1
0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2024-11-29 23:07:42 +00:00

📝 Some settings units

This commit is contained in:
Scott Lahteine 2023-10-06 16:08:30 -05:00
parent 273cbc6871
commit 91ab18d1d2
2 changed files with 19 additions and 19 deletions

View File

@ -665,7 +665,7 @@
//#define MPCTEMP // ** EXPERIMENTAL ** See https://marlinfw.org/docs/features/model_predictive_control.html
#define PID_MAX 255 // Limit hotend current while PID is active (see PID_FUNCTIONAL_RANGE below); 255=full current
#define PID_K1 0.95 // Smoothing factor within any PID loop
#define PID_K1 0.95 // Smoothing factor within any PID loop
#if ENABLED(PIDTEMP)
//#define PID_DEBUG // Print PID debug data to the serial port. Use 'M303 D' to toggle activation.

View File

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2413,7 +2413,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2611,7 +2611,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK