Re-enable bed temperature automatically for transitory errors
This commit is contained in:
parent
30dccb3252
commit
d8d085287e
1 changed files with 5 additions and 0 deletions
|
@ -1738,6 +1738,11 @@ void handle_temp_error()
|
||||||
temp_error_state.v = 0;
|
temp_error_state.v = 0;
|
||||||
WRITE(BEEPER, LOW);
|
WRITE(BEEPER, LOW);
|
||||||
menu_unset_block(MENU_BLOCK_THERMAL_ERROR);
|
menu_unset_block(MENU_BLOCK_THERMAL_ERROR);
|
||||||
|
|
||||||
|
// hotend error was transitory and disappeared, re-enable bed
|
||||||
|
if (!target_temperature_bed)
|
||||||
|
target_temperature_bed = saved_bed_temperature;
|
||||||
|
|
||||||
SERIAL_ECHOLNPGM("TM: error cleared");
|
SERIAL_ECHOLNPGM("TM: error cleared");
|
||||||
}
|
}
|
||||||
break;
|
break;
|
||||||
|
|