Merge pull request #702 from PavelSindler/temperature_cal_fix

terminate temperature calibration
This commit is contained in:
XPila 2018-05-02 13:40:55 +02:00 committed by GitHub
commit 5d8697bdb4
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23

View file

@ -3534,8 +3534,10 @@ void process_commands()
st_synchronize();
bool find_z_result = find_bed_induction_sensor_point_z(-1.f);
if(find_z_result == false) lcd_temp_cal_show_result(find_z_result);
if (find_z_result == false) {
lcd_temp_cal_show_result(find_z_result);
break;
}
zero_z = current_position[Z_AXIS];
//current_position[Z_AXIS]
@ -3585,8 +3587,10 @@ void process_commands()
plan_buffer_line(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS], current_position[E_AXIS], 3000 / 60, active_extruder);
st_synchronize();
find_z_result = find_bed_induction_sensor_point_z(-1.f);
if (find_z_result == false) lcd_temp_cal_show_result(find_z_result);
if (find_z_result == false) {
lcd_temp_cal_show_result(find_z_result);
break;
}
z_shift = (int)((current_position[Z_AXIS] - zero_z)*axis_steps_per_unit[Z_AXIS]);
SERIAL_ECHOLNPGM("");