Commit Graph

3150 Commits

Author SHA1 Message Date
Alex Voinea
160af0a624
Printer capabilities 2020-09-11 16:11:28 +03:00
DRracer
f145769e98
Merge pull request #2807 from leptun/MK3_Polling
M220 M221 polling of values
2020-09-09 10:25:36 +02:00
DRracer
763d2d9849
Merge pull request #2806 from leptun/MK3_PRUSA_SN
Make the serial number available to the user
2020-09-09 09:54:29 +02:00
DRracer
a0420c7928
Merge pull request #2619 from 3d-gussner/MK3_G21
Add dummy G21 to prevent UNKOWN warnings in serial
2020-09-09 09:22:07 +02:00
DRracer
b82ee3fc06
Merge pull request #2811 from leptun/MK3_fastio_timer_patch
Fix fastio extra parenthesis
2020-09-09 08:57:37 +02:00
DRracer
a2db9e8f6b
Merge pull request #2585 from leptun/MK3_FEEDRATE
🐛♻️ Update the feedrate percentage before drawing the screen
2020-09-09 08:56:46 +02:00
Alex Voinea
7ac16d5f04
Menu view return patch 2020-09-07 19:42:53 +03:00
Alex Voinea
1659f61dd5
Fix fastio extra parenthesis 2020-08-21 10:51:46 +03:00
DRracer
772844678f
Merge pull request #2809 from leptun/PFW-1134-ALTFAN_KILLSWITCH
Pfw 1134
2020-08-20 15:42:03 +02:00
3d-gussner
90c36a5887
Update ALTFAN eeprom documentation
EEPROM_ALTFAN_OVERRIDE and EEPROM_EXPERIMENTAL_VISIBILITY are compared to 0xFF in the code that's why I keep the uint8.
2020-08-20 15:14:39 +02:00
Alex Voinea
2c2926882a
Don't switch unnecessarily. Also "\n" the ";S" request 2020-08-18 19:29:18 +03:00
Alex Voinea
8d9dc73d1b
Fix compile error
fix compile


Fix compile error
2020-08-12 17:25:49 +03:00
Alex Voinea
5530b99882
Reboot after factory reset 2020-08-12 12:46:35 +03:00
Alex Voinea
6b853a4cc3
Auto-detect ALTFAN after fw. update 2020-08-12 12:19:08 +03:00
Alex Voinea
96435ad084
Move experimental menu to HW setup 2020-08-12 08:48:12 +03:00
DRracer
008d3b0e65
Merge pull request #2792 from wavexx/MK3_fix_high_speed_deceleration
Mk3 fix high speed deceleration
2020-08-06 13:27:52 +02:00
DRracer
89ecf2ce3a
Merge pull request #2791 from wavexx/stack_protect_reentrant_isr
Fix stack smashing in temperature/fsensor ISR
2020-08-06 13:26:33 +02:00
DRracer
d0eca4d5c4
Merge pull request #2794 from leptun/PFW-1134-ALTFAN_KILLSWITCH
Minor documentation fixes to altfan PR
2020-08-06 12:53:34 +02:00
Alex Voinea
f1a8657093
Minor documentation fixes
Add even more comments


a
2020-08-06 12:20:38 +03:00
DRracer
22a8c18551
Merge pull request #2784 from leptun/PFW-1134-ALTFAN_KILLSWITCH
altfan killswitch
2020-08-06 08:15:42 +02:00
Yuri D'Elia
b3af08d94a Fix stack smashing in temperature/fsensor ISR
The temperature and fsensor ISR re-enable interrupts while executing.

However, we still need to protect the epilogue of the ISR so that
the saved return address is not altered while returning.

We hoist the body of the function out of the isr in both cases for
clarity (and to avoid a stray return bypassing the lock/cli), so that
the re-entrant portion is clearly indicated.

This should fix the "STATIC MEMORY OVERWRITTEN" error messages randomly
happening when stepping at high frequency (where either isr is
preempted more frequently).
2020-08-05 17:47:46 +02:00
DRracer
f1bde1a039
Merge pull request #2724 from wavexx/max_ambient
Implement MIN/MAX AMBIENT safety checks
2020-08-05 08:52:55 +02:00
Yuri D'Elia
a2c7dcbbf8 Fix indentation 2020-08-04 13:14:35 +02:00
Alex Voinea
654a3a0d79
Other requested changes 2020-08-04 10:43:30 +03:00
Alex Voinea
e0bf92cd4e
Change bool literal to int 2020-08-04 09:54:57 +03:00
Yuri D'Elia
b8e8f182ca Add reference C implementations for MultiU16X8toH16/MultiU24X24toH16
Higher step counts might still overflow the ASM MultiU24X24toH16.

e4595fa24a
2020-08-03 19:03:13 +02:00
Yuri D'Elia
30a806608f Also convert acceleration_rate to uint32_t
acceleration_rate is also unsigned
2020-08-03 19:01:38 +02:00
Yuri D'Elia
aebaca5cdc Correct comments regarding acceleration ramp
Backport fixes from upstream Marlin
2020-08-03 18:53:13 +02:00
Yuri D'Elia
8108d50b59 Reintroduce/fix check for step_rate underflow during deceleration
Check for negative results and results under the final_rate
2020-08-03 18:53:13 +02:00
Yuri D'Elia
4654283f54 Restore indentation 2020-08-03 18:16:20 +02:00
Alex Voinea
12be141188 Fix high speed deceleration 2020-08-03 18:16:13 +02:00
Yuri D'Elia
a8ce9358e5 Avoid redundant temperature error strings
Factor-out MIN/MAXTEMP [BED/AMB] out of the error message, which is now
built at runtime instead.

Introduce two missing ultralcd functions lcd_setalertstatus and
lcd_updatestatus to handle regular strings.

246272 -> 246084 = 188 bytes saved
2020-08-01 17:47:42 +02:00
Yuri D'Elia
e1c79c342d Re-introduce redundant disable_heaters() calls
Partially revert 285b505c73a54e9af01816e3a614de73ad181851 so that
we ensure heaters are disabled ASAP in case of potential bugs
in the max_*_error functions.
2020-08-01 17:47:20 +02:00
Yuri D'Elia
a60ed81a35 Implement MIN/MAX AMBIENT safety checks
Take advantage of the NTC thermistor found on the Einsy as an additional
safety measure, following the steps of the other MIN/MAXTEMP errors.

Introduce two configurable params AMBIENT_MINTEMP and AMBIENT_MAXTEMP
in the variant defines and set them for the MK3/MK3S to -30/+100
respectively.

AMBIENT_MINTEMP is primarily intended to catch a defective board
thermistor (to ensure MAXTEMP would be properly triggered) and thus the
trigger temperature is set just above the sensing limit and well below
the operating range.

AMBIENT_MAXTEMP is set at 100C, which is instead 20C above the maximum
recommended operating temperature of the Einsy. The NTC thermistor is
located just above the main power connector on the bottom of the board,
and could also help in detecting a faulty connection which can result in
rapid overheating of the contacts.

As for MAXTEMP, we cut power to the heaters, print fan and motors to
reduce power draw. Resume is not possible except by resetting the
printer, since the user is highly advised to inspect the board for
problems before attempting to continue.
2020-08-01 17:38:10 +02:00
Yuri D'Elia
3336db7954 Add some important notes about thermistor ADC handling 2020-08-01 17:36:43 +02:00
Yuri D'Elia
65f25b0d7e Remove redundant disable_heater() calls in max/min_temp handling
In max/min_temp handlers remove the redundant disable_heater() call.
Handlers already need to call Stop(), which will disable all heaters
as the first step.

Fix comments in order to mention that all heaters get disabled.
Use "MAX/MINTEMP BED" correctly in both the LCD and serial.
2020-08-01 17:36:43 +02:00
Yuri D'Elia
942fca5b66 Remove useless assignment
target_temperature_bed is already reset by disable_heaters() in Stop()
2020-08-01 17:36:43 +02:00
Yuri D'Elia
87bc5a78b6 Remove bogus comment (BED_MINTEMP *is* implemented) 2020-08-01 17:36:43 +02:00
Yuri D'Elia
feafc5e5ab Alternative schedule for LA ticks
Remove most of the original complexity from advance_spread.

Instead of accumulating time to be scheduled, plan ahead of time each
eISR tick using the next main interval + an accumulator (eISR_Err),
which keeps everything much simpler.

The distribution of the advance ticks is now using the real LA
frequency, which leaves a bit more time between the last LA tick and
the main stepper isr.

We take advantage of the accumulator to force a LA tick right after the
first main tick, which removes a +/- 1 scheduling error at higher step
rates.

When decompressing, we force 2 steps instead, so that the direction
reversal happens immediately (first tick zeros esteps, second inverts
the sign), removing another +/- 1 error at higher step rates.
2020-07-29 19:14:48 +02:00
Alex Voinea
773c6997ef
Add comments 2020-07-29 17:36:03 +03:00
Alex Voinea
ec6a20971e
Add experimental menu to HW_setup 2020-07-29 11:23:24 +03:00
Alex Voinea
e2856ba4f5
Make the serial number available to the user 2020-07-21 12:52:04 +03:00
Alex Voinea
a95feb56d9
ALTFAN override 2020-07-20 19:35:25 +03:00
Yuri D'Elia
a08ca19ade Make flow correction optional, disabled by default
If you're using flow to correct for an incorrect source diameter, which
is probably the main usage when using the LCD, then LA shouldn't be
adjusted.

It's still unclear what the effect of M221 in gcode should be regarding
overall extrusion width. If M221 means "thicker lines", then LA should
also be adjusted accordingly.

This stems from the fact that the source diameter/length needs to be
known in order to determine a compression factor which is independent of
the extrusion width, but the FW only ever sees one value currently (the
extrusion length) which combines both.

This makes it impossible for the FW to adjust for one OR the other
scenario, depending on what you expect for M221 to mean.
2020-07-20 14:33:45 +02:00
Yuri D'Elia
9b8f642b28 Account for flow adjustments in LA
The e/D ratio should be calculated using the extrusion length.

As such, purify the e_D_ratio from the current extruder multiplier in
order to account correctly for flow adjustments.
2020-07-19 17:41:38 +02:00
Yuri D'Elia
c54474f2db Guard against planning/numerical errors in short segments
Turns out for high-res curved models the numerical error and the
SLOWDOWN handling in the planner can cause enough variance in the
calculated pressure to trigger LA to continuosly, making matters worse.

Clamp LA again, but only during extrusion, so that the runaway error is
limited by the current segment length.
2020-07-16 18:54:00 +02:00
Yuri D'Elia
fb5f09da6d Fix incorrect precedence for retraction phase
The logic was inverted, causing the fastest isr to always retract
instead of counter-balance the acceleration properly.
2020-07-16 18:53:53 +02:00
Yuri D'Elia
c08f37da96 Use nominal rate for phase calculations
The local interval calculated by advance_spread() might oscillate too
much in narrow intervals.
2020-07-12 17:15:47 +02:00
Yuri D'Elia
f1efce7e52 Handle LA termination with double/quad stepping properly
Before PR #2591 LA was automatically capped during cruising or
deceleration. However we now rely on reaching the current pressure state
exactly to stop. When dual/quad stepping inside the eISR we might incur
in oscillating behavior if we do not handle it correctly.

This might be the cause behind #2757

This now changes e_step_loops to be a phase-local variable, so we now
reset it each phase too (instead of per-segment).
2020-06-23 16:51:54 +02:00
Yuri D'Elia
50a09824fd Avoid scheduling useless eISR ticks
When switching to a new trapezoid step with the right pressure, cancel
any pending eISR right away.

Similarly do not schedule another eISR if the pressure will be reached
by the end of the eISR.

This was done in the past to preserve the current LA_phase. This is not
needed anymore, since it will be reset at each trapezoid step when LA
is re-initialized.
2020-06-23 15:24:16 +02:00