Commit Graph

9 Commits

Author SHA1 Message Date
Yuri D'Elia
502bc8c72d Isolate more pat9125 code
Remove probing from Marlin_main and move it into pat9125_probe so that
it can support the various variants.
2020-08-20 15:34:46 +02:00
Yuri D'Elia
3be859ece9 FS: Improve reliability on speeds with poor optical tracking
Depending on the filament surface and moving speed, the PAT9125 sensor
can stop being able to track movement.

In such cases, instead of triggering false errors and/or relying on
previous states, read and use the exposure data off the sensor and
increase error counts only for poorly exposed images instead, which
is a good indicator of a far-away (or missing!) tracking surface.
2020-02-06 15:27:22 +01:00
Robert Pelnar
b35a212d15 PAT9125 optimalization (rewrited to C, 8bit sampling) 2018-07-12 18:11:07 +02:00
bubnikv
44dc12005f Optimization of the filament sensor. 2018-01-23 16:47:42 +01:00
Robert Pelnar
cddb0eafb8 PAT9125 - sampled only Y value, new debug code D9125.
FSensor - synchronous sampling and new algorithm
build number = 103
2017-10-24 19:45:15 +02:00
Robert Pelnar
683784c4c7 PAT9125 I2C, hardware SG homing
separate pin configuration file for each board
changed board codes:
RAMBO =100, MiniRambo1.0 =200, MiniRambo1.3 = 203, Einy03 =303, Einy04 =304
2017-08-17 15:23:34 +02:00
Robert Pelnar
ec7678a25f pat9125 filament sensor
sg homing - bug fix + homing multiple axes simultanously (AXIS_MASK)
2017-07-07 04:45:09 +02:00
Robert Pelnar
f6a8e1df9d TMC2130 + software SG homing + LF lineendings + tmc2130 debug M-Codes
M910 - tmc2130_init
M911 - set holding currents
M912 - set running currents
M913 - print currents
2017-07-01 12:39:16 +02:00
michalprusa
6f3c28c4a7 Filament sensor PAT9125 implemented 2017-06-17 20:40:22 +02:00