Robert Pelnar
546314fda7
Removed debug messages from serial comunication (octoprint...).
...
build 137b
2017-12-27 20:29:24 +01:00
PavelSindler
d7db407f32
xyz cal.: add delay_keep_alive messages to reset watchdog (LS optimization method takes more than 4s in some cases)
2017-12-05 13:16:59 +01:00
PavelSindler
ba1bb4aea3
whitespace
2017-11-22 19:18:32 +01:00
PavelSindler
6d0574dd0f
changed Y_MIN and probe points coordinates
2017-11-22 19:13:34 +01:00
PavelSindler
6bd221ad3b
Y distance between nozzle and PINDA corrected
2017-11-22 16:07:03 +01:00
PavelSindler
fbbcc27f1a
X max lowered to 250, XYZ/Z calibration: Z top coordinate changed, changes in xyz cal. because of stell sheet, still not final version
2017-11-12 11:30:06 +01:00
PavelSindler
c36b7be90c
SUPPORT_VERBOSITY initial version
2017-11-07 11:36:41 +01:00
PavelSindler
c4d7b801b9
Initial version. XYZ cal works, but bed ref. points coordinates must be checked.
2017-10-27 16:12:37 +02:00
Robert Pelnar
480838a0a1
Fixed homing (mbl and babystep - crashdetection recovery work fine now).
2017-09-23 16:35:01 +02:00
PavelSindler
6eb57da770
fan check can be turned off from support menu, saving parameters to eeprom with offset and different levels, fan kickstart,2nd heatbed version, fans check modified
2017-09-21 15:20:02 +02:00
Robert Pelnar
683784c4c7
PAT9125 I2C, hardware SG homing
...
separate pin configuration file for each board
changed board codes:
RAMBO =100, MiniRambo1.0 =200, MiniRambo1.3 = 203, Einy03 =303, Einy04 =304
2017-08-17 15:23:34 +02:00
michalprusa
3fdb630c42
Mesh bed leveling calibrated to new MK42 24V heatbed (rev 0.3b)
...
Increased currents in Z and E axis
Decreased stallguard sensitivity
E axis microsteps changed to 64
2017-07-06 20:40:56 +02:00
PavelSindler
43d696659f
3.0.12-RC2 sync
2017-06-29 18:35:43 +02:00
michalprusa
3faef75a0d
3.0.10 sync
2017-03-24 19:47:50 +01:00
bubnikv
b470e103dc
Reset live adjust on XYZ calibration.
...
Disable timeouts in the XYZ/Z calibration.
Don't modify feed rate multiplier during the XYZ/Z calibration.
Support multi screen messages in the XYZ/Z calibration - "move the Z carriages up" step.
Support up to three lines in the XYZ/Z calibration messages.
Added a new message "Measuring reference height of calibration point xx of 9".
Changed the "move the Z carriages up" message to suggest rotating the knob.
Changed the "live adjust not set" message to reference the manual chapter and section.
Remove debugging serial line output on Z calibration.
2016-09-01 10:44:24 +02:00
bubnikv
26405ee16f
Syncing with 3.0.7 public
2016-08-31 17:12:05 +02:00
michalprusa
307d17422d
3.0.6 sync
2016-08-11 10:42:53 +02:00
michalprusa
30f0528aba
Initial commit
2016-07-22 15:28:01 +02:00