From bd0544fe9e028ffb32d3696533340dc0319152b4 Mon Sep 17 00:00:00 2001 From: Yuri D'Elia Date: Thu, 6 Feb 2020 14:44:43 +0100 Subject: [PATCH] FS: Use two different speeds when checking for runout When doing a PAT9125 "soft check", use two different speeds between retraction and extrusion. This increases the chances that we can track the surface. --- Firmware/fsensor.cpp | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Firmware/fsensor.cpp b/Firmware/fsensor.cpp index 9e7b2f6c..7f291d7a 100755 --- a/Firmware/fsensor.cpp +++ b/Firmware/fsensor.cpp @@ -624,7 +624,7 @@ void fsensor_update(void) fsensor_oq_meassure_start(0); float e_tmp = current_position[E_AXIS]; current_position[E_AXIS] -= 3; - plan_buffer_line_curposXYZE(200/60, active_extruder); + plan_buffer_line_curposXYZE(250/60, active_extruder); current_position[E_AXIS] = e_tmp; plan_buffer_line_curposXYZE(200/60, active_extruder); st_synchronize();