Re-enable bed temperature automatically for transitory errors

This commit is contained in:
Yuri D'Elia 2022-08-21 14:48:00 +02:00
parent 30dccb3252
commit d8d085287e

View file

@ -1738,6 +1738,11 @@ void handle_temp_error()
temp_error_state.v = 0;
WRITE(BEEPER, LOW);
menu_unset_block(MENU_BLOCK_THERMAL_ERROR);
// hotend error was transitory and disappeared, re-enable bed
if (!target_temperature_bed)
target_temperature_bed = saved_bed_temperature;
SERIAL_ECHOLNPGM("TM: error cleared");
}
break;