Restore the "MINTEMP * fixed" message
Set the LCD messages with the correct priority
This commit is contained in:
parent
4ca0012077
commit
49a288e6cf
@ -1636,17 +1636,17 @@ public:
|
|||||||
// i.e. do not transfer to state 1
|
// i.e. do not transfer to state 1
|
||||||
break;
|
break;
|
||||||
case States::TempAboveMintemp: // the temperature has risen above the hysteresis check
|
case States::TempAboveMintemp: // the temperature has risen above the hysteresis check
|
||||||
lcd_setalertstatuspgm(m2);
|
lcd_setalertstatuspgm(m2, LCD_STATUS_CRITICAL);
|
||||||
substep(States::ShowMintemp);
|
substep(States::ShowMintemp);
|
||||||
last_alert_sent_to_lcd = LCDALERT_MINTEMPFIXED;
|
last_alert_sent_to_lcd = LCDALERT_MINTEMPFIXED;
|
||||||
break;
|
break;
|
||||||
case States::ShowPleaseRestart: // displaying "Please restart"
|
case States::ShowPleaseRestart: // displaying "Please restart"
|
||||||
lcd_setalertstatuspgm(m1);
|
lcd_setalertstatuspgm(m1, LCD_STATUS_CRITICAL);
|
||||||
substep(States::ShowMintemp);
|
substep(States::ShowMintemp);
|
||||||
last_alert_sent_to_lcd = LCDALERT_PLEASERESTART;
|
last_alert_sent_to_lcd = LCDALERT_PLEASERESTART;
|
||||||
break;
|
break;
|
||||||
case States::ShowMintemp: // displaying "MINTEMP fixed"
|
case States::ShowMintemp: // displaying "MINTEMP fixed"
|
||||||
lcd_setalertstatuspgm(m2);
|
lcd_setalertstatuspgm(m2, LCD_STATUS_CRITICAL);
|
||||||
substep(States::ShowPleaseRestart);
|
substep(States::ShowPleaseRestart);
|
||||||
last_alert_sent_to_lcd = LCDALERT_MINTEMPFIXED;
|
last_alert_sent_to_lcd = LCDALERT_MINTEMPFIXED;
|
||||||
break;
|
break;
|
||||||
@ -1702,7 +1702,7 @@ void handle_temp_error()
|
|||||||
if(temp_error_state.assert) {
|
if(temp_error_state.assert) {
|
||||||
menu_set_serious_error(SERIOUS_ERR_MINTEMP_HEATER);
|
menu_set_serious_error(SERIOUS_ERR_MINTEMP_HEATER);
|
||||||
min_temp_error(temp_error_state.index);
|
min_temp_error(temp_error_state.index);
|
||||||
} else if( menu_is_serious_error(SERIOUS_ERR_MINTEMP_HEATER) ) {
|
} else {
|
||||||
// no recovery, just force the user to restart the printer
|
// no recovery, just force the user to restart the printer
|
||||||
// which is a safer variant than just continuing printing
|
// which is a safer variant than just continuing printing
|
||||||
// The automaton also checks for hysteresis - the temperature must have reached a few degrees above the MINTEMP, before
|
// The automaton also checks for hysteresis - the temperature must have reached a few degrees above the MINTEMP, before
|
||||||
@ -1716,7 +1716,7 @@ void handle_temp_error()
|
|||||||
if(temp_error_state.assert) {
|
if(temp_error_state.assert) {
|
||||||
menu_set_serious_error(SERIOUS_ERR_MINTEMP_BED);
|
menu_set_serious_error(SERIOUS_ERR_MINTEMP_BED);
|
||||||
bed_min_temp_error();
|
bed_min_temp_error();
|
||||||
} else if( menu_is_serious_error(SERIOUS_ERR_MINTEMP_BED) ){
|
} else {
|
||||||
// no recovery, just force the user to restart the printer
|
// no recovery, just force the user to restart the printer
|
||||||
// which is a safer variant than just continuing printing
|
// which is a safer variant than just continuing printing
|
||||||
alert_automaton_bed.step(current_temperature_bed, BED_MINTEMP + TEMP_HYSTERESIS);
|
alert_automaton_bed.step(current_temperature_bed, BED_MINTEMP + TEMP_HYSTERESIS);
|
||||||
|
Loading…