wizard: Rewrite the fw upgrade check logic
- Handle the conversion from the V1 calibration status to the V2 bitmap for all past FW versions. - Allow to run the wizard in "Restore" mode (for example during upgrade or service prep) to complete any missing steps. - Fix service prep to use the above feature by clearing the appropriate calibration bits. - Remove exceptions for FW 3.2.0.4 which can now be handled cleanly.
This commit is contained in:
parent
d478aa5c5e
commit
16033b40b4
@ -1539,45 +1539,51 @@ void setup()
|
||||
lcd_show_fullscreen_message_and_wait_P(_i("Old settings found. Default PID, Esteps etc. will be set.")); //if EEPROM version or printer type was changed, inform user that default setting were loaded////MSG_DEFAULT_SETTINGS_LOADED c=20 r=6
|
||||
Config_StoreSettings();
|
||||
}
|
||||
if (eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE) >= 1) {
|
||||
lcd_wizard(WizState::Run);
|
||||
|
||||
// handle calibration status upgrade
|
||||
bool run_wizard = false;
|
||||
if (calibration_status_get(CALIBRATION_STATUS_UNKNOWN)) {
|
||||
CalibrationStatus calibration_status = 0;
|
||||
if (eeprom_read_byte((uint8_t*)EEPROM_CALIBRATION_STATUS_V1) == 1) {
|
||||
// calibrated printer upgraded from FW<3.12
|
||||
calibration_status |= (CALIBRATION_STATUS_SELFTEST | CALIBRATION_STATUS_XYZ | CALIBRATION_STATUS_Z | CALIBRATION_STATUS_LIVE_ADJUST);
|
||||
|
||||
if (eeprom_fw_version_older_than({3, 2, 0, 4})) {
|
||||
// printer upgraded from FW<3.2.0.4 and requires re-running selftest
|
||||
lcd_show_fullscreen_message_and_wait_P(_i("Selftest will be run to calibrate accurate sensorless rehoming."));////MSG_FORCE_SELFTEST c=20 r=8
|
||||
calibration_status &= ~CALIBRATION_STATUS_SELFTEST;
|
||||
run_wizard = true;
|
||||
}
|
||||
if (eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE) == 0) { //dont show calibration status messages if wizard is currently active
|
||||
if (calibration_status() == CALIBRATION_STATUS_ASSEMBLED ||
|
||||
calibration_status() == CALIBRATION_STATUS_UNKNOWN ||
|
||||
calibration_status() == CALIBRATION_STATUS_XYZ_CALIBRATION) {
|
||||
// Reset the babystepping values, so the printer will not move the Z axis up when the babystepping is enabled.
|
||||
eeprom_update_word(reinterpret_cast<uint16_t *>(&(EEPROM_Sheets_base->s[(eeprom_read_byte(&(EEPROM_Sheets_base->active_sheet)))].z_offset)),0);
|
||||
// Show the message.
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_FOLLOW_CALIBRATION_FLOW));
|
||||
}
|
||||
#ifdef TEMP_MODEL
|
||||
else if (calibration_status() == CALIBRATION_STATUS_TEMP_MODEL_CALIBRATION) {
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_TM_NOT_CAL));
|
||||
lcd_update_enable(true);
|
||||
}
|
||||
#endif //TEMP_MODEL
|
||||
else if (calibration_status() == CALIBRATION_STATUS_LIVE_ADJUST) {
|
||||
// Show the message.
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_BABYSTEP_Z_NOT_SET));
|
||||
lcd_update_enable(true);
|
||||
}
|
||||
else if (calibration_status() == CALIBRATION_STATUS_CALIBRATED && eeprom_read_byte((unsigned char *)EEPROM_TEMP_CAL_ACTIVE) && calibration_status_pinda() == false) {
|
||||
//lcd_show_fullscreen_message_and_wait_P(_i("Temperature calibration has not been run yet"));////MSG_PINDA_NOT_CALIBRATED c=20 r=4
|
||||
lcd_update_enable(true);
|
||||
}
|
||||
else if (calibration_status() == CALIBRATION_STATUS_Z_CALIBRATION) {
|
||||
// Show the message.
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_FOLLOW_Z_CALIBRATION_FLOW));
|
||||
}
|
||||
eeprom_update_byte((uint8_t*)EEPROM_CALIBRATION_STATUS_V2, calibration_status);
|
||||
}
|
||||
|
||||
#if !defined (DEBUG_DISABLE_FORCE_SELFTEST) && defined (TMC2130)
|
||||
if (eeprom_fw_version_older_than({3, 2, 0, 4}) && calibration_status() < CALIBRATION_STATUS_ASSEMBLED) {
|
||||
lcd_show_fullscreen_message_and_wait_P(_i("Selftest will be run to calibrate accurate sensorless rehoming."));////MSG_FORCE_SELFTEST c=20 r=8
|
||||
lcd_selftest();
|
||||
if (eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE)) {
|
||||
// first time run of wizard or service prep
|
||||
lcd_wizard(WizState::Run);
|
||||
}
|
||||
else if (run_wizard) {
|
||||
// some wizard steps required by the upgrade checks
|
||||
lcd_wizard(WizState::Restore);
|
||||
}
|
||||
else {
|
||||
if (!calibration_status_get(CALIBRATION_STATUS_SELFTEST)) {
|
||||
// aborted or missing wizard: show a single warning
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_FOLLOW_CALIBRATION_FLOW));
|
||||
}
|
||||
else if (!calibration_status_get(CALIBRATION_STATUS_Z)) {
|
||||
// wizard reset after service prep
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_FOLLOW_Z_CALIBRATION_FLOW));
|
||||
} else {
|
||||
// warn about other important steps individually
|
||||
if (!calibration_status_get(CALIBRATION_STATUS_LIVE_ADJUST))
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_BABYSTEP_Z_NOT_SET));
|
||||
#ifdef TEMP_MODEL
|
||||
if (!calibration_status_get(CALIBRATION_STATUS_TEMP_MODEL))
|
||||
lcd_show_fullscreen_message_and_wait_P(_T(MSG_TM_NOT_CAL));
|
||||
#endif //TEMP_MODEL
|
||||
}
|
||||
}
|
||||
#endif //TMC2130 && !DEBUG_DISABLE_FORCE_SELFTEST
|
||||
|
||||
KEEPALIVE_STATE(IN_PROCESS);
|
||||
#endif //DEBUG_DISABLE_STARTMSGS
|
||||
|
Loading…