Fix the "Stop print" behavior from the LCD
Correctly cleanup the printer state when stopping the current print: - Disable interrupts while aborting the planner/queue to ensure new serial commands are not inserted while aborting - _Always_ call planner_abort_hard() to interrupt any pending move! - Clear the saved_target, which might be set when calling stop from within a paused state. Create a new function to clear the paused state for future use. - Do not disable/reset the MBL: doing so will destroy the ability to restart correctly using M999.
This commit is contained in:
parent
6ab3b20ce1
commit
faa76df2fe
@ -455,6 +455,7 @@ extern void print_mesh_bed_leveling_table();
|
||||
|
||||
extern void stop_and_save_print_to_ram(float z_move, float e_move);
|
||||
extern void restore_print_from_ram_and_continue(float e_move);
|
||||
extern void cancel_saved_printing();
|
||||
|
||||
|
||||
//estimated time to end of the print
|
||||
|
@ -10343,6 +10343,14 @@ void restore_print_from_ram_and_continue(float e_move)
|
||||
waiting_inside_plan_buffer_line_print_aborted = true; //unroll the stack
|
||||
}
|
||||
|
||||
// Cancel the state related to a currently saved print
|
||||
void cancel_saved_printing()
|
||||
{
|
||||
saved_target[0] = SAVED_TARGET_UNSET;
|
||||
saved_printing_type = PRINTING_TYPE_NONE;
|
||||
saved_printing = false;
|
||||
}
|
||||
|
||||
void print_world_coordinates()
|
||||
{
|
||||
printf_P(_N("world coordinates: (%.3f, %.3f, %.3f)\n"), current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS]);
|
||||
|
@ -7258,30 +7258,25 @@ static void lcd_sd_updir()
|
||||
|
||||
void lcd_print_stop()
|
||||
{
|
||||
//-//
|
||||
if(!card.sdprinting)
|
||||
{
|
||||
if (!card.sdprinting) {
|
||||
SERIAL_ECHOLNRPGM(MSG_OCTOPRINT_CANCEL); // for Octoprint
|
||||
}
|
||||
saved_printing = false;
|
||||
saved_printing_type = PRINTING_TYPE_NONE;
|
||||
|
||||
cli();
|
||||
|
||||
// Clear any saved printing state
|
||||
cancel_saved_printing();
|
||||
cancel_heatup = true;
|
||||
#ifdef MESH_BED_LEVELING
|
||||
mbl.active = false;
|
||||
#endif
|
||||
// Stop the stoppers, update the position from the stoppers.
|
||||
if (mesh_bed_leveling_flag == false && homing_flag == false)
|
||||
{
|
||||
|
||||
// Abort the planner/queue/sd
|
||||
planner_abort_hard();
|
||||
// Because the planner_abort_hard() initialized current_position[Z] from the stepper,
|
||||
// Z baystep is no more applied. Reset it.
|
||||
babystep_reset();
|
||||
}
|
||||
// Clean the input command queue.
|
||||
cmdqueue_reset();
|
||||
lcd_setstatuspgm(_T(MSG_PRINT_ABORTED));
|
||||
card.sdprinting = false;
|
||||
card.closefile();
|
||||
st_reset_timer();
|
||||
sei();
|
||||
|
||||
lcd_setstatuspgm(_T(MSG_PRINT_ABORTED));
|
||||
stoptime = _millis();
|
||||
unsigned long t = (stoptime - starttime - pause_time) / 1000; //time in s
|
||||
pause_time = 0;
|
||||
|