1
0
mirror of https://github.com/MarlinFirmware/Marlin.git synced 2024-11-29 23:07:42 +00:00
Commit Graph

8377 Commits

Author SHA1 Message Date
Giuliano
7284488da3 [1.1.x] fix bltouch homing (#11380)
Partially revert. Seems to solve the issue, but one report says G29 still fails.
2018-07-27 18:29:26 -05:00
Scott Lahteine
cab2e0877e Update DELAY_10US 2018-07-26 20:21:50 -05:00
bleughb
b6f24992ee [1.1.x] Update fastio_1280.h pin mapping comments (#11374) 2018-07-26 05:19:05 -05:00
Scott Lahteine
c30f636d22
Improve drivers.h macros (#11372) 2018-07-26 05:10:11 -05:00
Giuliano
2f76ec5c6a [1.1.x]-different-bltouch-init (#11358) 2018-07-26 05:03:39 -05:00
Scott Lahteine
56fbe3361b
Ensure ADC conversion is complete before reading (#11370)
Co-Authored-By: gloomyandy <andy-git@gloomy-place.com>
2018-07-26 03:58:33 -05:00
vitekn
b5ed4a1a8c Fix thermistor type in Anet A6 config (#11346)
I have Anet a6 and my thermistor is NTC 3950. If the default is 5 (ATC Semitec 104GT-2) it gives overheat upto 330 degrees (real) instead of 250 (displayed). I don't know for sure if all the A6 have such thermistor but I think it's safer to have underheat than overheat. And 3950 looks more spread among A6 searching on Internet. The same is true for the bed though it has small difference at the beginning of scale, actually +-2 degrees.
2018-07-26 02:03:30 -05:00
Scott Lahteine
2af06b82b4 Specify some extra CR-10S pins 2018-07-25 18:18:33 -05:00
Scott Lahteine
637489ae17 Tweak some SoftPWM code 2018-07-25 18:16:33 -05:00
Scott Lahteine
349cf3ee5a Sync enqueue_and_echo_command with 2.0.x 2018-07-25 18:06:31 -05:00
Giuliano
e5b928f574 [1.1.x] Typo fix (#11366)
Typo fix
2018-07-25 18:00:28 -05:00
Scott Lahteine
7bad507d70 Simplify stepper driver config 2018-07-25 03:02:12 -05:00
Scott Lahteine
6d6bdc6517 Add *_DRIVER_TYPE to example configs 2018-07-25 02:39:16 -05:00
silentninja1
57ce81f067 [1.1.x] Fix LCD axis move E index (#11328) 2018-07-25 02:21:05 -05:00
Scott Lahteine
ed0e72bf44 Fix spelling in configs 2018-07-24 21:02:22 -05:00
silentninja1
060e7a3565 Silentninja1 idex crash fix (#11329)
* Move home all axis prototype to allow access from UBL.h

* Remove home all axis command as it exists in marlin.h now

* Reverse order of tool change and home

Race condition causes E0 carriage to move on E1 commands and crash into parked head if order is reversed. Needs more research into permanent fix, but this will prevent damage to machines in the meantime.
2018-07-24 14:44:50 -05:00
Scott Lahteine
3bbb121e7d Tweak some Max7219 code 2018-07-19 18:51:35 -05:00
Scott Lahteine
d1590fec3e
Merge pull request #11308 from thinkyhead/bf1_manual_probe_start_z
[1.1.x] Manual Z Start Height
2018-07-19 18:26:51 -05:00
Roxy-3D
6c62b0e263
Change Max7219_idle_task() to use columns if Y-Axis has 16 LED's (#11317) 2018-07-19 16:59:38 -05:00
Scott Lahteine
221e8bbb05 Add MANUAL_PROBE_START_Z to example configs 2018-07-18 21:50:18 -05:00
Scott Lahteine
888774cbc3 Add MANUAL_PROBE_START_Z for manual probing 2018-07-18 21:50:18 -05:00
Scott Lahteine
db057eb453 Fix tool_change call in UBL G29
Fix #11279, #11252
2018-07-18 20:35:14 -05:00
Scott Lahteine
5ce312f158
Merge pull request #11305 from thinkyhead/bf1_power_loss_pin
[1.1.x] Add support for power loss detect pin
2018-07-18 20:13:47 -05:00
Scott Lahteine
389f2ac81f planner.synchronize at start of tool_change
See https://github.com/MarlinFirmware/Marlin/issues/10949#issuecomment-398540498
2018-07-18 20:09:39 -05:00
Scott Lahteine
7321f30ac0 Add POWER_LOSS_PIN support 2018-07-18 19:58:06 -05:00
Scott Lahteine
46b0e054b1 Add POWER_LOSS_PIN to example configs 2018-07-18 19:58:06 -05:00
Giuliano
9d0627d66c Make GCodeParser::debug static (#11294) 2018-07-17 23:38:39 -05:00
Scott Lahteine
6024ffedd9 Improve Malyan progress / feedrate
Co-Authored-By: J.C. Nelson <xc0000005@users.noreply.github.com>
2018-07-17 19:33:57 -05:00
Scott Lahteine
7e648f3721 Add card.longest_filename, more lcd_strlen updates 2018-07-17 19:33:57 -05:00
Scott Lahteine
036f25e159 More lcd_strlen updates 2018-07-17 18:17:19 -05:00
Scott Lahteine
17e1eec21e Make sure linear units are initialized
Based on #11295

Co-Authored-By: Giuliano <gmagician@users.noreply.github.com>
2018-07-17 17:20:57 -05:00
Roxy-3D
58775cc694
Don't display M421 values for UBL at startup
It takes 20 seconds to display the mesh values at startup...   If we are going to display this information at startup, we should find a more terse way to do it.   Perhaps displaying an entire row of the mesh at a time makes sense?
2018-07-17 17:17:09 -05:00
Scott Lahteine
fbc3fdb490 LCD strlen functions like 2.0.x 2018-07-17 15:25:58 -05:00
Scott Lahteine
756080fcca Followup to floats patch 2018-07-17 15:24:33 -05:00
Giuliano
e6801ff84a [1.1.x] Fix change filament (#11268)
Prevent crash, on filament change, when printer is not homed
2018-07-16 21:48:45 -05:00
Roxy-3D
bc961220b7
Change Max7219_idle_task() routines to use single line if X-Axis has 16 or more LED's
Change Max7219_idle_task() routines to use single line if X-Axis has 16 or more LED's

This gets bugfix_1.1.x at parity with https://github.com/MarlinFirmware/Marlin/pull/11285 when it gets merged.
2018-07-16 19:23:59 -05:00
kaimimue
256f76d35e Fix Vellemann K8400 Configuration (#11258)
The maximum movement is 180mm for Velleman K8400.
An offset of `Y_MIN_POS` violates an assertion in `SanityCheck.h`.

Code tested on Vellemann K8400 with Dual Extruder.
2018-07-13 23:15:00 -05:00
Giuliano
1067c43107 [1.1.x] fix kill printer (#11261)
This will fix kill message on dual printer with 0 alignment offset
2018-07-13 23:13:29 -05:00
Scott Lahteine
d60b2e5ba8
Merge pull request #11233 from nightgryphon/multiprobe-z-up
[1.1.x] Shorter Z raise between multiple probes
2018-07-12 22:44:25 -05:00
Scott Lahteine
cb0777dbeb
Merge pull request #11248 from thinkyhead/bf1_tmc_unify_param_i
[1.1.x] Unify "I" parameter for M906,M912 etc.
2018-07-12 22:31:26 -05:00
Scott Lahteine
8f110190eb Add Z_CLEARANCE_MULTI_PROBE to example configs 2018-07-12 22:27:06 -05:00
nightgryphon
54adf6f52d Shorter Z up move between multiple probing attempts
For some probes like micro switches the full Z clearance raise between
probing attempts is not required while bigger Z clearance between probe
points is still needed to avoid clamps. The shorter Z raise within
multiprobing same point significantly increase probing speed and the whole
auto level process.
2018-07-12 22:27:06 -05:00
Clifford Roche
3b5c81b84a [1.1.x] Validate that X/Y_PROBE_OFFSET_FROM_EXTRUDER are integers (#11255) 2018-07-12 21:22:59 -05:00
Scott Lahteine
d8331d97d6 Unify M91x parameter I meaning, simplify reports 2018-07-11 20:31:40 -05:00
Scott Lahteine
5cddfce0ee Endstops::report_state => event_handler 2018-07-11 19:47:25 -05:00
Aaron Griffith
5f587126b9 Loosen static assertion guarding overflow in SCAN_THERMISTOR_TABLE (#11240)
Bisect search merged in #10882 actually works fine for thermistor
tables with up to 255 entries with no overflow, due to C++ integer
promotion rules.

Closes issue #11220.
2018-07-11 16:42:23 -05:00
Roxy-3D
39b3e4c501
Support for multiple Max7219 units in a chain (#11226)
* Support for multiple Max7219 units in a chain

I'll move this support over to bugfix_2.0.0 in the next few days.   And
then look at updating the Max7219_idle() routine to make use of multiple
units in a chain.

* spelling correction
2018-07-08 17:35:58 -05:00
Roxy-3D
fae2929b6b
Resolve issue where user can't edit mesh 2018-07-08 14:39:08 -05:00
Scott Lahteine
ccb225f43a
Float maths updates for 2.0.x parity (#11213)
Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-07-06 21:44:33 -05:00
Scott Lahteine
fc9f4ce2c0 Fix missing quote in language list
Co-Authored-By: p3p <p3p@p3psoft.co.uk>
2018-07-04 13:40:18 -05:00