrain(lx - (X_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_X, UBL_MESH_MAX_X),
|
|
constrain(ly - (Y_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_Y, UBL_MESH_MAX_Y)
|
|
);
|
|
}
|
|
|
|
void unified_bed_leveling::tilt_mesh_based_on_3pts(const float &z1, const float &z2, const float &z3) {
|
|
matrix_3x3 rotation;
|
|
vector_3 v1 = vector_3( (UBL_PROBE_PT_1_X - UBL_PROBE_PT_2_X),
|
|
(UBL_PROBE_PT_1_Y - UBL_PROBE_PT_2_Y),
|
|
(z1 - z2) ),
|
|
|
|
v2 = vector_3( (UBL_PROBE_PT_3_X - UBL_PROBE_PT_2_X),
|
|
(UBL_PROBE_PT_3_Y - UBL_PROBE_PT_2_Y),
|
|
(z3 - z2) ),
|
|
|
|
normal = vector_3::cross(v1, v2);
|
|
|
|
normal = normal.get_normal();
|
|
|
|
/**
|
|
* This vector is normal to the tilted plane.
|
|
* However, we don't know its direction. We need it to point up. So if
|
|
* Z is negative, we need to invert the sign of all components of the vector
|
|
*/
|
|
if (normal.z < 0.0) {
|
|
normal.x = -normal.x;
|
|
normal.y = -normal.y;
|
|
normal.z = -normal.z;
|
|
}
|
|
|
|
rotation = matrix_3x3::create_look_at(vector_3(normal.x, normal.y, 1));
|
|
|
|
if (g29_verbose_level > 2) {
|
|
SERIAL_ECHOPGM("bed plane normal = [");
|
|
SERIAL_PROTOCOL_F(normal.x, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(normal.y, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(normal.z, 7);
|
|
SERIAL_ECHOLNPGM("]");
|
|
rotation.debug(PSTR("rotation matrix:"));
|
|
}
|
|
|
|
//
|
|
// All of 3 of these points should give us the same d constant
|
|
//
|
|
|
|
float t = normal.x * (UBL_PROBE_PT_1_X) + normal.y * (UBL_PROBE_PT_1_Y),
|
|
d = t + normal.z * z1;
|
|
|
|
if (g29_verbose_level>2) {
|
|
SERIAL_ECHOPGM("D constant: ");
|
|
SERIAL_PROTOCOL_F(d, 7);
|
|
SERIAL_ECHOLNPGM(" ");
|
|
}
|
|
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
SERIAL_ECHOPGM("d from 1st point: ");
|
|
SERIAL_ECHO_F(d, 6);
|
|
SERIAL_EOL();
|
|
t = normal.x * (UBL_PROBE_PT_2_X) + normal.y * (UBL_PROBE_PT_2_Y);
|
|
d = t + normal.z * z2;
|
|
SERIAL_ECHOPGM("d from 2nd point: ");
|
|
SERIAL_ECHO_F(d, 6);
|
|
SERIAL_EOL();
|
|
t = normal.x * (UBL_PROBE_PT_3_X) + normal.y * (UBL_PROBE_PT_3_Y);
|
|
d = t + normal.z * z3;
|
|
SERIAL_ECHOPGM("d from 3rd point: ");
|
|
SERIAL_ECHO_F(d, 6);
|
|
SERIAL_EOL();
|
|
}
|
|
#endif
|
|
|
|
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
|
|
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
|
|
float x_tmp = mesh_index_to_xpos(i),
|
|
y_tmp = mesh_index_to_ypos(j),
|
|
z_tmp = z_values[i][j];
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
SERIAL_ECHOPGM("before rotation = [");
|
|
SERIAL_PROTOCOL_F(x_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(y_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(z_tmp, 7);
|
|
SERIAL_ECHOPGM("] ---> ");
|
|
safe_delay(20);
|
|
}
|
|
#endif
|
|
apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp);
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
SERIAL_ECHOPGM("after rotation = [");
|
|
SERIAL_PROTOCOL_F(x_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(y_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(z_tmp, 7);
|
|
SERIAL_ECHOLNPGM("]");
|
|
safe_delay(55);
|
|
}
|
|
#endif
|
|
z_values[i][j] += z_tmp - d;
|
|
}
|
|
}
|
|
}
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
float unified_bed_leveling::measure_point_with_encoder() {
|
|
|
|
while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel
|
|
delay(50); // debounce
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
|
|
idle();
|
|
if (encoder_diff) {
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + 0.01 * float(encoder_diff));
|
|
encoder_diff = 0;
|
|
}
|
|
}
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
return current_position[Z_AXIS];
|
|
}
|
|
|
|
static void echo_and_take_a_measurement() { SERIAL_PROTOCOLLNPGM(" and take a measurement."); }
|
|
|
|
float unified_bed_leveling::measure_business_card_thickness(float &in_height) {
|
|
has_control_of_lcd_panel = true;
|
|
save_ubl_active_state_and_disable(); // Disable bed level correction for probing
|
|
|
|
do_blocking_move_to_z(in_height);
|
|
do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y)));
|
|
//, min(planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS]) / 2.0);
|
|
stepper.synchronize();
|
|
|
|
SERIAL_PROTOCOLPGM("Place shim under nozzle");
|
|
LCD_MESSAGEPGM(MSG_UBL_BC_INSERT);
|
|
lcd_return_to_status();
|
|
echo_and_take_a_measurement();
|
|
|
|
const float z1 = measure_point_with_encoder();
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
|
|
stepper.synchronize();
|
|
|
|
SERIAL_PROTOCOLPGM("Remove shim");
|
|
LCD_MESSAGEPGM(MSG_UBL_BC_REMOVE);
|
|
echo_and_take_a_measurement();
|
|
|
|
const float z2 = measure_point_with_encoder();
|
|
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + Z_CLEARANCE_BETWEEN_PROBES);
|
|
|
|
const float thickness = abs(z1 - z2);
|
|
|
|
if (g29_verbose_level > 1) {
|
|
SERIAL_PROTOCOLPGM("Business Card is ");
|
|
SERIAL_PROTOCOL_F(thickness, 4);
|
|
SERIAL_PROTOCOLLNPGM("mm thick.");
|
|
}
|
|
|
|
in_height = current_position[Z_AXIS]; // do manual probing at lower height
|
|
|
|
has_control_of_lcd_panel = false;
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
return thickness;
|
|
}
|
|
|
|
void unified_bed_leveling::manually_probe_remaining_mesh(const float &lx, const float &ly, const float &z_clearance, const float &thick, const bool do_ubl_mesh_map) {
|
|
|
|
has_control_of_lcd_panel = true;
|
|
|
|
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
do_blocking_move_to_xy(lx, ly);
|
|
|
|
lcd_return_to_status();
|
|
|
|
mesh_index_pair location;
|
|
do {
|
|
location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_NOZZLE_AS_REFERENCE, NULL, false);
|
|
// It doesn't matter if the probe can't reach the NAN location. This is a manual probe.
|
|
if (location.x_index < 0 && location.y_index < 0) continue;
|
|
|
|
const float rawx = mesh_index_to_xpos(location.x_index),
|
|
rawy = mesh_index_to_ypos(location.y_index),
|
|
xProbe = LOGICAL_X_POSITION(rawx),
|
|
yProbe = LOGICAL_Y_POSITION(rawy);
|
|
|
|
if (!position_is_reachable_raw_xy(rawx, rawy)) break; // SHOULD NOT OCCUR (find_closest_mesh_point only returns reachable points)
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
|
|
LCD_MESSAGEPGM(MSG_UBL_MOVING_TO_NEXT);
|
|
|
|
do_blocking_move_to_xy(xProbe, yProbe);
|
|
do_blocking_move_to_z(z_clearance);
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
has_control_of_lcd_panel = true;
|
|
|
|
if (do_ubl_mesh_map) display_map(g29_map_type); // show user where we're probing
|
|
|
|
serialprintPGM(parser.seen('B') ? PSTR(MSG_UBL_BC_INSERT) : PSTR(MSG_UBL_BC_INSERT2));
|
|
|
|
const float z_step = 0.01; // existing behavior: 0.01mm per click, occasionally step
|
|
//const float z_step = 1.0 / planner.axis_steps_per_mm[Z_AXIS]; // approx one step each click
|
|
|
|
while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel
|
|
delay(50); // debounce
|
|
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
|
|
idle();
|
|
if (encoder_diff) {
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + float(encoder_diff) * z_step);
|
|
encoder_diff = 0;
|
|
}
|
|
}
|
|
|
|
// this sequence to detect an ubl_lcd_clicked() debounce it and leave if it is
|
|
// a Press and Hold is repeated in a lot of places (including G26_Mesh_Validation.cpp). This
|
|
// should be redone and compressed.
|
|
const millis_t nxt = millis() + 1500L;
|
|
while (ubl_lcd_clicked()) { // debounce and watch for abort
|
|
idle();
|
|
if (ELAPSED(millis(), nxt)) {
|
|
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.");
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
lcd_quick_feedback();
|
|
while (ubl_lcd_clicked()) idle();
|
|
has_control_of_lcd_panel = false;
|
|
#endif
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
restore_ubl_active_state_and_leave();
|
|
return;
|
|
}
|
|
}
|
|
|
|
z_values[location.x_index][location.y_index] = current_position[Z_AXIS] - thick;
|
|
if (g29_verbose_level > 2) {
|
|
SERIAL_PROTOCOLPGM("Mesh Point Measured at: ");
|
|
SERIAL_PROTOCOL_F(z_values[location.x_index][location.y_index], 6);
|
|
SERIAL_EOL();
|
|
}
|
|
} while (location.x_index >= 0 && location.y_index >= 0);
|
|
|
|
if (do_ubl_mesh_map) display_map(g29_map_type);
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
do_blocking_move_to_xy(lx, ly);
|
|
}
|
|
#endif
|
|
|
|
bool unified_bed_leveling::g29_parameter_parsing() {
|
|
bool err_flag = false;
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
LCD_MESSAGEPGM(MSG_UBL_DOING_G29);
|
|
lcd_quick_feedback();
|
|
#endif
|
|
|
|
g29_constant = 0.0;
|
|
g29_repetition_cnt = 0;
|
|
|
|
g29_x_flag = parser.seen('X') && parser.has_value();
|
|
g29_x_pos = g29_x_flag ? parser.value_float() : current_position[X_AXIS];
|
|
g29_y_flag = parser.seen('Y') && parser.has_value();
|
|
g29_y_pos = g29_y_flag ? parser.value_float() : current_position[Y_AXIS];
|
|
|
|
if (parser.seen('R')) {
|
|
g29_repetition_cnt = parser.has_value() ? parser.value_int() : GRID_MAX_POINTS;
|
|
NOMORE(g29_repetition_cnt, GRID_MAX_POINTS);
|
|
if (g29_repetition_cnt < 1) {
|
|
SERIAL_PROTOCOLLNPGM("?(R)epetition count invalid (1+).\n");
|
|
return UBL_ERR;
|
|
}
|
|
}
|
|
|
|
g29_verbose_level = parser.seen('V') ? parser.value_int() : 0;
|
|
if (!WITHIN(g29_verbose_level, 0, 4)) {
|
|
SERIAL_PROTOCOLLNPGM("?(V)erbose level is implausible (0-4).\n");
|
|
err_flag = true;
|
|
}
|
|
|
|
if (parser.seen('P')) {
|
|
g29_phase_value = parser.value_int();
|
|
if (!WITHIN(g29_phase_value, 0, 6)) {
|
|
SERIAL_PROTOCOLLNPGM("?(P)hase value invalid (0-6).\n");
|
|
err_flag = true;
|
|
}
|
|
}
|
|
|
|
if (parser.seen('J')) {
|
|
g29_grid_size = parser.has_value() ? parser.value_int() : 0;
|
|
if (g29_grid_size && !WITHIN(g29_grid_size, 2, 9)) {
|
|
SERIAL_PROTOCOLLNPGM("?Invalid grid size (J) specified (2-9).\n");
|
|
err_flag = true;
|
|
}
|
|
}
|
|
|
|
if (g29_x_flag != g29_y_flag) {
|
|
SERIAL_PROTOCOLLNPGM("Both X & Y locations must be specified.\n");
|
|
err_flag = true;
|
|
}
|
|
if (!WITHIN(RAW_X_POSITION(g29_x_pos), X_MIN_POS, X_MAX_POS)) {
|
|
SERIAL_PROTOCOLLNPGM("Invalid X location specified.\n");
|
|
err_flag = true;
|
|
}
|
|
|
|
if (!WITHIN(RAW_Y_POSITION(g29_y_pos), Y_MIN_POS, Y_MAX_POS)) {
|
|
SERIAL_PROTOCOLLNPGM("Invalid Y location specified.\n");
|
|
err_flag = true;
|
|
}
|
|
|
|
if (err_flag) return UBL_ERR;
|
|
|
|
/**
|
|
* Activate or deactivate UBL
|
|
* Note: UBL's G29 restores the state set here when done.
|
|
* Leveling is being enabled here with old data, possibly
|
|
* none. Error handling should disable for safety...
|
|
*/
|
|
if (parser.seen('A')) {
|
|
if (parser.seen('D')) {
|
|
SERIAL_PROTOCOLLNPGM("?Can't activate and deactivate at the same time.\n");
|
|
return UBL_ERR;
|
|
}
|
|
set_bed_leveling_enabled(true);
|
|
report_state();
|
|
}
|
|
else if (parser.seen('D')) {
|
|
set_bed_leveling_enabled(false);
|
|
report_state();
|
|
}
|
|
|
|
// Set global 'C' flag and its value
|
|
if ((g29_c_flag = parser.seen('C')))
|
|
g29_constant = parser.value_float();
|
|
|
|
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
|
if (parser.seen('F') && parser.has_value()) {
|
|
const float fh = parser.value_float();
|
|
if (!WITHIN(fh, 0.0, 100.0)) {
|
|
SERIAL_PROTOCOLLNPGM("?(F)ade height for Bed Level Correction not plausible.\n");
|
|
return UBL_ERR;
|
|
}
|
|
set_z_fade_height(fh);
|
|
}
|
|
#endif
|
|
|
|
g29_map_type = parser.seen('T') && parser.has_value() ? parser.value_int() : 0;
|
|
if (!WITHIN(g29_map_type, 0, 2)) {
|
|
SERIAL_PROTOCOLLNPGM("Invalid map type.\n");
|
|
return UBL_ERR;
|
|
}
|
|
return UBL_OK;
|
|
}
|
|
|
|
static int ubl_state_at_invocation = 0,
|
|
ubl_state_recursion_chk = 0;
|
|
|
|
void unified_bed_leveling::save_ubl_active_state_and_disable() {
|
|
ubl_state_recursion_chk++;
|
|
if (ubl_state_recursion_chk != 1) {
|
|
SERIAL_ECHOLNPGM("save_ubl_active_state_and_disabled() called multiple times in a row.");
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
LCD_MESSAGEPGM(MSG_UBL_SAVE_ERROR);
|
|
lcd_quick_feedback();
|
|
#endif
|
|
|
|
return;
|
|
}
|
|
ubl_state_at_invocation = state.active;
|
|
set_bed_leveling_enabled(false);
|
|
}
|
|
|
|
void unified_bed_leveling::restore_ubl_active_state_and_leave() {
|
|
if (--ubl_state_recursion_chk) {
|
|
SERIAL_ECHOLNPGM("restore_ubl_active_state_and_leave() called too many times.");
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
LCD_MESSAGEPGM(MSG_UBL_RESTORE_ERROR);
|
|
lcd_quick_feedback();
|
|
#endif
|
|
|
|
return;
|
|
}
|
|
set_bed_leveling_enabled(ubl_state_at_invocation);
|
|
}
|
|
|
|
/**
|
|
* Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
|
|
* good to have the extra information. Soon... we prune this to just a few items
|
|
*/
|
|
void unified_bed_leveling::g29_what_command() {
|
|
report_state();
|
|
|
|
if (state.storage_slot == -1)
|
|
SERIAL_PROTOCOLPGM("No Mesh Loaded.");
|
|
else {
|
|
SERIAL_PROTOCOLPAIR("Mesh ", state.storage_slot);
|
|
SERIAL_PROTOCOLPGM(" Loaded.");
|
|
}
|
|
SERIAL_EOL();
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLLNPAIR("UBL object count: ", (int)ubl_cnt);
|
|
|
|
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
|
SERIAL_PROTOCOL("planner.z_fade_height : ");
|
|
SERIAL_PROTOCOL_F(planner.z_fade_height, 4);
|
|
SERIAL_EOL();
|
|
#endif
|
|
|
|
#if HAS_BED_PROBE
|
|
SERIAL_PROTOCOLPGM("zprobe_zoffset: ");
|
|
SERIAL_PROTOCOL_F(zprobe_zoffset, 7);
|
|
SERIAL_EOL();
|
|
#endif
|
|
|
|
SERIAL_ECHOLNPAIR("UBL_MESH_MIN_X " STRINGIFY(UBL_MESH_MIN_X) "=", UBL_MESH_MIN_X);
|
|
SERIAL_ECHOLNPAIR("UBL_MESH_MIN_Y " STRINGIFY(UBL_MESH_MIN_Y) "=", UBL_MESH_MIN_Y);
|
|
safe_delay(25);
|
|
SERIAL_ECHOLNPAIR("UBL_MESH_MAX_X " STRINGIFY(UBL_MESH_MAX_X) "=", UBL_MESH_MAX_X);
|
|
SERIAL_ECHOLNPAIR("UBL_MESH_MAX_Y " STRINGIFY(UBL_MESH_MAX_Y) "=", UBL_MESH_MAX_Y);
|
|
safe_delay(25);
|
|
SERIAL_ECHOLNPAIR("GRID_MAX_POINTS_X ", GRID_MAX_POINTS_X);
|
|
SERIAL_ECHOLNPAIR("GRID_MAX_POINTS_Y ", GRID_MAX_POINTS_Y);
|
|
safe_delay(25);
|
|
SERIAL_ECHOLNPAIR("MESH_X_DIST ", MESH_X_DIST);
|
|
SERIAL_ECHOLNPAIR("MESH_Y_DIST ", MESH_Y_DIST);
|
|
safe_delay(25);
|
|
|
|
SERIAL_PROTOCOLPGM("X-Axis Mesh Points at: ");
|
|
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
|
|
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(mesh_index_to_xpos(i)), 3);
|
|
SERIAL_PROTOCOLPGM(" ");
|
|
safe_delay(25);
|
|
}
|
|
SERIAL_EOL();
|
|
|
|
SERIAL_PROTOCOLPGM("Y-Axis Mesh Points at: ");
|
|
for (uint8_t i = 0; i < GRID_MAX_POINTS_Y; i++) {
|
|
SERIAL_PROTOCOL_F(LOGICAL_Y_POSITION(mesh_index_to_ypos(i)), 3);
|
|
SERIAL_PROTOCOLPGM(" ");
|
|
safe_delay(25);
|
|
}
|
|
SERIAL_EOL();
|
|
|
|
#if HAS_KILL
|
|
SERIAL_PROTOCOLPAIR("Kill pin on :", KILL_PIN);
|
|
SERIAL_PROTOCOLLNPAIR(" state:", READ(KILL_PIN));
|
|
#endif
|
|
SERIAL_EOL();
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLLNPAIR("ubl_state_at_invocation :", ubl_state_at_invocation);
|
|
SERIAL_EOL();
|
|
SERIAL_PROTOCOLLNPAIR("ubl_state_recursion_chk :", ubl_state_recursion_chk);
|
|
SERIAL_EOL();
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLPAIR("Meshes go from ", hex_address((void*)settings.get_start_of_meshes()));
|
|
SERIAL_PROTOCOLLNPAIR(" to ", hex_address((void*)settings.get_end_of_meshes()));
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLLNPAIR("sizeof(ubl) : ", (int)sizeof(ubl));
|
|
SERIAL_EOL();
|
|
SERIAL_PROTOCOLLNPAIR("z_value[][] size: ", (int)sizeof(z_values));
|
|
SERIAL_EOL();
|
|
safe_delay(25);
|
|
|
|
SERIAL_PROTOCOLLNPAIR("EEPROM free for UBL: ", hex_address((void*)(settings.get_end_of_meshes() - settings.get_start_of_meshes())));
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLPAIR("EEPROM can hold ", settings.calc_num_meshes());
|
|
SERIAL_PROTOCOLLNPGM(" meshes.\n");
|
|
safe_delay(25);
|
|
|
|
if (!sanity_check()) {
|
|
echo_name();
|
|
SERIAL_PROTOCOLLNPGM(" sanity checks passed.");
|
|
}
|
|
}
|
|
|
|
/**
|
|
* When we are fully debugged, the EEPROM dump command will get deleted also. But
|
|
* right now, it is good to have the extra information. Soon... we prune this.
|
|
*/
|
|
void unified_bed_leveling::g29_eeprom_dump() {
|
|
unsigned char cccc;
|
|
uint16_t kkkk;
|
|
|
|
SERIAL_ECHO_START();
|
|
SERIAL_ECHOLNPGM("EEPROM Dump:");
|
|
for (uint16_t i = 0; i < E2END + 1; i += 16) {
|
|
if (!(i & 0x3)) idle();
|
|
print_hex_word(i);
|
|
SERIAL_ECHOPGM(": ");
|
|
for (uint16_t j = 0; j < 16; j++) {
|
|
kkkk = i + j;
|
|
eeprom_read_block(&cccc, (void *)kkkk, 1);
|
|
print_hex_byte(cccc);
|
|
SERIAL_ECHO(' ');
|
|
}
|
|
SERIAL_EOL();
|
|
}
|
|
SERIAL_EOL();
|
|
}
|
|
|
|
/**
|
|
* When we are fully debugged, this may go away. But there are some valid
|
|
* use cases for the users. So we can wait and see what to do with it.
|
|
*/
|
|
void unified_bed_leveling::g29_compare_current_mesh_to_stored_mesh() {
|
|
int16_t a = settings.calc_num_meshes();
|
|
|
|
if (!a) {
|
|
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available.");
|
|
return;
|
|
}
|
|
|
|
if (!parser.has_value()) {
|
|
SERIAL_PROTOCOLLNPGM("?Storage slot # required.");
|
|
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
|
|
return;
|
|
}
|
|
|
|
g29_storage_slot = parser.value_int();
|
|
|
|
if (!WITHIN(g29_storage_slot, 0, a - 1)) {
|
|
SERIAL_PROTOCOLLNPGM("?Invalid storage slot.");
|
|
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1);
|
|
return;
|
|
}
|
|
|
|
float tmp_z_values[GRID_MAX_POINTS_X][GRID_MAX_POINTS_Y];
|
|
settings.load_mesh(g29_storage_slot, &tmp_z_values);
|
|
|
|
SERIAL_PROTOCOLPAIR("Subtracting mesh in slot ", g29_storage_slot);
|
|
SERIAL_PROTOCOLLNPGM(" from current mesh.");
|
|
|
|
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
|
|
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
|
|
z_values[x][y] -= tmp_z_values[x][y];
|
|
}
|
|
|
|
mesh_index_pair unified_bed_leveling::find_closest_mesh_point_of_type(const MeshPointType type, const float &lx, const float &ly, const bool probe_as_reference, unsigned int bits[16], const bool far_flag) {
|
|
mesh_index_pair out_mesh;
|
|
out_mesh.x_index = out_mesh.y_index = -1;
|
|
|
|
// Get our reference position. Either the nozzle or probe location.
|
|
const float px = RAW_X_POSITION(lx) - (probe_as_reference == USE_PROBE_AS_REFERENCE ? X_PROBE_OFFSET_FROM_EXTRUDER : 0),
|
|
py = RAW_Y_POSITION(ly) - (probe_as_reference == USE_PROBE_AS_REFERENCE ? Y_PROBE_OFFSET_FROM_EXTRUDER : 0);
|
|
|
|
float best_so_far = far_flag ? -99999.99 : 99999.99;
|
|
|
|
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
|
|
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
|
|
|
|
if ( (type == INVALID && isnan(z_values[i][j])) // Check to see if this location holds the right thing
|
|
|| (type == REAL && !isnan(z_values[i][j]))
|
|
|| (type == SET_IN_BITMAP && is_bit_set(bits, i, j))
|
|
) {
|
|
// We only get here if we found a Mesh Point of the specified type
|
|
|
|
float raw_x = RAW_CURRENT_POSITION(X), raw_y = RAW_CURRENT_POSITION(Y);
|
|
const float mx = mesh_index_to_xpos(i),
|
|
my = mesh_index_to_ypos(j);
|
|
|
|
// If using the probe as the reference there are some unreachable locations.
|
|
// Also for round beds, there are grid points outside the bed the nozzle can't reach.
|
|
// Prune them from the list and ignore them till the next Phase (manual nozzle probing).
|
|
|
|
if (probe_as_reference ? !position_is_reachable_by_probe_raw_xy(mx, my) : !position_is_reachable_raw_xy(mx, my))
|
|
continue;
|
|
|
|
// Reachable. Check if it's the best_so_far location to the nozzle.
|
|
// Add in a weighting factor that considers the current location of the nozzle.
|
|
|
|
float distance = HYPOT(px - mx, py - my);
|
|
|
|
/**
|
|
* If doing the far_flag action, we want to be as far as possible
|
|
* from the starting point and from any other probed points. We
|
|
* want the next point spread out and filling in any blank spaces
|
|
* in the mesh. So we add in some of the distance to every probed
|
|
* point we can find.
|
|
*/
|
|
if (far_flag) {
|
|
for (uint8_t k = 0; k < GRID_MAX_POINTS_X; k++) {
|
|
for (uint8_t l = 0; l < GRID_MAX_POINTS_Y; l++) {
|
|
if (i != k && j != l && !isnan(z_values[k][l])) {
|
|
//distance += pow((float) abs(i - k) * (MESH_X_DIST), 2) + pow((float) abs(j - l) * (MESH_Y_DIST), 2); // working here
|
|
distance += HYPOT(MESH_X_DIST, MESH_Y_DIST) / log(HYPOT((i - k) * (MESH_X_DIST) + .001, (j - l) * (MESH_Y_DIST)) + .001);
|
|
}
|
|
}
|
|
}
|
|
}
|
|
else
|
|
// factor in the distance from the current location for the normal case
|
|
// so the nozzle isn't running all over the bed.
|
|
distance += HYPOT(raw_x - mx, raw_y - my) * 0.1;
|
|
|
|
// if far_flag, look for farthest point
|
|
if (far_flag == (distance > best_so_far) && distance != best_so_far) {
|
|
best_so_far = distance; // We found a closer/farther location with
|
|
out_mesh.x_index = i; // the specified type of mesh value.
|
|
out_mesh.y_index = j;
|
|
out_mesh.distance = best_so_far;
|
|
}
|
|
}
|
|
} // for j
|
|
} // for i
|
|
|
|
return out_mesh;
|
|
}
|
|
|
|
#if ENABLED(NEWPANEL)
|
|
void unified_bed_leveling::fine_tune_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map) {
|
|
if (!parser.seen('R')) // fine_tune_mesh() is special. If no repetition count flag is specified
|
|
g29_repetition_cnt = 1; // do exactly one mesh location. Otherwise use what the parser decided.
|
|
|
|
mesh_index_pair location;
|
|
uint16_t not_done[16];
|
|
|
|
if (!position_is_reachable_xy(lx, ly)) {
|
|
SERIAL_PROTOCOLLNPGM("(X,Y) outside printable radius.");
|
|
return;
|
|
}
|
|
|
|
save_ubl_active_state_and_disable();
|
|
|
|
memset(not_done, 0xFF, sizeof(not_done));
|
|
|
|
LCD_MESSAGEPGM(MSG_UBL_FINE_TUNE_MESH);
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
do_blocking_move_to_xy(lx, ly);
|
|
do {
|
|
location = find_closest_mesh_point_of_type(SET_IN_BITMAP, lx, ly, USE_NOZZLE_AS_REFERENCE, not_done, false);
|
|
|
|
if (location.x_index < 0) break; // stop when we can't find any more reachable points.
|
|
|
|
bit_clear(not_done, location.x_index, location.y_index); // Mark this location as 'adjusted' so we will find a
|
|
// different location the next time through the loop
|
|
|
|
const float rawx = mesh_index_to_xpos(location.x_index),
|
|
rawy = mesh_index_to_ypos(location.y_index);
|
|
|
|
if (!position_is_reachable_raw_xy(rawx, rawy)) // SHOULD NOT OCCUR because find_closest_mesh_point_of_type will only return reachable
|
|
break;
|
|
|
|
float new_z = z_values[location.x_index][location.y_index];
|
|
|
|
if (isnan(new_z)) // if the mesh point is invalid, set it to 0.0 so it can be edited
|
|
new_z = 0.0;
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); // Move the nozzle to where we are going to edit
|
|
do_blocking_move_to_xy(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy));
|
|
|
|
new_z = floor(new_z * 1000.0) * 0.001; // Chop off digits after the 1000ths place
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
has_control_of_lcd_panel = true;
|
|
|
|
if (do_ubl_mesh_map) display_map(g29_map_type); // show the user which point is being adjusted
|
|
|
|
lcd_refresh();
|
|
|
|
lcd_mesh_edit_setup(new_z);
|
|
|
|
do {
|
|
new_z = lcd_mesh_edit();
|
|
#ifdef UBL_MESH_EDIT_MOVES_Z
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES + new_z); // Move the nozzle as the point is edited
|
|
#endif
|
|
idle();
|
|
} while (!ubl_lcd_clicked());
|
|
|
|
lcd_return_to_status();
|
|
|
|
// The technique used here generates a race condition for the encoder click.
|
|
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune) or here.
|
|
// Let's work on specifying a proper API for the LCD ASAP, OK?
|
|
has_control_of_lcd_panel = true;
|
|
|
|
// this sequence to detect an ubl_lcd_clicked() debounce it and leave if it is
|
|
// a Press and Hold is repeated in a lot of places (including G26_Mesh_Validation.cpp). This
|
|
// should be redone and compressed.
|
|
const millis_t nxt = millis() + 1500UL;
|
|
while (ubl_lcd_clicked()) { // debounce and watch for abort
|
|
idle();
|
|
if (ELAPSED(millis(), nxt)) {
|
|
ubl_lcd_map_control = false;
|
|
lcd_return_to_status();
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
LCD_MESSAGEPGM(MSG_EDITING_STOPPED);
|
|
|
|
while (ubl_lcd_clicked()) idle();
|
|
|
|
goto FINE_TUNE_EXIT;
|
|
}
|
|
}
|
|
|
|
safe_delay(20); // We don't want any switch noise.
|
|
|
|
z_values[location.x_index][location.y_index] = new_z;
|
|
|
|
lcd_refresh();
|
|
|
|
} while (location.x_index >= 0 && --g29_repetition_cnt > 0);
|
|
|
|
FINE_TUNE_EXIT:
|
|
|
|
has_control_of_lcd_panel = false;
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
if (do_ubl_mesh_map) display_map(g29_map_type);
|
|
restore_ubl_active_state_and_leave();
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
|
|
do_blocking_move_to_xy(lx, ly);
|
|
|
|
LCD_MESSAGEPGM(MSG_UBL_DONE_EDITING_MESH);
|
|
SERIAL_ECHOLNPGM("Done Editing Mesh");
|
|
|
|
if (ubl_lcd_map_control) {
|
|
#ifdef DOGLCD
|
|
lcd_goto_screen(_lcd_ubl_output_map_lcd);
|
|
#endif
|
|
}
|
|
else lcd_return_to_status();
|
|
}
|
|
#endif
|
|
|
|
/**
|
|
* 'Smart Fill': Scan from the outward edges of the mesh towards the center.
|
|
* If an invalid location is found, use the next two points (if valid) to
|
|
* calculate a 'reasonable' value for the unprobed mesh point.
|
|
*/
|
|
|
|
bool unified_bed_leveling::smart_fill_one(const uint8_t x, const uint8_t y, const int8_t xdir, const int8_t ydir) {
|
|
const int8_t x1 = x + xdir, x2 = x1 + xdir,
|
|
y1 = y + ydir, y2 = y1 + ydir;
|
|
// A NAN next to a pair of real values?
|
|
if (isnan(z_values[x][y]) && !isnan(z_values[x1][y1]) && !isnan(z_values[x2][y2])) {
|
|
if (z_values[x1][y1] < z_values[x2][y2]) // Angled downward?
|
|
z_values[x][y] = z_values[x1][y1]; // Use nearest (maybe a little too high.)
|
|
else
|
|
z_values[x][y] = 2.0 * z_values[x1][y1] - z_values[x2][y2]; // Angled upward...
|
|
return true;
|
|
}
|
|
return false;
|
|
}
|
|
|
|
typedef struct { uint8_t sx, ex, sy, ey; bool yfirst; } smart_fill_info;
|
|
|
|
void unified_bed_leveling::smart_fill_mesh() {
|
|
static const smart_fill_info
|
|
info0 PROGMEM = { 0, GRID_MAX_POINTS_X, 0, GRID_MAX_POINTS_Y - 2, false }, // Bottom of the mesh looking up
|
|
info1 PROGMEM = { 0, GRID_MAX_POINTS_X, GRID_MAX_POINTS_Y - 1, 0, false }, // Top of the mesh looking down
|
|
info2 PROGMEM = { 0, GRID_MAX_POINTS_X - 2, 0, GRID_MAX_POINTS_Y, true }, // Left side of the mesh looking right
|
|
info3 PROGMEM = { GRID_MAX_POINTS_X - 1, 0, 0, GRID_MAX_POINTS_Y, true }; // Right side of the mesh looking left
|
|
static const smart_fill_info * const info[] PROGMEM = { &info0, &info1, &info2, &info3 };
|
|
|
|
// static const smart_fill_info info[] PROGMEM = {
|
|
// { 0, GRID_MAX_POINTS_X, 0, GRID_MAX_POINTS_Y - 2, false } PROGMEM, // Bottom of the mesh looking up
|
|
// { 0, GRID_MAX_POINTS_X, GRID_MAX_POINTS_Y - 1, 0, false } PROGMEM, // Top of the mesh looking down
|
|
// { 0, GRID_MAX_POINTS_X - 2, 0, GRID_MAX_POINTS_Y, true } PROGMEM, // Left side of the mesh looking right
|
|
// { GRID_MAX_POINTS_X - 1, 0, 0, GRID_MAX_POINTS_Y, true } PROGMEM // Right side of the mesh looking left
|
|
// };
|
|
for (uint8_t i = 0; i < COUNT(info); ++i) {
|
|
const smart_fill_info *f = (smart_fill_info*)pgm_read_word(&info[i]);
|
|
const int8_t sx = pgm_read_word(&f->sx), sy = pgm_read_word(&f->sy),
|
|
ex = pgm_read_word(&f->ex), ey = pgm_read_word(&f->ey);
|
|
if (pgm_read_byte(&f->yfirst)) {
|
|
const int8_t dir = ex > sx ? 1 : -1;
|
|
for (uint8_t y = sy; y != ey; ++y)
|
|
for (uint8_t x = sx; x != ex; x += dir)
|
|
if (smart_fill_one(x, y, dir, 0)) break;
|
|
}
|
|
else {
|
|
const int8_t dir = ey > sy ? 1 : -1;
|
|
for (uint8_t x = sx; x != ex; ++x)
|
|
for (uint8_t y = sy; y != ey; y += dir)
|
|
if (smart_fill_one(x, y, 0, dir)) break;
|
|
}
|
|
}
|
|
}
|
|
|
|
void unified_bed_leveling::tilt_mesh_based_on_probed_grid(const bool do_ubl_mesh_map) {
|
|
constexpr int16_t x_min = max(MIN_PROBE_X, UBL_MESH_MIN_X),
|
|
x_max = min(MAX_PROBE_X, UBL_MESH_MAX_X),
|
|
y_min = max(MIN_PROBE_Y, UBL_MESH_MIN_Y),
|
|
y_max = min(MAX_PROBE_Y, UBL_MESH_MAX_Y);
|
|
|
|
const float dx = float(x_max - x_min) / (g29_grid_size - 1.0),
|
|
dy = float(y_max - y_min) / (g29_grid_size - 1.0);
|
|
|
|
struct linear_fit_data lsf_results;
|
|
incremental_LSF_reset(&lsf_results);
|
|
|
|
bool zig_zag = false;
|
|
for (uint8_t ix = 0; ix < g29_grid_size; ix++) {
|
|
const float x = float(x_min) + ix * dx;
|
|
for (int8_t iy = 0; iy < g29_grid_size; iy++) {
|
|
const float y = float(y_min) + dy * (zig_zag ? g29_grid_size - 1 - iy : iy);
|
|
float measured_z = probe_pt(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y), parser.seen('E'), g29_verbose_level); // TODO: Needs error handling
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
SERIAL_CHAR('(');
|
|
SERIAL_PROTOCOL_F(x, 7);
|
|
SERIAL_CHAR(',');
|
|
SERIAL_PROTOCOL_F(y, 7);
|
|
SERIAL_ECHOPGM(") logical: ");
|
|
SERIAL_CHAR('(');
|
|
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(x), 7);
|
|
SERIAL_CHAR(',');
|
|
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(y), 7);
|
|
SERIAL_ECHOPGM(") measured: ");
|
|
SERIAL_PROTOCOL_F(measured_z, 7);
|
|
SERIAL_ECHOPGM(" correction: ");
|
|
SERIAL_PROTOCOL_F(get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)), 7);
|
|
}
|
|
#endif
|
|
|
|
measured_z -= get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)) /* + zprobe_zoffset */ ;
|
|
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
SERIAL_ECHOPGM(" final >>>---> ");
|
|
SERIAL_PROTOCOL_F(measured_z, 7);
|
|
SERIAL_EOL();
|
|
}
|
|
#endif
|
|
|
|
incremental_LSF(&lsf_results, x, y, measured_z);
|
|
}
|
|
|
|
zig_zag ^= true;
|
|
}
|
|
|
|
if (finish_incremental_LSF(&lsf_results)) {
|
|
SERIAL_ECHOPGM("Could not complete LSF!");
|
|
return;
|
|
}
|
|
|
|
if (g29_verbose_level > 3) {
|
|
SERIAL_ECHOPGM("LSF Results A=");
|
|
SERIAL_PROTOCOL_F(lsf_results.A, 7);
|
|
SERIAL_ECHOPGM(" B=");
|
|
SERIAL_PROTOCOL_F(lsf_results.B, 7);
|
|
SERIAL_ECHOPGM(" D=");
|
|
SERIAL_PROTOCOL_F(lsf_results.D, 7);
|
|
SERIAL_EOL();
|
|
}
|
|
|
|
vector_3 normal = vector_3(lsf_results.A, lsf_results.B, 1.0000).get_normal();
|
|
|
|
if (g29_verbose_level > 2) {
|
|
SERIAL_ECHOPGM("bed plane normal = [");
|
|
SERIAL_PROTOCOL_F(normal.x, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(normal.y, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(normal.z, 7);
|
|
SERIAL_ECHOLNPGM("]");
|
|
}
|
|
|
|
matrix_3x3 rotation = matrix_3x3::create_look_at(vector_3(lsf_results.A, lsf_results.B, 1));
|
|
|
|
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
|
|
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
|
|
float x_tmp = mesh_index_to_xpos(i),
|
|
y_tmp = mesh_index_to_ypos(j),
|
|
z_tmp = z_values[i][j];
|
|
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
SERIAL_ECHOPGM("before rotation = [");
|
|
SERIAL_PROTOCOL_F(x_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(y_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(z_tmp, 7);
|
|
SERIAL_ECHOPGM("] ---> ");
|
|
safe_delay(20);
|
|
}
|
|
#endif
|
|
|
|
apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp);
|
|
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
SERIAL_ECHOPGM("after rotation = [");
|
|
SERIAL_PROTOCOL_F(x_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(y_tmp, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(z_tmp, 7);
|
|
SERIAL_ECHOLNPGM("]");
|
|
safe_delay(55);
|
|
}
|
|
#endif
|
|
|
|
z_values[i][j] += z_tmp - lsf_results.D;
|
|
}
|
|
}
|
|
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
if (DEBUGGING(LEVELING)) {
|
|
rotation.debug(PSTR("rotation matrix:"));
|
|
SERIAL_ECHOPGM("LSF Results A=");
|
|
SERIAL_PROTOCOL_F(lsf_results.A, 7);
|
|
SERIAL_ECHOPGM(" B=");
|
|
SERIAL_PROTOCOL_F(lsf_results.B, 7);
|
|
SERIAL_ECHOPGM(" D=");
|
|
SERIAL_PROTOCOL_F(lsf_results.D, 7);
|
|
SERIAL_EOL();
|
|
safe_delay(55);
|
|
|
|
SERIAL_ECHOPGM("bed plane normal = [");
|
|
SERIAL_PROTOCOL_F(normal.x, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(normal.y, 7);
|
|
SERIAL_PROTOCOLCHAR(',');
|
|
SERIAL_PROTOCOL_F(normal.z, 7);
|
|
SERIAL_ECHOPGM("]\n");
|
|
SERIAL_EOL();
|
|
}
|
|
#endif
|
|
|
|
if (do_ubl_mesh_map) display_map(g29_map_type);
|
|
}
|
|
|
|
#if ENABLED(UBL_G29_P31)
|
|
void unified_bed_leveling::smart_fill_wlsf(const float &weight_factor) {
|
|
|
|
// For each undefined mesh point, compute a distance-weighted least squares fit
|
|
// from all the originally populated mesh points, weighted toward the point
|
|
// being extrapolated so that nearby points will have greater influence on
|
|
// the point being extrapolated. Then extrapolate the mesh point from WLSF.
|
|
|
|
static_assert(GRID_MAX_POINTS_Y <= 16, "GRID_MAX_POINTS_Y too big");
|
|
uint16_t bitmap[GRID_MAX_POINTS_X] = { 0 };
|
|
struct linear_fit_data lsf_results;
|
|
|
|
SERIAL_ECHOPGM("Extrapolating mesh...");
|
|
|
|
const float weight_scaled = weight_factor * max(MESH_X_DIST, MESH_Y_DIST);
|
|
|
|
for (uint8_t jx = 0; jx < GRID_MAX_POINTS_X; jx++)
|
|
for (uint8_t jy = 0; jy < GRID_MAX_POINTS_Y; jy++)
|
|
if (!isnan(z_values[jx][jy]))
|
|
SBI(bitmap[jx], jy);
|
|
|
|
for (uint8_t ix = 0; ix < GRID_MAX_POINTS_X; ix++) {
|
|
const float px = mesh_index_to_xpos(ix);
|
|
for (uint8_t iy = 0; iy < GRID_MAX_POINTS_Y; iy++) {
|
|
const float py = mesh_index_to_ypos(iy);
|
|
if (isnan(z_values[ix][iy])) {
|
|
// undefined mesh point at (px,py), compute weighted LSF from original valid mesh points.
|
|
incremental_LSF_reset(&lsf_results);
|
|
for (uint8_t jx = 0; jx < GRID_MAX_POINTS_X; jx++) {
|
|
const float rx = mesh_index_to_xpos(jx);
|
|
for (uint8_t jy = 0; jy < GRID_MAX_POINTS_Y; jy++) {
|
|
if (TEST(bitmap[jx], jy)) {
|
|
const float ry = mesh_index_to_ypos(jy),
|
|
rz = z_values[jx][jy],
|
|
w = 1.0 + weight_scaled / HYPOT((rx - px), (ry - py));
|
|
incremental_WLSF(&lsf_results, rx, ry, rz, w);
|
|
}
|
|
}
|
|
}
|
|
if (finish_incremental_LSF(&lsf_results)) {
|
|
SERIAL_ECHOLNPGM("Insufficient data");
|
|
return;
|
|
}
|
|
const float ez = -lsf_results.D - lsf_results.A * px - lsf_results.B * py;
|
|
z_values[ix][iy] = ez;
|
|
idle(); // housekeeping
|
|
}
|
|
}
|
|
}
|
|
|
|
SERIAL_ECHOLNPGM("done");
|
|
}
|
|
#endif // UBL_G29_P31
|
|
|
|
#endif // AUTO_BED_LEVELING_UBL
|