Use menu_set_block() in ThermalStop()
Set a menu block for fatal thermal errors instead of abusing lcd_return_to_status() to kick the user out of the menus. This now allows a thermal model error to be recoverable through menu access.
This commit is contained in:
parent
5e50a15c88
commit
3c1c2fd2ca
2 changed files with 12 additions and 11 deletions
|
@ -9717,14 +9717,14 @@ void UnconditionalStop()
|
|||
// WARNING: This function is called *continuously* during a thermal failure.
|
||||
//
|
||||
// This either pauses (for thermal model errors) or stops *without recovery* depending on
|
||||
// "allow_pause". If pause is allowed, this forces a printer-initiated instantanenous pause (just
|
||||
// like an LCD pause) that bypasses the host pausing functionality. In this state the printer is
|
||||
// kept in busy state and *must* be recovered from the LCD.
|
||||
void ThermalStop(bool allow_pause)
|
||||
// "allow_recovery". If recovery is allowed, this forces a printer-initiated instantanenous pause
|
||||
// (just like an LCD pause) that bypasses the host pausing functionality. In this state the printer
|
||||
// is kept in busy state and *must* be recovered from the LCD.
|
||||
void ThermalStop(bool allow_recovery)
|
||||
{
|
||||
if(Stopped == false) {
|
||||
Stopped = true;
|
||||
if(allow_pause && (IS_SD_PRINTING || usb_timer.running())) {
|
||||
if(allow_recovery && (IS_SD_PRINTING || usb_timer.running())) {
|
||||
if (!isPrintPaused) {
|
||||
lcd_setalertstatuspgm(_T(MSG_PAUSED_THERMAL_ERROR), LCD_STATUS_CRITICAL);
|
||||
|
||||
|
@ -9757,13 +9757,15 @@ void ThermalStop(bool allow_pause)
|
|||
// Make a warning sound! We cannot use Sound_MakeCustom as this would stop further moves.
|
||||
// Turn on the speaker here (if not already), and turn it off when back in the main loop.
|
||||
WRITE(BEEPER, HIGH);
|
||||
}
|
||||
|
||||
// Return to the status screen to stop any pending menu action which could have been
|
||||
// started by the user while stuck in the Stopped state. This also ensures the NEW
|
||||
// error is immediately shown.
|
||||
if (menu_menu != lcd_status_screen)
|
||||
// Always return to the status screen to ensure the NEW error is immediately shown.
|
||||
lcd_return_to_status();
|
||||
|
||||
if(!allow_recovery) {
|
||||
// prevent menu access for all fatal errors
|
||||
menu_set_block(MENU_BLOCK_THERMAL_ERROR);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
bool IsStopped() { return Stopped; };
|
||||
|
|
|
@ -1766,7 +1766,6 @@ void handle_temp_error()
|
|||
} else {
|
||||
temp_error_state.v = 0;
|
||||
WRITE(BEEPER, LOW);
|
||||
menu_unset_block(MENU_BLOCK_THERMAL_ERROR);
|
||||
|
||||
// hotend error was transitory and disappeared, re-enable bed
|
||||
if (!target_temperature_bed)
|
||||
|
|
Loading…