Add zero point offset information support menu.

Note: XYZ menu is shown only if not printing and printer must me homed to show non-zero value.
This commit is contained in:
Marek Bel 2018-04-19 14:17:46 +02:00
parent b6888470cf
commit 1a80fc28e8
4 changed files with 30 additions and 0 deletions

View file

@ -1161,6 +1161,11 @@ const char * const MSG_MAX_LANG_TABLE[1] PROGMEM = {
MSG_MAX_EN
};
const char MSG_MEASURED_OFFSET_EN[] PROGMEM = "[0;0] point offset";
const char * const MSG_MEASURED_OFFSET_LANG_TABLE[1] PROGMEM = {
MSG_MEASURED_OFFSET_EN
};
const char MSG_MEASURED_SKEW_EN[] PROGMEM = "Measured skew:";
const char MSG_MEASURED_SKEW_CZ[] PROGMEM = "Merene zkoseni:";
const char * const MSG_MEASURED_SKEW_LANG_TABLE[LANG_NUM] PROGMEM = {

View file

@ -392,6 +392,8 @@ extern const char* const MSG_MARK_FIL_LANG_TABLE[LANG_NUM];
#define MSG_MARK_FIL LANG_TABLE_SELECT(MSG_MARK_FIL_LANG_TABLE)
extern const char* const MSG_MAX_LANG_TABLE[1];
#define MSG_MAX LANG_TABLE_SELECT_EXPLICIT(MSG_MAX_LANG_TABLE, 0)
extern const char* const MSG_MEASURED_OFFSET_LANG_TABLE[1];
#define MSG_MEASURED_OFFSET LANG_TABLE_SELECT_EXPLICIT(MSG_MEASURED_OFFSET_LANG_TABLE, 0)
extern const char* const MSG_MEASURED_SKEW_LANG_TABLE[LANG_NUM];
#define MSG_MEASURED_SKEW LANG_TABLE_SELECT(MSG_MEASURED_SKEW_LANG_TABLE)
extern const char* const MSG_MEASURE_BED_REFERENCE_HEIGHT_LINE1_LANG_TABLE[LANG_NUM];

View file

@ -218,6 +218,7 @@
#define(length=17,lines=1) MSG_SHOW_END_STOPS "Show end stops"
#define MSG_CALIBRATE_BED "Calibrate XYZ"
#define MSG_CALIBRATE_BED_RESET "Reset XYZ calibr."
#define MSG_MEASURED_OFFSET "[0;0] point offset"
#define(length=20,lines=8) MSG_MOVE_CARRIAGE_TO_THE_TOP "Calibrating XYZ. Rotate the knob to move the Z carriage up to the end stoppers. Click when done."
#define(length=20,lines=8) MSG_MOVE_CARRIAGE_TO_THE_TOP_Z "Calibrating Z. Rotate the knob to move the Z carriage up to the end stoppers. Click when done."

View file

@ -226,6 +226,7 @@ static void lcd_farm_no();
static void lcd_menu_extruder_info();
static void lcd_menu_xyz_y_min();
static void lcd_menu_xyz_skew();
static void lcd_menu_xyz_offset();
#if defined(TMC2130) || defined(PAT9125)
static void lcd_menu_fails_stats();
#endif //TMC2130 or PAT9125
@ -2336,6 +2337,27 @@ static void lcd_menu_xyz_skew()
lcd.print(bed_skew_angle_extreme * 180 / M_PI);
lcd.print(LCD_STR_DEGREE);
if (lcd_clicked())
{
lcd_quick_feedback();
lcd_goto_menu(lcd_menu_xyz_offset);
}
}
static void lcd_menu_xyz_offset()
{
lcd.setCursor(0,0);
lcd_printPGM(MSG_MEASURED_OFFSET);
lcd_print_at_PGM(0, 1, separator);
lcd_print_at_PGM(0, 2, PSTR("X"));
lcd_print_at_PGM(0, 3, PSTR("Y"));
for (int i = 0; i < 2; i++)
{
lcd_print_at_PGM(11, i + 2, PSTR(""));
lcd.print(world2machine_shift[i]);
lcd_print_at_PGM((world2machine_shift[i] < 0) ? 17 : 16, i + 2, PSTR("mm"));
}
if (lcd_clicked())
{
lcd_quick_feedback();