Automaton changes. Keep heater ON during probing only if pwm is high
This commit is contained in:
parent
7650e2b60c
commit
dde61bb444
@ -140,14 +140,16 @@ ISR(TIMER0_OVF_vect) // timer compare interrupt service routine
|
||||
case States::ONE: // state ONE - we'll either stay in ONE or change to FALL
|
||||
OCR0B = 255;
|
||||
slowCounter += slowInc; // this does software timer_clk/256 or less
|
||||
if( slowCounter < pwm ){
|
||||
return;
|
||||
if (!bedPWMDisabled){ //disable heating as soon as possible
|
||||
if( slowCounter < pwm ){
|
||||
return;
|
||||
}
|
||||
if( (soft_pwm_bed << 1) >= (255 - slowInc - 1) ){ //@@TODO simplify & explain
|
||||
// if slowInc==2, soft_pwm == 251 will be the first to do short drops to zero. 252 will keep full heating
|
||||
return; // want full duty for the next ONE cycle again - so keep on heating and just wait for the next timer ovf
|
||||
}
|
||||
}
|
||||
if( (soft_pwm_bed << 1) >= (255 - slowInc - 1) ){ //@@TODO simplify & explain
|
||||
// if slowInc==2, soft_pwm == 251 will be the first to do short drops to zero. 252 will keep full heating
|
||||
return; // want full duty for the next ONE cycle again - so keep on heating and just wait for the next timer ovf
|
||||
}
|
||||
if (bedPWMDisabled){
|
||||
else if (pwm > 200){ //if duty cycle is high and BED PWM is disabled keep heater on. Prevents overcooling
|
||||
return;
|
||||
}
|
||||