Only modules can now be action handlers.
This also slightly simplifies the controller because we don't need to
keep track of input handlers, we can just use the module list.
The next action should always select the next workspace, the same for
prev.
reverse-scroll should be directly used when setting the scroll actions.
This changes the behavior of `prev` and `next` actions in the i3 and
bspwm module.
But I don't think the impact will be significant and the old behavior
was misleading anyway.
Some actions have data attached (e.g. xworkspaces-focus=N), the
forwarding logic now matches the keys in the legacy_actions map as
prefixes and everything afterwards is considered additional data and
appended to the new action string.
All modules now expose their actions as public static constants
Issues: The menu module no longer closes when an item is clicked (before
it would intercept any executed command and look if it matches one of
its exec commands)
All the information about which action has to be delivered to which
module is kept in once place to make cleanup easier once the deprecated
actions are removed.
Right now only the date module is added as a proof of concept.
This allows us to identify module by their type and it is also better to
store the module type as part of the module instead of having it
hardcoded in factory.hpp
Action strings now have the form '#MODULE#ACTION'
For example to trigger the action 'toggle' in the 'module/date' module
one would now use '%{A1:#date#toggle:}'
With this action strings can now be uniquely assigned to one module.
Fixes#1172
Before the time difference between two measurements was always an
integer number, so for intervals < 1, you would always get 0 and for any
other non-integer interval you would get skewed results.
ramp-0 is used for everything <= base-temperature and ramp-N is used for everything >= warn-temperature
* [Temperature, Ramp] fix wrong icon for temperatures near base and warn temps
* [Temperature, Ramp] fix wrong icon for temperatures near base and warn temps
* Fix minor error
* explicitly check percentage in get_by_percentage_with_borders
* Fixed silly error
* Prioritize battery full-at over state
The `full-at` option should take priority
over the charging state of the battery.
Closes#1622 (issue for Thinkpad laptops)
* Remove typo from clamp_percentage
Some devices can have "amdgpu_bl1" or "amdgpu_bl2", but the code hardcoded in the value "amdgpu_bl0". This change tests based on the first characters: "amdgpu_bl".
If an input is enqueued as a response to an input, the new input will be
swallowed because it will likely be enqueued less than 30ms after the
original event.
This is not something that is an issue right now but it is required to
finish #1907 where, in order to close the menu after a click, the menu
module gets an exec action that closes the menu and adds a command to
the event queue.
The setting also isn't too useful since it will just break polybar input
handling if inputs arrive too fast instead of (possibly) slowing down
the bar.
Before the module would just try to evenly distribute desktops
(workspaces) among the viewports.
But since `_NET_DESKTOP_VIEWPORT` actually maps desktops to viewports,
we can use that information to assign workspaces to the right viewport.
Fixes#1849Fixes#1764
It is useful for people to see what config file polybar loaded.
For debugging font issues people almost always need to check what fonts
polybar loaded, for that they need to run polybar with info logging. Now
this information is always provided. This requires an update in the font
wiki page.
A warning implies something went wrong and (possibly) the user should do
something about it. However, warnings are not always used this way.
For example:
* When a fallback value for a `${..}` reference is used, this shouldn't
produce a warning (or notice) since using fallbacks is not something
bad.
* pulse telling you that it uses the default sink because no sink was
specified also does not warrant a warning (even notice may be too
high).
* Whenever polybar shuts down it produces a "Termination signal
received..." warning. Since there isn't a more proper way to shut down
polybar, it should not produce a warning. Same argument for a
`screenchange-reload`
Before it would only reload if the size changed and even that was
reliable since the method relied on the order of the monitor list.
Now if the monitor list differs in any way (pos, dimension, primary,
output, name) a reload is issued
Because of how monitors are removed inside the loop and depending on the
monitor order a cloned monitor may be assigned a width of 0 but is never
actually removed resulting in polybar saying the bar is out of bounds
Fixes#1794
Removing monitors is not really necessary when selecting the monitor
where to render the bar or choosing the backlight. Since both monitors
occupy the same coordinates rendering can be done on both and it's
better to give people felxibility for the backlight.
Fixes#1191
Premature optimization that tried to cache monitors but the cache did
not take into account the parameter values.
The call `get_monitors(..., ..., false, true);` would get all connected
and unconncected monitors a subsequent call
`get_monitors(..., ..., true, false);` would get back the same list of
monitors even though it requested only connected monitors.
Additionally `get_monitors` is never called periodically so the
optimization really didn't help much.