Yuri D'Elia
e010ca8ceb
Fix conflicting extern/inline declarations
...
The functions find_bed_induction_sensor_point_* have conflicting
extern and inline declarations.
These are used outside of the compilation unit only, and thus there's no
point in defining them inline.
This causes a compilation failure at O1 and above, which is strangely
avoided at Os.
2021-02-10 14:50:13 +01:00
PavelSindler
9e0e4198c5
Mesh by 3d-gussner, fixed difference between mbl points coordinates and coordinates used in planner for corrections, mbl settings menu update
2019-03-14 01:52:44 +01:00
PavelSindler
6a864ffbab
G80 parameters configurable via settings menu
2019-03-08 15:43:37 +01:00
PavelSindler
7c187541e1
function for valid points determination improved; simple Z-coordinate estimation; measure all points and use inaccurate Z-coordinate in case that we don't have enought information for counting Z-coordinate estimation
2019-03-05 22:36:30 +01:00
PavelSindler
d9e93e8a77
measurements points moved 10mm to the left; measure only chosen points (e.g. not points affected by magnets proximity)
2019-03-05 20:40:08 +01:00
PavelSindler
e27fdafcec
menu switch - initial
2019-02-28 19:42:09 +01:00
Laurentiu
4835b9b220
7x7 points mesh bed leveling
2019-02-14 10:57:58 +02:00
Robert Pelnar
8409a26594
Live adjust Z - display zero in case of invalid calibration status (same logic in babystep_load and _lcd_babystep)
2018-08-10 19:55:50 +02:00
Marek Bel
329ea199ec
Show measured bed offset from expected position even if not homed. Remove redundant lcd_quick_feedback() calls.
2018-05-10 18:24:49 +02:00
Marek Bel
d6aa149cfa
Conserve 58 bytes of flash by returning by reference.
2018-04-26 16:36:02 +02:00
Marek Bel
ae08788c99
Split lcd_service_mode_show_result screens to separate functions. Make them non blocking. Remove global array distance_from_min, pass it as function return value. Make Support submenus returning to Support menu.
2018-04-26 16:36:02 +02:00
Marek Bel
3abfeb831f
Update documentation of mesh_bed_calibration.cpp.
2018-04-25 12:21:20 +02:00
Marek Bel
9bd4d580d7
Use right calibration point. This change is only formal, as both original and new point have same coordinates.
2018-04-23 20:33:25 +02:00
Marek Bel
cccd8246ab
Fix world2machine(const float &x, const float &y, float &out_x, float &out_y) not using input parameters if only WORLD2MACHINE_CORRECTION_SHIFT is applied.
2018-04-23 20:33:14 +02:00
Robert Pelnar
ac1a56b493
Merge branch 'MK25' into MK3
2018-03-13 20:43:19 +01:00
Robert Pelnar
65a91b366d
New XYZ calibration with image processing
2018-03-13 12:55:35 +01:00
Robert Pelnar
a6f900fd3c
Merge remote-tracking branch 'upstream/MK25' into MK25
...
# Please enter a commit message to explain why this merge is necessary,
# especially if it merges an updated upstream into a topic branch.
#
# Lines starting with '#' will be ignored, and an empty message aborts
# the commit.
2018-03-06 15:11:50 +01:00
Robert Pelnar
480838a0a1
Fixed homing (mbl and babystep - crashdetection recovery work fine now).
2017-09-23 16:35:01 +02:00
PavelSindler
43d696659f
3.0.12-RC2 sync
2017-06-29 18:35:43 +02:00
bubnikv
26405ee16f
Syncing with 3.0.7 public
2016-08-31 17:12:05 +02:00
michalprusa
307d17422d
3.0.6 sync
2016-08-11 10:42:53 +02:00
michalprusa
30f0528aba
Initial commit
2016-07-22 15:28:01 +02:00