Update documentation of ThermalStop()
This commit is contained in:
parent
b672be90b2
commit
7cd888cd0a
1 changed files with 5 additions and 10 deletions
|
@ -9960,17 +9960,12 @@ void UnconditionalStop()
|
|||
}
|
||||
|
||||
// Emergency stop used by overtemp functions which allows recovery
|
||||
// WARNING: This function is called *continuously* during a thermal failure.
|
||||
//
|
||||
// This function is called *continuously* during a thermal failure.
|
||||
//
|
||||
// In addition to stopping the print, this prevents subsequent G[0-3] commands to be
|
||||
// processed via USB (using "Stopped") until the print is resumed via M999 or
|
||||
// manually started from scratch with the LCD.
|
||||
//
|
||||
// Note that the current instruction is completely discarded, so resuming from Stop()
|
||||
// will introduce either over/under extrusion on the current segment, and will not
|
||||
// survive a power panic. Switching Stop() to use the pause machinery instead (with
|
||||
// the addition of disabling the headers) could allow true recovery in the future.
|
||||
// This either pauses (for thermal model errors) or stops *without recovery* depending on
|
||||
// "allow_pause". If pause is allowed, this forces a printer-initiated instantanenous pause (just
|
||||
// like an LCD pause) that bypasses the host pausing functionality. In this state the printer is
|
||||
// kept in busy state and *must* be recovered from the LCD.
|
||||
void ThermalStop(bool allow_pause)
|
||||
{
|
||||
if(Stopped == false) {
|
||||
|
|