wizard: Allow finishing the calibration through menus
If the wizard is interrupted during model calibration, allow the menu to mark "temperature model" calibration as complete.
This commit is contained in:
parent
41be93735c
commit
f194bb1242
1 changed files with 10 additions and 3 deletions
|
@ -1065,9 +1065,16 @@ void lcd_commands()
|
||||||
case 1:
|
case 1:
|
||||||
lcd_commands_step = 0;
|
lcd_commands_step = 0;
|
||||||
lcd_commands_type = LcdCommands::Idle;
|
lcd_commands_type = LcdCommands::Idle;
|
||||||
if ((eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE) == 1) && temp_model_autotune_result()) {
|
|
||||||
// calibration successful, resume the wizard
|
if (temp_model_autotune_result()) {
|
||||||
lcd_wizard(WizState::IsFil);
|
if (calibration_status() == CALIBRATION_STATUS_TEMP_MODEL_CALIBRATION) {
|
||||||
|
// move to the next calibration step if not fully calibrated
|
||||||
|
calibration_status_store(CALIBRATION_STATUS_LIVE_ADJUST);
|
||||||
|
}
|
||||||
|
if ((eeprom_read_byte((uint8_t*)EEPROM_WIZARD_ACTIVE) == 1)) {
|
||||||
|
// successful: resume the wizard
|
||||||
|
lcd_wizard(WizState::IsFil);
|
||||||
|
}
|
||||||
}
|
}
|
||||||
break;
|
break;
|
||||||
}
|
}
|
||||||
|
|