PavelSindler
34ba8c3bf7
reset bed level correction only for xyz calibration
2017-01-16 16:24:44 +01:00
PavelSindler
cdeedce58f
fix: only_z changed to onlyZ
2017-01-16 15:13:22 +01:00
PavelSindler
d20adaa8fa
Z calibration dont set preheat values to zero,
...
improved alert meassages in selftest
2017-01-16 13:53:39 +01:00
PavelSindler
975718fc89
reset xyz calibration resets live adjust also
2017-01-15 23:09:42 +01:00
PavelSindler
7abaf4e6a7
Added message translations to all languages, improved homing, changed display when waiting for cooling in xyz calibration, added multiscreen message for E calibration,
2017-01-15 22:11:56 +01:00
Aaron Yourk
bcc0e83d76
Fix up some accuracy issues with PT100 temp sensors in relation to the Rambo v1.3a
2017-01-12 15:49:48 -07:00
Aaron Yourk
7d5affa12e
Add additional debugging information for temerature sensor calibration.
2017-01-12 15:46:17 -07:00
PavelSindler
872ca47795
added defines for min and max steps per unit for E calibration
2017-01-12 16:43:46 +01:00
PavelSindler
aad15877de
added defines for min and max steps per unit for E calibration
2017-01-12 16:42:25 +01:00
PavelSindler
b0566cbb14
Merge pull request #34 from PavelSindler/MK2
...
Improved E calibration, added degree sign when waiting for cooling in…
2017-01-12 13:43:18 +01:00
PavelSindler
a08010c8df
Improved E calibration, added degree sign when waiting for cooling in xyz calibration, removing cooling when calibrating just Z, fixed move_menu_axis
2017-01-11 18:14:42 +01:00
Aaron Yourk
0181a17263
Revert "Rebase to upstream changes."
...
This reverts commit 3afe6d09e2
.
Resolves conflicts with upstream Pull request.
2017-01-09 17:11:47 -07:00
PavelSindler
ea22febb42
added defines for snmm and stack guard
2017-01-09 16:27:44 +01:00
PavelSindler
bfe2f72cf8
added defines for max hotend and max bed temperature for xyz calibration
2017-01-09 14:58:05 +01:00
PavelSindler
fcce374a14
initial version - merging from DEV multicolor
2017-01-09 13:12:39 +01:00
Aaron Yourk
3afe6d09e2
Rebase to upstream changes.
2016-12-31 16:24:33 -07:00
Aaron Yourk
2db00510c2
Add modifications from the Mini Rambo 1.3a header to the Mini Rambo 1.0a header.
2016-12-31 07:20:15 -07:00
michalprusa
2c0e83a785
Factory reset redesigned and added LCD output
2016-12-30 17:16:24 +01:00
michalprusa
87c6d36cf2
Menu redesigned in farm mode
2016-12-30 14:42:02 +01:00
michalprusa
d2bcdec300
Force high power mode when in farm mode
2016-12-30 13:37:07 +01:00
Aaron Yourk
6129c9167d
Make an attempt at resuming previous fan speed when resuming from a paused SD card print via the menu.
2016-12-27 16:43:43 -07:00
Aaron Yourk
d5ce8dfa96
Renamed fpos_t to filepos_t as per Github issue #9 to be more compatible with versions of Arduino newer than v1.6.8.
2016-12-27 15:19:18 -07:00
ayourk
0af1945d5e
Update thermistortables.h
...
Update thermistortables.h to be more in line with the forum post.
2016-12-25 04:20:39 -07:00
Aaron Yourk
ad55674801
Added PT100 bed PID values (copied from extruder PID and untested)
2016-12-25 03:03:33 -07:00
Aaron Yourk
93400ea4e0
Fix ENCODER steps in Configuration.h
...
Add temp tables for the E3D PT100 with Amplifier in thermistortables.h
Make it easier to switch to the PT100 temperature sensor with appropriate PID values for the Extruder.
2016-12-25 02:49:34 -07:00
Michal Průša
e4b7219239
Merge pull request #27 from AndreeeCZ/MK2
...
main: ignore handling of 'N' symbols (line number) when dealing with special PRUSA commands
2016-12-14 16:03:11 +01:00
Andre Sklenar
83dbcc2985
main: ignore handling of 'N' symbols (line number) when dealing with special PRUSA commands
...
Signed-off-by: Andre Sklenar <andre.sklenar@gmail.com>
2016-12-14 15:59:23 +01:00
michalprusa
5169c17d2f
Version increment
2016-12-14 15:12:21 +01:00
Michal Průša
2452e43387
Merge pull request #26 from AndreeeCZ/MK2
...
Add chunk upload to SD card.
2016-12-14 15:01:46 +01:00
Michal Průša
8f3f10765a
Merge branch 'MK2' into MK2
2016-12-14 15:01:33 +01:00
michalprusa
734ca2eb43
Added link monitor to farm mode
2016-12-14 14:59:01 +01:00
Andre Sklenar
16e34501a0
main: remove features that are not complete yet
...
Signed-off-by: Andre Sklenar <andre.sklenar@gmail.com>
2016-12-14 14:49:23 +01:00
Andre Sklenar
c58453a726
main: add chunk write to sd card
2016-12-14 14:38:36 +01:00
michalprusa
977b58269a
Soft factory reset does not reset Live Adjust Z to 0
2016-11-01 17:21:56 +01:00
akukan
6f203c4735
Farm mode error reporting
2016-10-27 15:43:56 +02:00
akukan
2f13563c18
Pre-heat termal runaway check adjusted
2016-10-25 17:06:28 +02:00
michalprusa
54bcd2022d
Added question mark for better understanding.
2016-10-21 19:15:02 +02:00
michalprusa
04b83db0ad
Italian language fan self test messages translated.
2016-10-19 16:46:07 +02:00
michalprusa
3c735786e3
Max endstops pins definition fixed to match pcb layout
2016-10-19 16:04:41 +02:00
michalprusa
ea197360ac
Print fan automatically turns off after stop print
2016-10-19 15:54:48 +02:00
michalprusa
d0e678e1d1
HotFix - Calibrate XYZ and Calibrate Z now prints status messages of next step after confirming that both carriages are all the way up.
2016-10-19 11:58:15 +02:00
michalprusa
0e7b4d3d3c
Firmware version iterated, fan selftest strings ported to all languages.
2016-10-19 09:55:56 +02:00
akukan
8cd558007c
Fan test adjustments
2016-10-13 10:40:15 +02:00
akukan
da5f1f71ea
Fan selftest, error on TR reported via serial
2016-10-11 18:07:27 +02:00
bubnikv
e9f25eba27
Translated MSG_BABYSTEP_Z_NOT_SET into Polish language.
2016-10-10 09:38:43 +02:00
bubnikv
854b79de46
Implemented a calibration flow supporting the new & pre-built machines.
...
Fixed a thermal runaway on heat up.
Increased timeout of live adjust to 90 seconds.
2016-10-07 17:21:06 +02:00
bubnikv
e0bb76032c
Reset live adjust on XYZ calibration.
...
Disable timeouts in the XYZ/Z calibration.
Don't modify feed rate multiplier during the XYZ/Z calibration.
Support multi screen messages in the XYZ/Z calibration - "move the Z carriages up" step.
Support up to three lines in the XYZ/Z calibration messages.
Added a new message "Measuring reference height of calibration point xx of 9".
Changed the "move the Z carriages up" message to suggest rotating the knob.
Changed the "live adjust not set" message to reference the manual chapter and section.
Remove debugging serial line output on Z calibration.
Removed the non-working pressure advance feature.
Improved accuracy of diagonal moves by oversampling the path discretization.
Accelerated the planner by rewriting time critical routines from floating
point to fixed point arithmetics.
2016-09-01 17:05:15 +02:00
akukan
078d883416
Firmware version updated to 3.0.7
2016-08-23 10:27:29 +02:00
bubnikv
77c24aa56e
Improvement in the mesh bed leveling routine: Z-lift before XY to home.
...
Fix of the print stop: Reset mesh bed leveling and baby stepping
on print stop.
2016-08-22 13:02:04 +02:00
michalprusa
e7bc6a0645
Z homing cords reconfigured.
2016-08-21 16:44:45 +02:00