Add the ability to log continuously
TEMP_MODEL_LOGGING enables D70 to record precisely each cycle of the temperature regulation for offline model simulation
This commit is contained in:
parent
690affe5a2
commit
fabf511b97
4 changed files with 97 additions and 0 deletions
|
@ -9144,6 +9144,14 @@ Sigma_Exit:
|
|||
};
|
||||
#endif
|
||||
|
||||
#ifdef TEMP_MODEL_LOGGING
|
||||
case 70: {
|
||||
if(code_seen('I'))
|
||||
temp_model_log_enable(code_value_short());
|
||||
break;
|
||||
}
|
||||
#endif
|
||||
|
||||
#ifdef HEATBED_ANALYSIS
|
||||
|
||||
/*!
|
||||
|
|
|
@ -500,6 +500,11 @@ void set_temp_error(TempErrorSource source, uint8_t index, TempErrorType type)
|
|||
|
||||
void handle_temp_error();
|
||||
|
||||
#ifdef TEMP_MODEL_LOGGING
|
||||
static void temp_model_log_usr();
|
||||
static void temp_model_log_isr();
|
||||
#endif
|
||||
|
||||
void manage_heater()
|
||||
{
|
||||
#ifdef WATCHDOG
|
||||
|
@ -520,6 +525,10 @@ void manage_heater()
|
|||
|
||||
// periodically check fans
|
||||
checkFans();
|
||||
|
||||
#ifdef TEMP_MODEL_LOGGING
|
||||
temp_model_log_usr();
|
||||
#endif
|
||||
}
|
||||
|
||||
#define PGM_RD_W(x) (short)pgm_read_word(&x)
|
||||
|
@ -2200,6 +2209,10 @@ static void temp_mgr_isr()
|
|||
check_temp_model(); // model-based heater check
|
||||
#endif
|
||||
|
||||
#ifdef TEMP_MODEL_LOGGING
|
||||
temp_model_log_isr();
|
||||
#endif
|
||||
|
||||
// PID regulation
|
||||
if (pid_tuning_finished)
|
||||
temp_mgr_pid();
|
||||
|
@ -2390,4 +2403,76 @@ static void check_temp_model()
|
|||
set_temp_error(TempErrorSource::hotend, 0, TempErrorType::model);
|
||||
}
|
||||
}
|
||||
|
||||
#ifdef TEMP_MODEL_LOGGING
|
||||
static struct
|
||||
{
|
||||
volatile struct
|
||||
{
|
||||
uint32_t stamp;
|
||||
int8_t delta_ms;
|
||||
uint8_t counter;
|
||||
uint8_t cur_pwm;
|
||||
float cur_temp;
|
||||
float cur_amb;
|
||||
} entry;
|
||||
|
||||
uint8_t serial;
|
||||
bool enabled;
|
||||
} temp_model_log_buf;
|
||||
|
||||
static void temp_model_log_usr()
|
||||
{
|
||||
if(!temp_model_log_buf.enabled)
|
||||
return;
|
||||
|
||||
uint8_t counter = temp_model_log_buf.entry.counter;
|
||||
if (counter == temp_model_log_buf.serial)
|
||||
return;
|
||||
|
||||
int8_t delta_ms;
|
||||
uint8_t cur_pwm;
|
||||
float cur_temp;
|
||||
float cur_amb;
|
||||
{
|
||||
TempMgrGuard temp_mgr_guard;
|
||||
delta_ms = temp_model_log_buf.entry.delta_ms;
|
||||
counter = temp_model_log_buf.entry.counter;
|
||||
cur_pwm = temp_model_log_buf.entry.cur_pwm;
|
||||
cur_temp = temp_model_log_buf.entry.cur_temp;
|
||||
cur_amb = temp_model_log_buf.entry.cur_amb;
|
||||
}
|
||||
|
||||
uint8_t d = counter - temp_model_log_buf.serial;
|
||||
temp_model_log_buf.serial = counter;
|
||||
|
||||
printf_P(PSTR("TML %d %d %x %lx %lx\n"), (unsigned)d - 1, (int)delta_ms + 1, (int)cur_pwm,
|
||||
*(unsigned long*)&cur_temp, *(unsigned long*)&cur_amb);
|
||||
}
|
||||
|
||||
static void temp_model_log_isr()
|
||||
{
|
||||
if(!temp_model_log_buf.enabled)
|
||||
return;
|
||||
|
||||
uint32_t stamp = _millis();
|
||||
uint8_t delta_ms = stamp - temp_model_log_buf.entry.stamp - (TEMP_MGR_INTV * 1000);
|
||||
temp_model_log_buf.entry.stamp = stamp;
|
||||
|
||||
++temp_model_log_buf.entry.counter;
|
||||
temp_model_log_buf.entry.delta_ms = delta_ms;
|
||||
temp_model_log_buf.entry.cur_pwm = soft_pwm[0];
|
||||
temp_model_log_buf.entry.cur_temp = current_temperature_isr[0];
|
||||
temp_model_log_buf.entry.cur_amb = current_temperature_ambient_isr;
|
||||
}
|
||||
|
||||
void temp_model_log_enable(bool enable)
|
||||
{
|
||||
if(enable) {
|
||||
TempMgrGuard temp_mgr_guard;
|
||||
temp_model_log_buf.entry.stamp = _millis();
|
||||
}
|
||||
temp_model_log_buf.enabled = enable;
|
||||
}
|
||||
#endif
|
||||
#endif
|
||||
|
|
|
@ -228,6 +228,9 @@ FORCE_INLINE void autotempShutdown(){
|
|||
}
|
||||
|
||||
void PID_autotune(float temp, int extruder, int ncycles);
|
||||
#ifdef TEMP_MODEL_LOGGING
|
||||
void temp_model_log_enable(bool enable);
|
||||
#endif
|
||||
|
||||
#ifdef FAN_SOFT_PWM
|
||||
extern unsigned char fanSpeedSoftPwm;
|
||||
|
|
|
@ -420,6 +420,7 @@
|
|||
// model-based temperature check
|
||||
#define TEMP_MODEL_CHECK 1
|
||||
#define TEMP_MODEL_CHECK_WARN_ONLY 1
|
||||
#define TEMP_MODEL_LOGGING 1
|
||||
|
||||
/*------------------------------------
|
||||