wizard: Disable temperature model during hotend testing
This avoids confusing error messages if the hotend is defective and caught by selftest itself. Rearrange Stopped state checks (saves 2 bytes)
This commit is contained in:
parent
d8ae372309
commit
a8057e0d36
1 changed files with 13 additions and 14 deletions
|
@ -7025,6 +7025,10 @@ static bool lcd_selfcheck_check_heater(bool _isbed)
|
|||
|
||||
target_temperature[0] = (_isbed) ? 0 : 200;
|
||||
target_temperature_bed = (_isbed) ? 100 : 0;
|
||||
#ifdef TEMP_MODEL
|
||||
bool tm_was_enabled = temp_model_enabled();
|
||||
temp_model_set_enabled(false);
|
||||
#endif //TEMP_MODEL
|
||||
manage_heater();
|
||||
manage_inactivity(true);
|
||||
|
||||
|
@ -7061,26 +7065,21 @@ static bool lcd_selfcheck_check_heater(bool _isbed)
|
|||
*/
|
||||
|
||||
bool _stepresult = false;
|
||||
if (Stopped)
|
||||
if (Stopped || _opposite_result < ((_isbed) ? 30 : 9))
|
||||
{
|
||||
// thermal error occurred while heating the nozzle
|
||||
lcd_selftest_error(TestError::Heater, "", "");
|
||||
if (!Stopped && _checked_result >= ((_isbed) ? 9 : 30))
|
||||
_stepresult = true;
|
||||
else
|
||||
lcd_selftest_error(TestError::Heater, "", "");
|
||||
}
|
||||
else
|
||||
{
|
||||
if (_opposite_result < ((_isbed) ? 30 : 9))
|
||||
{
|
||||
if (_checked_result >= ((_isbed) ? 9 : 30))
|
||||
_stepresult = true;
|
||||
else
|
||||
lcd_selftest_error(TestError::Heater, "", "");
|
||||
}
|
||||
else
|
||||
{
|
||||
lcd_selftest_error(TestError::Bed, "", "");
|
||||
}
|
||||
lcd_selftest_error(TestError::Bed, "", "");
|
||||
}
|
||||
|
||||
#ifdef TEMP_MODEL
|
||||
temp_model_set_enabled(tm_was_enabled);
|
||||
#endif //TEMP_MODEL
|
||||
manage_heater();
|
||||
manage_inactivity(true);
|
||||
return _stepresult;
|
||||
|
|
Loading…
Reference in a new issue