Robert Pelnar
8409a26594
Live adjust Z - display zero in case of invalid calibration status (same logic in babystep_load and _lcd_babystep)
2018-08-10 19:55:50 +02:00
Robert Pelnar
e22d204e8e
LCD menu optimalization - print functions
...
+removed unused code
2018-07-16 19:29:27 +02:00
Robert Pelnar
68e59399af
LCD menu optimalization - lcd_printPGM replaced with lcd_puts_P
2018-07-16 18:08:01 +02:00
Robert Pelnar
b6223d5623
LCD menu optimalization
2018-07-16 04:13:26 +02:00
mkbel
02bd319a6c
Merge pull request #818 from 3d-gussner/MK3_fix7
...
Fix warning #7
2018-07-11 21:04:13 +02:00
3d-gussner
c29042dead
Fix warning:
...
Another fix from PR https://github.com/prusa3d/Prusa-Firmware/pull/138 and discussed in Issue https://github.com/prusa3d/Prusa-Firmware/issues/807
Ardunio IDE 1.6.8 and 1.8.5 result with Compiler warnings set to "More" or "All"
´´´
sketch\mesh_bed_calibration.cpp: In function 'sample_mesh_and_store_reference':
sketch\mesh_bed_calibration.cpp:2852:53: warning: 'zmax' may be used uninitialized in this function [-Wmaybe-uninitialized]
zmax = min(zmax, mbl.z_values[j][i]);
^
sketch\mesh_bed_calibration.cpp:2848:15: note: 'zmax' was declared here
float zmax = zmax;
^
´´´
2018-06-08 10:13:43 +02:00
Robert Pelnar
47c68c884c
New ML support - fixed duplicate strings
2018-06-01 14:35:03 +02:00
PavelSindler
d307868a90
merge with upstream
2018-05-28 20:38:55 +02:00
PavelSindler
7e79ce8e53
MK3: crash detection for Z axis is active during auto home and mesh bed leveling (normal mode is forced for Z movents); temp cal coordintes corrections; temp cal: xy movents always in safe Z distance from heatbed, Z-axis homing improved
2018-05-28 20:26:15 +02:00
Robert Pelnar
2cf20c8c99
New ML support - migration - fix_source_1.sh script (replace 'MSG_xx' with '_T(MSG_xx)')
...
+ output + fixed source
2018-05-23 16:37:08 +02:00
Robert Pelnar
bd587faab9
New ML support - migration - replaced source, removed original ML support files (backup)
2018-05-22 03:20:03 +02:00
XPila
a184d2b824
Merge pull request #756 from XPila/MK3-new_lang
...
Mk3 new lang
2018-05-20 13:26:28 +02:00
Robert Pelnar
a528f8837c
Merge remote-tracking branch 'upstream/MK3' into MK3-new_lang
2018-05-20 13:24:52 +02:00
Marek Bel
503d5551e6
Fix build of MK2. Global variable distance_from_min was removed, do not update it.
...
Expression
float y = vec_x[1] * pgm_read_float(bed_ref_points_4+mesh_point*2) + vec_y[1] * pgm_read_float(bed_ref_points_4+mesh_point*2+1) + cntr[1];
is identical with expression in count_xyz_details().
2018-05-16 18:40:36 +02:00
PavelSindler
553779a65d
Merge pull request #723 from mkbel/refactor_bed_geometry
...
Refactor bed geometry
2018-05-14 17:18:03 +02:00
Marek Bel
329ea199ec
Show measured bed offset from expected position even if not homed. Remove redundant lcd_quick_feedback() calls.
2018-05-10 18:24:49 +02:00
Robert Pelnar
59f3f9d8ec
New localization - includes fixed
2018-05-09 16:55:41 +02:00
Marek Bel
f00bde09a4
Re-factor bed calibration point coordinates to match bed CAD data. Tested successfully on MK3 (auto home position not calibrated and calibrated printer and print area position of calibrated printer). MK25 not tested.
2018-05-08 21:54:11 +02:00
Marek Bel
d6aa149cfa
Conserve 58 bytes of flash by returning by reference.
2018-04-26 16:36:02 +02:00
Marek Bel
ae08788c99
Split lcd_service_mode_show_result screens to separate functions. Make them non blocking. Remove global array distance_from_min, pass it as function return value. Make Support submenus returning to Support menu.
2018-04-26 16:36:02 +02:00
PavelSindler
e7ad81e159
Merge pull request #660 from mkbel/fix_z_home_point
...
Update documentation of mesh_bed_calibration.cpp.
2018-04-25 17:27:22 +02:00
Robert Pelnar
0271ab3643
Meshbedleveling, calibration Z
...
check crash Z (MK3)
check deviation of Z-probe (>50um == error, all printers)
kill with message "debris on nozzle..."
2018-04-25 16:19:16 +02:00
Robert Pelnar
5f12289339
CalibrationZ/MK3 - check crash Z after homeaxis (kill with message "debris on nozzle...")
2018-04-25 14:43:32 +02:00
Marek Bel
3abfeb831f
Update documentation of mesh_bed_calibration.cpp.
2018-04-25 12:21:20 +02:00
Marek Bel
37ebe5c35d
Move default correction matrix of not calibrated printer to world2machine_default() function. Use world2machine_reset() to uncorrected matrix. Call it from world2machine_revert_to_uncorrected() and from world2machine_default() if there is no default shift to remove code duplication.
2018-04-23 20:33:39 +02:00
Marek Bel
82b31e8552
Set [0;0] point offset for uncalibrated printer.
2018-04-20 15:01:11 +02:00
Marek Bel
31ae097dba
mesh bed leveling / auto home Y coordinates updated
2018-04-18 17:09:12 +02:00
Robert Pelnar
339d2ebdef
Z-axis stealth mode
...
XYZcal fix
2018-04-03 18:26:39 +02:00
Robert Pelnar
3ff5686336
MK2-25-3 variant files
2018-03-14 13:53:36 +01:00
Robert Pelnar
ac1a56b493
Merge branch 'MK25' into MK3
2018-03-13 20:43:19 +01:00
Robert Pelnar
65a91b366d
New XYZ calibration with image processing
2018-03-13 12:55:35 +01:00
Robert Pelnar
a6f900fd3c
Merge remote-tracking branch 'upstream/MK25' into MK25
...
# Please enter a commit message to explain why this merge is necessary,
# especially if it merges an updated upstream into a topic branch.
#
# Lines starting with '#' will be ignored, and an empty message aborts
# the commit.
2018-03-06 15:11:50 +01:00
PavelSindler
a4b3389dfa
M45 verbosity, steel sheet define, minor modifications in xyz cal
2018-02-22 10:38:46 +01:00
PavelSindler
43b8b125bc
calibration points/offset corrections
2018-02-19 11:38:52 +01:00
Robert Pelnar
546314fda7
Removed debug messages from serial comunication (octoprint...).
...
build 137b
2017-12-27 20:29:24 +01:00
PavelSindler
d7db407f32
xyz cal.: add delay_keep_alive messages to reset watchdog (LS optimization method takes more than 4s in some cases)
2017-12-05 13:16:59 +01:00
PavelSindler
ba1bb4aea3
whitespace
2017-11-22 19:18:32 +01:00
PavelSindler
6d0574dd0f
changed Y_MIN and probe points coordinates
2017-11-22 19:13:34 +01:00
PavelSindler
6bd221ad3b
Y distance between nozzle and PINDA corrected
2017-11-22 16:07:03 +01:00
PavelSindler
fbbcc27f1a
X max lowered to 250, XYZ/Z calibration: Z top coordinate changed, changes in xyz cal. because of stell sheet, still not final version
2017-11-12 11:30:06 +01:00
PavelSindler
c36b7be90c
SUPPORT_VERBOSITY initial version
2017-11-07 11:36:41 +01:00
PavelSindler
c4d7b801b9
Initial version. XYZ cal works, but bed ref. points coordinates must be checked.
2017-10-27 16:12:37 +02:00
Robert Pelnar
480838a0a1
Fixed homing (mbl and babystep - crashdetection recovery work fine now).
2017-09-23 16:35:01 +02:00
PavelSindler
6eb57da770
fan check can be turned off from support menu, saving parameters to eeprom with offset and different levels, fan kickstart,2nd heatbed version, fans check modified
2017-09-21 15:20:02 +02:00
Robert Pelnar
683784c4c7
PAT9125 I2C, hardware SG homing
...
separate pin configuration file for each board
changed board codes:
RAMBO =100, MiniRambo1.0 =200, MiniRambo1.3 = 203, Einy03 =303, Einy04 =304
2017-08-17 15:23:34 +02:00
michalprusa
3fdb630c42
Mesh bed leveling calibrated to new MK42 24V heatbed (rev 0.3b)
...
Increased currents in Z and E axis
Decreased stallguard sensitivity
E axis microsteps changed to 64
2017-07-06 20:40:56 +02:00
PavelSindler
43d696659f
3.0.12-RC2 sync
2017-06-29 18:35:43 +02:00
michalprusa
3faef75a0d
3.0.10 sync
2017-03-24 19:47:50 +01:00
bubnikv
b470e103dc
Reset live adjust on XYZ calibration.
...
Disable timeouts in the XYZ/Z calibration.
Don't modify feed rate multiplier during the XYZ/Z calibration.
Support multi screen messages in the XYZ/Z calibration - "move the Z carriages up" step.
Support up to three lines in the XYZ/Z calibration messages.
Added a new message "Measuring reference height of calibration point xx of 9".
Changed the "move the Z carriages up" message to suggest rotating the knob.
Changed the "live adjust not set" message to reference the manual chapter and section.
Remove debugging serial line output on Z calibration.
2016-09-01 10:44:24 +02:00
bubnikv
26405ee16f
Syncing with 3.0.7 public
2016-08-31 17:12:05 +02:00