Add temperature model configuration for MK3
This commit is contained in:
parent
ea0840dee9
commit
49048fdcd6
1 changed files with 28 additions and 0 deletions
|
@ -413,6 +413,34 @@
|
|||
#define TEMP_RUNAWAY_EXTRUDER_HYSTERESIS 15
|
||||
#define TEMP_RUNAWAY_EXTRUDER_TIMEOUT 45
|
||||
|
||||
// model-based temperature check
|
||||
#define TEMP_MODEL 1 // enable model-based temperature checks
|
||||
#define TEMP_MODEL_DEBUG 1 // extended runtime logging
|
||||
|
||||
#define TEMP_MODEL_P 38. // heater power (W)
|
||||
|
||||
#define TEMP_MODEL_C 11. // initial guess for heatblock capacitance (J/K)
|
||||
#define TEMP_MODEL_Cl 5 // C estimation lower limit
|
||||
#define TEMP_MODEL_Ch 20 // C estimation upper limit
|
||||
#define TEMP_MODEL_C_thr 0.01 // C estimation iteration threshold
|
||||
#define TEMP_MODEL_C_itr 30 // C estimation iteration limit
|
||||
|
||||
#define TEMP_MODEL_R 25 // initial guess for heatblock resistance (K/W)
|
||||
#define TEMP_MODEL_Rl 5 // R estimation lower limit
|
||||
#define TEMP_MODEL_Rh 50 // R estimation upper limit
|
||||
#define TEMP_MODEL_R_thr 0.01 // R estimation iteration threshold
|
||||
#define TEMP_MODEL_R_itr 30 // R estimation iteration limit
|
||||
|
||||
#define TEMP_MODEL_Ta_corr -7 // Default ambient temperature correction
|
||||
#define TEMP_MODEL_LAG 2.1 // Temperature transport delay (s)
|
||||
|
||||
#define TEMP_MODEL_W 1.2 // Default warning threshold (K/s)
|
||||
#define TEMP_MODEL_E 1.74 // Default error threshold (K/s)
|
||||
|
||||
#define TEMP_MODEL_CAL_Th 230 // Default calibration working temperature (C)
|
||||
#define TEMP_MODEL_CAL_Tl 50 // Default calibration cooling temperature (C)
|
||||
|
||||
|
||||
/*------------------------------------
|
||||