Fix [French translation] Wrong display during mesh bed calibration #2218
minor code/doc improvements
This commit is contained in:
parent
14933f6b0e
commit
e7273ea505
2 changed files with 15 additions and 8 deletions
|
@ -1674,9 +1674,12 @@ static void lcd_cooldown()
|
|||
//! It would have been much easier if there was a ':' in the labels.
|
||||
//! But since the texts like Bed, Nozzle and PINDA are used in other places
|
||||
//! it is better to reuse these texts even though it requires some extra formatting code.
|
||||
//! @param [in] ipgmLabel pointer to string in PROGMEM
|
||||
//! @param [out] pointer to string in RAM which will receive the formatted text. Must be allocated to appropriate size
|
||||
//! @param [in] dstSize allocated length of dst
|
||||
static void pgmtext_with_colon(const char *ipgmLabel, char *dst, uint8_t dstSize){
|
||||
uint8_t i = 0;
|
||||
for(; i < dstSize - 2; ++i){ // 1 byte less than buffer, we'd be adding a ':' to the end
|
||||
for(; i < dstSize - 2; ++i){ // 2 byte less than buffer, we'd be adding a ':' to the end
|
||||
uint8_t b = pgm_read_byte(ipgmLabel + i);
|
||||
if( ! b )
|
||||
break;
|
||||
|
@ -1686,7 +1689,7 @@ static void pgmtext_with_colon(const char *ipgmLabel, char *dst, uint8_t dstSize
|
|||
++i;
|
||||
for(; i < dstSize - 1; ++i) // fill the rest with spaces
|
||||
dst[i] = ' ';
|
||||
dst[dstSize-1] = 0; // terminate the string properly
|
||||
dst[dstSize-1] = '\0'; // terminate the string properly
|
||||
}
|
||||
|
||||
void lcd_menu_extruder_info() // NOT static due to using inside "Marlin_main" module ("manage_inactivity()")
|
||||
|
@ -1701,9 +1704,10 @@ void lcd_menu_extruder_info() // NOT static due to using ins
|
|||
// Display Nozzle fan RPM
|
||||
lcd_timeoutToStatus.stop(); //infinite timeout
|
||||
lcd_home();
|
||||
char nozzle[12], print[12];
|
||||
pgmtext_with_colon(_i("Nozzle FAN"), nozzle, 12);
|
||||
pgmtext_with_colon(_i("Print FAN"), print, 12);
|
||||
static const size_t maxChars = 12;
|
||||
char nozzle[maxChars], print[maxChars];
|
||||
pgmtext_with_colon(_i("Nozzle FAN"), nozzle, maxChars);
|
||||
pgmtext_with_colon(_i("Print FAN"), print, maxChars);
|
||||
lcd_printf_P(_N("%s %4d RPM\n" "%s %4d RPM\n"), nozzle, 60*fan_speed[0], print, 60*fan_speed[1] );
|
||||
|
||||
#ifdef PAT9125
|
||||
|
@ -1888,9 +1892,12 @@ static void lcd_menu_debug()
|
|||
#endif /* DEBUG_BUILD */
|
||||
|
||||
//! @brief common line print for lcd_menu_temperatures
|
||||
//! @param [in] ipgmLabel pointer to string in PROGMEM
|
||||
//! @param [in] value to be printed behind the label
|
||||
static void lcd_menu_temperatures_line(const char *ipgmLabel, int value){
|
||||
char tmp[15];
|
||||
pgmtext_with_colon(ipgmLabel, tmp, 15);
|
||||
static const size_t maxChars = 15;
|
||||
char tmp[maxChars];
|
||||
pgmtext_with_colon(ipgmLabel, tmp, maxChars);
|
||||
lcd_printf_P(PSTR(" %s%3d\x01 \n"), tmp, value); // no need to add -14.14 to string alignment
|
||||
}
|
||||
static void lcd_menu_temperatures()
|
||||
|
|
|
@ -136,7 +136,7 @@
|
|||
|
||||
#MSG_CALIBRATE_Z_AUTO c=20 r=2
|
||||
"Calibrating Z"
|
||||
"Calibration de Z"
|
||||
"Calibration Z"
|
||||
|
||||
#MSG_MOVE_CARRIAGE_TO_THE_TOP_Z c=20 r=8
|
||||
"Calibrating Z. Rotate the knob to move the Z carriage up to the end stoppers. Click when done."
|
||||
|
|
Loading…