Robert Pelnar
8b66258745
Pin number correction (TACH_0)
2017-07-01 19:33:56 +02:00
Robert Pelnar
4f9a8147a4
renamed EINY 0.1a to EINY 0.3a
...
added EINY 0.4a
changed jerk (optimized for MK3 silent mode)
2017-07-01 17:28:32 +02:00
Robert Pelnar
f6a8e1df9d
TMC2130 + software SG homing + LF lineendings + tmc2130 debug M-Codes
...
M910 - tmc2130_init
M911 - set holding currents
M912 - set running currents
M913 - print currents
2017-07-01 12:39:16 +02:00
PavelSindler
43d696659f
3.0.12-RC2 sync
2017-06-29 18:35:43 +02:00
PavelSindler
0578ea527e
fan speed check initial version, selftest updated
2017-06-28 14:24:45 +02:00
michalprusa
fd2a1f1df4
Resolution setting fixed
2017-06-17 20:54:59 +02:00
michalprusa
6f3c28c4a7
Filament sensor PAT9125 implemented
2017-06-17 20:40:22 +02:00
michalprusa
21177476ac
StallGuard homing implemented, working
2017-06-17 16:58:36 +02:00
michalprusa
3e642d61cb
Stepper Y inverted, current lowered.
2017-06-17 15:58:26 +02:00
michalprusa
c83b1833bc
Johhny Firmware sync
2017-06-17 15:42:48 +02:00
michalprusa
1224705edc
Added EINY config
2017-03-24 20:16:29 +01:00
michalprusa
cabaec95c8
EINY implementation
2017-03-24 20:16:03 +01:00
michalprusa
3faef75a0d
3.0.10 sync
2017-03-24 19:47:50 +01:00
bubnikv
99ae9707de
Fixed a missing SD card error on start up, if the setup was blocked
...
by some dialog for an extended period of time.
Increased version to 3.0.8 final.
2016-09-01 16:52:46 +02:00
bubnikv
fe61647e68
Multi screen messages will display a "next page" indicator
...
if a next page follows.
2016-09-01 15:14:55 +02:00
bubnikv
50a0ca8519
Italian translations.
2016-09-01 14:10:41 +02:00
bubnikv
25024d8975
Added Spanish translations.
2016-09-01 14:07:27 +02:00
bubnikv
163db2f362
Fixed a bug in the optimized fixed point planner.
2016-09-01 13:31:50 +02:00
bubnikv
25b4675823
Updated Polish texts.
2016-09-01 13:13:21 +02:00
bubnikv
29cb4b2b5d
Removed the non-working pressure advance feature.
...
Improved accuracy of diagonal moves by oversampling the path discretization.
Accelerated the planner by rewriting time critical routines from floating
point to fixed point arithmetics.
2016-09-01 13:09:56 +02:00
bubnikv
930ed11e90
Updated texts.
2016-09-01 11:19:32 +02:00
bubnikv
b470e103dc
Reset live adjust on XYZ calibration.
...
Disable timeouts in the XYZ/Z calibration.
Don't modify feed rate multiplier during the XYZ/Z calibration.
Support multi screen messages in the XYZ/Z calibration - "move the Z carriages up" step.
Support up to three lines in the XYZ/Z calibration messages.
Added a new message "Measuring reference height of calibration point xx of 9".
Changed the "move the Z carriages up" message to suggest rotating the knob.
Changed the "live adjust not set" message to reference the manual chapter and section.
Remove debugging serial line output on Z calibration.
2016-09-01 10:44:24 +02:00
bubnikv
26405ee16f
Syncing with 3.0.7 public
2016-08-31 17:12:05 +02:00
michalprusa
307d17422d
3.0.6 sync
2016-08-11 10:42:53 +02:00
michalprusa
30f0528aba
Initial commit
2016-07-22 15:28:01 +02:00