PavelSindler
16fffed52d
current feedrate and fan speed stored to eeprom in power panic, number of blocks (linear movements) in planner serve for counting SD card recover position, print fan speed error limit prolonged to 15s
2017-07-05 15:04:43 +02:00
PavelSindler
a8678cb2fd
recover print
2017-07-04 11:31:39 +02:00
PavelSindler
d05e62813a
Merge remote-tracking branch 'upstream/MK3' into MK3
...
sync with upstream
2017-07-03 14:08:39 +02:00
Robert Pelnar
e09f0c64c7
TMC2130 tuning, silent/high power mode
2017-07-03 07:43:50 +02:00
PavelSindler
17074e1d25
saving/restoring filename and current position in bytes to eeprom, UVLO changed
2017-07-02 21:01:23 +02:00
PavelSindler
ae0c64248f
sync with upstream
2017-07-01 19:29:57 +02:00
PavelSindler
c4be651d2b
uvlo initial version
2017-07-01 18:51:02 +02:00
Robert Pelnar
4f9a8147a4
renamed EINY 0.1a to EINY 0.3a
...
added EINY 0.4a
changed jerk (optimized for MK3 silent mode)
2017-07-01 17:28:32 +02:00
Robert Pelnar
f6a8e1df9d
TMC2130 + software SG homing + LF lineendings + tmc2130 debug M-Codes
...
M910 - tmc2130_init
M911 - set holding currents
M912 - set running currents
M913 - print currents
2017-07-01 12:39:16 +02:00
PavelSindler
43d696659f
3.0.12-RC2 sync
2017-06-29 18:35:43 +02:00
michalprusa
21177476ac
StallGuard homing implemented, working
2017-06-17 16:58:36 +02:00
michalprusa
3e642d61cb
Stepper Y inverted, current lowered.
2017-06-17 15:58:26 +02:00
michalprusa
cabaec95c8
EINY implementation
2017-03-24 20:16:03 +01:00
michalprusa
3faef75a0d
3.0.10 sync
2017-03-24 19:47:50 +01:00
bubnikv
99ae9707de
Fixed a missing SD card error on start up, if the setup was blocked
...
by some dialog for an extended period of time.
Increased version to 3.0.8 final.
2016-09-01 16:52:46 +02:00
bubnikv
b470e103dc
Reset live adjust on XYZ calibration.
...
Disable timeouts in the XYZ/Z calibration.
Don't modify feed rate multiplier during the XYZ/Z calibration.
Support multi screen messages in the XYZ/Z calibration - "move the Z carriages up" step.
Support up to three lines in the XYZ/Z calibration messages.
Added a new message "Measuring reference height of calibration point xx of 9".
Changed the "move the Z carriages up" message to suggest rotating the knob.
Changed the "live adjust not set" message to reference the manual chapter and section.
Remove debugging serial line output on Z calibration.
2016-09-01 10:44:24 +02:00
bubnikv
26405ee16f
Syncing with 3.0.7 public
2016-08-31 17:12:05 +02:00
michalprusa
307d17422d
3.0.6 sync
2016-08-11 10:42:53 +02:00
michalprusa
30f0528aba
Initial commit
2016-07-22 15:28:01 +02:00