A warning implies something went wrong and (possibly) the user should do
something about it. However, warnings are not always used this way.
For example:
* When a fallback value for a `${..}` reference is used, this shouldn't
produce a warning (or notice) since using fallbacks is not something
bad.
* pulse telling you that it uses the default sink because no sink was
specified also does not warrant a warning (even notice may be too
high).
* Whenever polybar shuts down it produces a "Termination signal
received..." warning. Since there isn't a more proper way to shut down
polybar, it should not produce a warning. Same argument for a
`screenchange-reload`
The github module only authenticate by query string, and this method is deprecated:
https://developer.github.com/changes/2019-11-05-deprecated-passwords-and-authorizations-api/#authenticating-using-query-parameters
There is no reason to remove it before the method stop working, so I've made possible to the user choose which authentication method he will use:
* The parameter token remain unchanged.
* If the parameter user is passed then the module will use the not deprecated method, passing user and token on the body of the requisition. Otherwise the module will use the deprecated method.
Co-authored-by: Lucas <araujo.lucasvale@gmail.com>
Fixes#2002
Adds `format-offline` and `label-offline`
* feat(github): offline label & fixes
* Clear label if there are no notifications and empty-notifications = false
* clang-format
Co-authored-by: Patrick Ziegler <p.ziegler96@gmail.com>
None of the payload fields seem to be used. They were the only place
where EVENT_SIZE was used and why it had to be a macro (no variable
length arrays).
Some people use text modules instead of the `separator` key in the bar
section to better configure the separator (colors, fonts).
Since we disallowed the same module being used multiple times in #1534,
this will now print an error message.
This should help with this a bit.
Ref #1913
A workspace is occupied if it is not active and there is at least one window managed by the WM (`_NET_CLIENT_LIST`) that has set `_NET_WM_DESKTOP` to that workspace.
The behavior when `_NET_WM_DESKTOP` is not set is not yet clear but this is unlikely to happen since most WMs will position windows on some desktop.
Closes#874Fixes#1444Fixes#1033
* Set Desktop OCCUPIED if a window moves there
This covers more of an edge-case. I did this first by accident, it might
vanish later on.
* Replace tracking change of WS with currently used WS
* Untrack occupied workspaces
* Track windows and their desktops in pairs
* Match type of occupied_desktops with current_desktop
Because the index needs to be matched later on, type mismatches would be non-ideal.
* Recreate the occupied desktops everytime and remove duplicates
* Readd support for moving windows to other desktops
* Use less characters to empty the vector
* Rename variable storing the desktops
* Recount windows on every occasion
This alone simplifies the management and the lookup for occupation of a
workspace
* Keep track of number of windows in every workspace
* Add debugging output that shall be removed before merging
* Remove obsolete TODO
* m_client_list should always be diff'd, since the desktop may change
Therefore we update the desktop-count tally every time the client_list
changes. It may just be a desktop-change without a change of
clients.size()...
* Add more logging-spam to understand window/desktop lifecycle
* Lock event-handler to serialize handling of events
* Fix occupied workspace counting and change to bool array
Also, performance improvements when diffing new and old client lists
* Fix crash when all clients are removed
* Conform to linter and styleguide
* Shorten conditional as it is standard enough
Since this only guards against 0-divisions, it can be shortened
without risking too much confusion down the road.
* Guard against multiple threads accessing and modifying data
Fixes#1444
Modification of internal data happens through the handle-method, while
the build-method tries to access the data structures for display. Since
some modifications clear e.g. the m_viewports, references may become
invalid between looping over them an accessing them.
The mutex should guard against this simultanuous access.
* Do not 'adopt_lock', because calls come from very different threads
To my understanding, adopt_lock has some dependency on the mutex-ownership. Since
the lock is once called from the inside (in handle) and once from the outside (in
build), there might be a problem. After brief testing, the segfaults happened fewer
times.
See #1444
* Also listen to _NET_WM_DESKTOP
In order to move a window from one desktop to another, it is sufficient
to set the desktop-property of that window. xmonad fires a lot of events
in the case of moving a window, herbstluftwm only updates the
_NET_WM_DESKTOP-atom of the window.
This change reloads the clientlist in order to correctly set the
desktop state "occupied".
* Describe need and use of mutex
It might be possible to relieve the guard in xworkspaces_module::handle,
but I am unsure about this. Since xmonad emits a lot of events on almost
every minor change, I would let the guard keep its post, avoiding
race-conditions in event-handling.
* Give temporary variables better names
* Clarify purpose of loop
About 80% of this comment are taken from
https://github.com/jaagr/polybar/pull/882#discussion_r255317363
* Remove merge-remainder
* Use a simpler method to list occupied desktops.
Co-authored-by: Jérôme Boulmier <jerome.boulmier@outlook.fr>
* Document m_clients field
The %{PR} tag is introduced for this. It resets all colors as well as
the activation of the underline and overline and font.
This has become necessary because we don't track what raw tags a user
injects into the formatting string and otherwise their raw tags could
bleed through.
This doesn't touch action tags because even before raw action tags
weren't being tracked. Action tags also have the requirement that they
have to be used in pairs, so closing them prematurely could break things
(for example with click actions for the entire bar)
Displays real percentage instead of being set to 100 if percentage > full-at
* battery: added percentage_raw token, which ignores full-at
* battery: current_percentage returns raw, added clamping function instead
* battery: clamp percentage used by build()
Made clamp_percentage() const to allow its usage inside build()
* battery: read and return percentage in one line
* `layout-icon-*` list that maps layouts to icons.
* `indicator-icon-*` list that maps indicators to off and on icons
* `label-indicator-off`
* `label-indicator-on` which replaces the now deprecated `label-indicator`
* `label-indicator-[on|off]-*` for each indicator. Overrides `label-indicator-on` and `label-indicator-off`
Fixes#1558Closes#1048
* add icon support for xkeyboard layouts
* removed unneeded #include
* add sperate %icon% token that can be used in <label-layout>
* removed unneeded #include
* added caps lock indicator (was mentioned in wiki, but not actually implememnted) and support for indicator icons
* a few more fixes to make sure existing user configs are not broken
* ready to go
* Added an option to replace xkb indicator names
* Added labels for each indicator state
* Removed print left on accident
* Fixed review comments
* Update src/modules/xkeyboard.cpp
Co-Authored-By: Gilnaa <gilad@naaman.io>
This adds a new label in the bspwm module `label-marked`
This flag for focused nodes of a focused desktop was introduced in [1]
and released with bspwm 0.9.4
It adds the `M` flag to `G` type items in bspwm's report format
Resolves#1552
[1]: d0138af475
Now all the tokens in the memory module also have ramp and bar counterparts.
These can be used exactly the same as `bar-used` and `ramp-used`, they are named `<bar-swap-used>`, `<bar-swap-free>`, `<ramp-swap-used>`, and `<ramp-swap-free>`
The repeatone button doesn't influence repeating behaviour at all, so
the name is misleading.
This deprecates icon-repeatone for now, until we can completely remove
it
Fixes#1279
expand-right defaults to true to preserve the current functionality
If set to false, the items in the menu will be added to the left of the
toggle label (instead of the right side)
Should resolve the issue discussed in #655
When focusing a desktop with the urgent flag, two events are received
from `bspc` simultaneously, separated by a newline character.
This was not handled correctly and the second event was discarded causing
the urgent style to be removed, but the focused style would remain on the
previously focused desktop.
This fixes the problem by handling any number of events that arrive at the
same time (separated by newlines).
Added support for fuzzy matching workspace names when assigning icons.
This feature is enabled/disabled through a new option, 'fuzzy-match'.
It is disabled by default.
This removes the spacing tinkering when parsing format specs.
The following example uses the old behavoir:
format-test = <label-foo> <label-bar>
format-breaks = <label-foo><label-bar>/<bar-test>
`format-test` would replace all occurences of ' ' with the
a space string with defined `spacing` as its width. `format-breaks` would
not validate as the tags where split with ' ' as delimiter.
All that nonsense has been removed and each tag is extracted as is.
The `spacing` parameter can still be used to apply N extra whitespaces
between the tags, but it is now 0 by default.