Merge pull request #3417 from leptun/MK3_temperature_busy_messages
Print busy messages while waiting for heaters
This commit is contained in:
commit
ce7cccab80
2 changed files with 0 additions and 8 deletions
|
@ -5353,7 +5353,6 @@ if(eSoundMode!=e_SOUND_MODE_SILENT)
|
|||
homing_flag = true; // keep homing on to avoid babystepping while the LCD is enabled
|
||||
|
||||
lcd_update_enable(true);
|
||||
KEEPALIVE_STATE(NOT_BUSY); //no need to print busy messages as we print current temperatures periodicaly
|
||||
SERIAL_ECHOLNPGM("PINDA probe calibration start");
|
||||
|
||||
float zero_z;
|
||||
|
@ -6671,15 +6670,12 @@ Sigma_Exit:
|
|||
|
||||
/* See if we are heating up or cooling down */
|
||||
target_direction = isHeatingHotend(extruder); // true if heating, false if cooling
|
||||
|
||||
KEEPALIVE_STATE(NOT_BUSY);
|
||||
|
||||
cancel_heatup = false;
|
||||
|
||||
wait_for_heater(codenum, extruder); //loops until target temperature is reached
|
||||
|
||||
LCD_MESSAGERPGM(_T(MSG_HEATING_COMPLETE));
|
||||
KEEPALIVE_STATE(IN_HANDLER);
|
||||
heating_status = HeatingStatus::EXTRUDER_HEATING_COMPLETE;
|
||||
if (farm_mode) { prusa_statistics(2); };
|
||||
|
||||
|
@ -6722,7 +6718,6 @@ Sigma_Exit:
|
|||
cancel_heatup = false;
|
||||
target_direction = isHeatingBed(); // true if heating, false if cooling
|
||||
|
||||
KEEPALIVE_STATE(NOT_BUSY);
|
||||
while ( (!cancel_heatup) && (target_direction ? (isHeatingBed()) : (isCoolingBed()&&(CooldownNoWait==false))) )
|
||||
{
|
||||
if(( _millis() - codenum) > 1000 ) //Print Temp Reading every 1 second while heating up.
|
||||
|
@ -6745,7 +6740,6 @@ Sigma_Exit:
|
|||
lcd_update(0);
|
||||
}
|
||||
LCD_MESSAGERPGM(_T(MSG_BED_DONE));
|
||||
KEEPALIVE_STATE(IN_HANDLER);
|
||||
heating_status = HeatingStatus::BED_HEATING_COMPLETE;
|
||||
|
||||
previous_millis_cmd.start();
|
||||
|
|
|
@ -7263,7 +7263,6 @@ static bool lcd_selfcheck_check_heater(bool _isbed)
|
|||
target_temperature_bed = (_isbed) ? 100 : 0;
|
||||
manage_heater();
|
||||
manage_inactivity(true);
|
||||
KEEPALIVE_STATE(NOT_BUSY); //we are sending temperatures on serial line, so no need to send host keepalive messages
|
||||
|
||||
do {
|
||||
_counter++;
|
||||
|
@ -7316,7 +7315,6 @@ static bool lcd_selfcheck_check_heater(bool _isbed)
|
|||
|
||||
manage_heater();
|
||||
manage_inactivity(true);
|
||||
KEEPALIVE_STATE(IN_HANDLER);
|
||||
return _stepresult;
|
||||
|
||||
}
|
||||
|
|
Loading…
Reference in a new issue