TM: Do not restrict autotune temperature

Fix a wrong type that prevents running TM autotune at temps >127
This commit is contained in:
Yuri D'Elia 2023-01-20 19:18:19 +01:00 committed by DRracer
parent 87118c1042
commit 6058de4ae0

View File

@ -7607,7 +7607,8 @@ Sigma_Exit:
{
// parse all parameters
float P = NAN, C = NAN, R = NAN, E = NAN, W = NAN, T = NAN;
int8_t I = -1, S = -1, B = -1, A = -1, F = -1;
int8_t I = -1, S = -1, B = -1, F = -1;
int16_t A = -1;
if(code_seen('C')) C = code_value();
if(code_seen('P')) P = code_value();
if(code_seen('I')) I = code_value_short();