User can en/disable the fan check during print. This is very useful in case of false positive
fan errors to let the user to decide to finish print with "faulty" fan.
Another request from our Service dept. - the user shall be prevented
from skipping the intro wizard, because otherwise some preset/calibrated
features will look like not done - especially live-z calibration.
And since there are users, who send a machine to service to perform 1st
layer calibration only, they must not omit the Z-calibration at the
start after shipping.
- If `M73` `R,S,C,D` values set the LCD Info screen clock switchs between Remaining and Change time
- If Remaining time is 0 while Change time is >0 the clock switchs between Change time and actual printing time
- If Change is 0 while Remaining time is >0 the clock shows the Remaining time
- If both are 0 the clock shows the actual printing time
- `M73 C` values are shown in "Normal" mode
- `M73 D` values are shown in "Stealth" mode
- Changing the speed will try to calculate the espected times and show `?` behind `R` or `C`
- Add parameter `C` to gcode `M73`
- LCD Info screen switches to change time if last `M73` gcode contains `C` parameter
- Examples:
- `M73 P5 R120` will display on LCD ` SD 5% 02:00R ` if it is printing at 100% speed
- `M73 P5 R120 C60` will display on LCD ` SD 5% 01:00C ` if it is printing at 100% speed
Slicers can generate "Time to change/pause/user interaction" using `C<mins:0-65535>` parameter to "overwrite" the remaining print time.
To switch between time to change and remaining time just send in intervals `M73` with or without `C` parameter.
... looks like I've been able to reduce the code by 80B by using the
clamp999() function. There are other spots this function can be used as
well, I didn't touch those yet.
upon request from our Service dept. - it is to do the same stuff like
Shipping prep., but keep the printer's stats intact. Still, this has to
be verified and may undergo some further changes.
Depending if SD or USB/host print the firmware sends
- SD print: `// action:paused` or `// action:resumed` are send to inform USB/Host
- USB/host print: `// action:pause` or `// action:resume` are send to trigger the USB/host to handle it
- USB/host must handle `// action:pause` and `// action:resume` correctly to work
- Tested with Octoprint
- It handles every thing correctly
- Any combination of Octoprint and/or LCD `pause` and `resume` working correctly
- Tested with Pronterface
- It pauses BUT doesn't send the printer in pause position, and so it is not possible to `resume` from LCD menu
- I guess some Macros can fix that.
- Repetier Host/Server documentation shows that it should work. Not tested.
Could save 56 bytes in first step and additional 38 bytes adding `MSG_PAUSE_PRINT` to messages.c/.h
Updated `lang_en*.txt`
@todo Polish translation is 19 characters long (it still fits) BUT should be corrected to 18 chars.
- Start saving instructions as the whole PR was >1KB long.
- It turned out the compiler was unable to understand the core skipping
cycle and an ASM version had to be used.
- Add seekSet aware of the G-code filter
This is an extension/optimization of PR #2956.
It uses the cached 512B block buffer to avoid heavy-weight read() in SdBaseFile.
Even though this principle allowed the AVR to skip ~600KB of data within ~5 seconds,
the impact on code base is huge, especially into well proven and long-term stable
parts like reading a file from the SD card.
The sole purpose of this PR is to show/verify the possibility of the AVR CPU
in relation to adding thumbnails into MK3 G-codes.
Moreover, this PR shall not be merged unless the missing/commented features
are restored - especially file seeking and M84 search.
PFW-1175
Farmers request having the Change filament menu item always visible in
the main menu and located after the Live Adjust Z (which disappears
after the first few printed layers).
- remove the UI and related stuff to setting a farm number (the
communication protocol must remain intact)
- remove confirmation after print finished ("Print OK")
Both requests are highly welcome, since they allow for lowering the code
size by >1KB
PFW-963, PFW-927
- Changed DETECT_SUPERPINDA to SUPERPINDA_SUPPORT as on miniRAMo the thermistor readings below 30°C
aren't accurate egnough to determine if SUPERPINDA is connected or not
- Add LCD toggle menu Settings -> HW Setup -> SuperPINDA [Yes/No] to overwrite SuperPINDA detection
- If EEPROM_PINDA_TEMP_COMPENSTATION is empty = 0xff then detect SuperPINDA by checking thermistor
- If EEPROM_PINDA_TEMP_COMPENSTAION is 0 then forec enable for temperature compensation menues and functions
- If EEPROM_PINDA_TEMP_COMPENSATION is 1 then force disable for temperature compensation menues and functions
Preheating already raised Z to avoid scorching the PEI sheet, as does
filament loading/unloading to allow for excess material to be removed.
However, when loading/autoloading/unloading via the LCD with a cold
nozzle the preheating menu is performed before the carriage is raised,
leaving the carriage close to the sheet while heating the nozzle.
Pre-raise the carriage already while waiting, so that the subsequent
move is automagically skipped.
Set bFilamentWaitingFlag only once to perform both the LCD
initialization and raising to the appropriate height.
Should fix#2761
* Add missing translations
* Add missing CZ and IT translations
* Update CZ, FR, IT, ES translations
CZ thanks to @DRracer
FR thanks to Carlin Dcustom
ES tried myself
IT thanks to @wavexx
Only missing is PL
* Improve wording +change keys
* Add missing PL translations
* Fix copy paste error in Italian
fix double translations
* Make PL translation shorter
* Fix some length issues and capital letters
* Fixed again translations length issues
updated po files
* Update FR translation - thanks @awenelo
* Fix execution of lang-check.py
- Make lang-check.py executable
- Execute directly instead of specifying the python interpreter manually
("python" is no longer available on Debian, and would default to
version 2 prior to that despite being written for python 3)
* Fix permissions of translation files
Co-authored-by: D.R.racer <drracer@drracer.eu>
Co-authored-by: Yuri D'Elia <wavexx@thregr.org>
Factor-out MIN/MAXTEMP [BED/AMB] out of the error message, which is now
built at runtime instead.
Introduce two missing ultralcd functions lcd_setalertstatus and
lcd_updatestatus to handle regular strings.
246272 -> 246084 = 188 bytes saved
There is no known purpose of this call.
lcd_temp_calibration_set() is switching on/off pinda temperature compensation from LCD settings menu (this is called "Temp. cal." on LCD).
st_current_init() does nothing on Einsy board, it enables and sets motor current selecting outputs on Rambo board (it used to be called digipot in history)