Commit Graph

24 Commits

Author SHA1 Message Date
PavelSindler
ca3ba55ca7 initial version 2018-03-05 00:46:24 +01:00
Robert Pelnar
c5175e97ec Pinout, conditional translation and variant file for MK2 2018-02-21 15:19:34 +01:00
PavelSindler
0c98ec5f6b selftest, max endstops undefined, initialization of extruder fan, y offset from extruder 2018-02-06 17:01:09 +01:00
PavelSindler
c36af887b7 M600 has timeout for nozzle, different procedure for unload 2018-01-15 11:30:28 +01:00
PavelSindler
17d9bb205a selftest tests filament sensor, selftest messages have language variants 2017-12-20 23:40:18 +01:00
PavelSindler
011ebb3675 selftest is checking if fans are swapped, host keepalive messages added 2017-12-14 19:36:32 +01:00
PavelSindler
1c61f2f29c First working version 2017-12-11 11:30:49 +01:00
PavelSindler
26135ea227 all sd sort files: initial version; sorting type switch not added to SD card menu itself 2017-12-10 11:08:50 +01:00
PavelSindler
2170c1bbe7 timeout to status prolonged, no timeout allowed when MSG_WIZARD_RERUN 2017-11-23 15:46:10 +01:00
PavelSindler
5e4236dd2e selftest for axis improved (better code readibility) and no crash triggered 2017-11-16 18:02:11 +01:00
PavelSindler
2199c84ec9 wrapper function for selftest 2017-11-15 16:40:35 +01:00
PavelSindler
eda0c6bd39 english version of xyz: place/remove steel sheet; wait for cooling down removed, 2017-11-13 17:09:26 +01:00
PavelSindler
fbbcc27f1a X max lowered to 250, XYZ/Z calibration: Z top coordinate changed, changes in xyz cal. because of stell sheet, still not final version 2017-11-12 11:30:06 +01:00
PavelSindler
2e68770e62 initial version - messages missing (will not compile) 2017-11-07 16:49:04 +01:00
PavelSindler
d1a065881b fan error: long pause is used during print, resuming print resets error flag; stop print used during heating phase 2017-09-22 20:43:30 +02:00
PavelSindler
a53428835a fan error improvements 2017-09-22 18:22:21 +02:00
PavelSindler
6eb57da770 fan check can be turned off from support menu, saving parameters to eeprom with offset and different levels, fan kickstart,2nd heatbed version, fans check modified 2017-09-21 15:20:02 +02:00
PavelSindler
54ef2936c7 selftest 2017-07-06 13:19:11 +02:00
PavelSindler
43d696659f 3.0.12-RC2 sync 2017-06-29 18:35:43 +02:00
michalprusa
3faef75a0d 3.0.10 sync 2017-03-24 19:47:50 +01:00
bubnikv
b470e103dc Reset live adjust on XYZ calibration.
Disable timeouts in the XYZ/Z calibration.
Don't modify feed rate multiplier during the XYZ/Z calibration.
Support multi screen messages in the XYZ/Z calibration - "move the Z carriages up" step.
Support up to three lines in the XYZ/Z calibration messages.
Added a new message "Measuring reference height of calibration point xx of 9".
Changed the "move the Z carriages up" message to suggest rotating the knob.
Changed the "live adjust not set" message to reference the manual chapter and section.
Remove debugging serial line output on Z calibration.
2016-09-01 10:44:24 +02:00
bubnikv
26405ee16f Syncing with 3.0.7 public 2016-08-31 17:12:05 +02:00
michalprusa
307d17422d 3.0.6 sync 2016-08-11 10:42:53 +02:00
michalprusa
30f0528aba Initial commit 2016-07-22 15:28:01 +02:00